|
| 1 | M&L for premix bituminous macadam mixed with paving bitumen @ 4% binder contents any penetration laid/rolled and campacted to required gradient and camber (Consolidated thickness n.exc 75mm) with 8 to 10 Ton power roller complete all as specified and directed. |
| 2 | M&L for applying evenly a prime coat of Cationic Bitumen Emulsion SS1 confirming to IS: 8887 at a rate o application of 0. 7-1 kg/sqm on surface of WMM/WBM as specified in Table 500-3 of MoRTH specification for road and bridge works 2013, using mechanical sprayer including preparation of road surfaces by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc complete all as specified and directed. |
| 3 | M&L for Repair to potholes any depth, not exc 1 sq m each including sweeping free from dust and mud, or water, scoring sunken surfaces in roads, paths, etc. cutting around edges to at least 25 mm in depth, making good by applying tack coat @ 5 kg per 10 Sqm, putting in premixed bituminous macadam, well rammed and sealed with binder @ 9.8 kg per 10 Sqm, Vg10/Vg30 blinded with 0.09 cum of stone chippings, 6.3 mm size and again well rammed (including supply of premixed macadam, binder and chippings). depth of potholes exc 30 mm complete all as specified and directed. |
| 4 | Preparing the black top surface of roads by brushing with wire brushes for removing caked mud etc, sweeping with brooms and finally fanning the cleaned surface with gunny bags to remove all loose dirt etc and Applying evenly a tack coat of Cationic Bitumen Emulsion (RS-1) over SDAC/SDBC/BM conforming to IS: 8887 at a rate of application of 0.2-0.3 kg/sqm on bituminous surface as specified in Table 500-5 of MaRTH specification for road and bridge works 2013, using mechanica sprayer after cleaning of existing surface as specified and directed. |
| 5 | M&L for Bituminous premix asphaltic semi dense concrete 30mm consolidated thickness with 5% binder paving bitumen (Viscosity grade VG-30) content by weight of total mix, rolled and compacted to required camber and gradient, and laid with mechanical paver and rolled to a uniform smooth surface with 8 to 12 tonne power roller and compacted to required camber and gradient complete all as specified and directed. |
| 6 | M & L for preparing bituminous surfaces of road and marking 2.5mm thick centre lines, stop lines, dashes, arrows etc. and the like, 10cm wide on roads pavements with hot applied thermo plastic road marking paint of approved colour confirming to BS 3262-1989 with special applicator machine all as per manufacturers instruction complete all as specified and directed. |
| 7 | S&F in repairs Bi-Directional Reflective type road solar studs (125mm x 125mm x 25mm) illuminated red both sides of rectangular / square shape made out of thermoplastic body fixed on road with bitumen adhesive as per manufacturers instructions having abrasion resistance ceramic coating and reflective surface complete all as specified and directed. Make : 3M, OSCAR or its equivalent as approved by GE. |
| 8 | S&F in repair cat eye solar reflective type of metal body alloy of size 90mm x 100mm x 20mm with PAMA striplens reflector of model No. DA 972.0 fixed with and incl MS stud of suitable size as per manufactures instructions. complete all as specified and directed. |
| 9 | Supply and fixing in repair metal tubular dealineator made out of ABS round body fitted with 2 Nos 65 mm dia highly reflective reflectors made out of PMMA and mounted on 45/50 mm dia mild steel pipe of 600 mm height duly powder coated and thermo plastic elastomer 3 bands of green, red and yellow reflector radium tape of 25 mm wide strips with anti theft steel net for reflector protection including embedding in PCC 1:2:4 (150x150x300mm) type B1 complete all as specified and directed |
| 10 | Supply and fix in repair solar cat eye aluminum alloy shall (100% water proofing design according to 65) of size 125mm x 125mm x 25mm (shank 65mm) of high efficiency Mono rystafie solar panel 2.4V/ 0.3 watt one NI-ed rechargeable battery (1.2V/ 1600MA) consisting of super bright LED with 10,000 to 18,000 mcd completed as per manufactures instructions etc. complete all as specified and directed |
| 11 | S&F in repairs yellow and black plastic speed bump made up of ABS materials to highly reflective reflector moulded in EMMA material welded with ABS base plate through ultrasonic welding processes of size 350mm length and width of 263mm with working width of 250mm, height 53mm and weight appx 1200gms complete all as specified and directed. |
| 12 | S&F in repair retro relective direction and place identification sign boards by providing and fixing of new retro reflectorised cautionary, mandatory and informatory sign as per ASTM D 4956-04 made of high intensity grade Microprismatics sheeting Type IV fixed over 4.0mm thick Aluminium composite panel of size 1200mm x 900mm fixed to frame of stainless steel hollow square section of area not less than 9 sqr cm with necessary fixing arrangementns and having vertical post not less than 50mm round buffed stainless steel of grade SS 304 with half round cap, minimum thischness of SS tube/post will not be less than 3mm thick, wherever required back support on appropriate height as directed by Engr in charge. The message symbol and numerals shall be of 3M high intensity micro-Prismatic Grade Retro reflective sheeting or equivalent (message and numbers as per approved by GE of any number of lettes and numbers) with and including complete foundation work like excavation,PCC (1:2:4) type B2 (using 40mm grade stone agg) in post filling, removal, RFR and eracion at site as specified by Engr-in-Charge and directed. |
| 13 | M&L for 8-10mm thick heavy duty outdoor indura matte finished ceramic tiles in any colour, size & design etc for parking, footpath, pedestrian etc and similar location, of size 400x400, jointed and pointed in neat cement slurry complete all as specified and directed. |
| 14 | M&L for 20 mm thick screed bed or bedding layed for tiling work (parking tile, foothpath tile, chequered tile etc) in cement mortar 1:6 complete all as specified and directed. |
| 15 | M&L cement concrete 1:3:6 type C-2 (using 40mm graded stone aggregate) of 75 mm thick in floors complete all as specified and directed. |
| 16 | Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould glossy finish with double coating, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand all as specified and directed. By Engr-in-Charge. |
| 17 | S & F in repair road side safety traffic convex mirror of dia 32inches with radius of curvature 500-700mm of thickness 4-6mm ( acrylic) and optical specificats are 120-150 degrees, reflective coating of aluminium or silver with reflectyvity 85-95% with and including mounting on existing pipe including fixing with bracket, clamp and nut bolt etc complete all as specified and directed. |
| 18 | Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded or pointed in cement mortor complete all as directed. |
| 19 | Demolition of cement concrete of ground floor n exc 15 cm in depth in any position not otherwise specifically provided for complete all as specified and directed. |
| 20 | M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping /bed blocks incl. weathering rounded or chamfered angles and throating incl. necessary form work req. as in specified and directed. |
| 21 | S&F in repair at or near ground level factory made kerb stone (minimum ht 250mm) of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. as per the directions of Engineer-in-Charge |
| 22 | M&L for applying two coat of synthetic enamel paint over concrete/ plastered surfaces along with prepration of any surfaces of any description over 10cm width or girth with priming paints plaster coat complete all as specified and directed. Please Enable Macros to View BoQ information |