| 1 | DSR item No.1.10 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group-C |
| 3 | DSR item No. 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 4 | 25 mm |
| 5 | DSR 1.23 Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 6 | 5/6 A switch |
| 7 | 15/16 amps switch |
| 8 | 3 Pin 5/6 A. socket outlet |
| 9 | 6 Pin 15/16 A. socket outlet |
| 10 | DSR item No.1.24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 11 | 5/6 A switch |
| 12 | 15/16 A switch |
| 13 | 3 pin 5/6 A socket outlet |
| 14 | 6 pin 15/16 A socket outlet |
| 15 | DSR item No. 2.10 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 16 | Single pole |
| 17 | Double Pole |
| 18 | Triple Pole & Neutral |
| 19 | DSR 11.1 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 20 | 3½ X 50 sq. mm 32mm) |
| 21 | 3½ X 95 sq. mm 45mm) |
| 22 | DSR item No.11.4 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 23 | 3½ X 50 sq. mm |
| 24 | 3½ X 95 sq. mm |
| 25 | DSR item No.2.2 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 26 | 125 A,36KA,FPMCCB |
| 27 | 200 A,36KA,FPMCCB |
| 28 | DSR item No.8.9 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt).(Please refer DNIT for complete specification of item no.9) |
| 29 | 24- 26 Watt |
| 30 | DSR item No.8.16 LED Flood Light, powder coated pressure die cast aluminium (System lumen efficacy ≥120 and <135 lm/Watt). .(Please refer DNIT for complete specification of item no.10) |
| 31 | 100 Watt. |
| 32 | DSR item No.8.13 LED Street light fixture, powder coated pressure die cast aluminium body (System lumen efficacy ≥120 <135 lm/Watt) .(Please refer DNIT for complete specification of item no.11) |
| 33 | 50 Watt. |
| 34 | S/E of stainless steel enclosure for MCCB 3 Pole / 4 pole. The enclosure shall be erected on existing angle iron board with nut bolts/ screws etc. to complete the job to the entire satisfaction of Engineer In Charge. The MCCB enclosure should be of Lauritz Knudsen/ Siemens/ Schneider/ Legrand / ABB Hanger make only. |
| 35 | 100/125/160 Amp. |
| 36 | DSR item No.9.2 Brush Less Direct Current (BLDC) Fan without Remote |
| 37 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 38 | Supply & erection of Exhaust Fan (heavy duty motor with copper wound metallic body) following size complete with motor, metallic blades, double ball bearing with minimum power consumption, rigid frame with rubber mounting for silent operation, epoxy powder coating along with metallic louver to be installed in the existing opening including cost of making the hole to suit the size of above fan making good the damage, Carriage Charges connection, testing, commissioning etc. as required to complete the job to the entire satisfaction of Engineer-in-charge. |
| 39 | Size 15 inch (380mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP) / Orient (Industrial Heavy Duty)/ Usha (Turbo HDEF)/ Crompton (EXHD380-6-1)/ Bajaj (Supreme Plus) make only. |
| 40 | Size 18 inch (450mm) Sweep, 900 RPM Heavy Duty Exhaust fan (Single Phase) with louver of Havells (Turbo Force SP) / Orient (Industrial Heavy Duty)/ Usha (Turbo HDEF)/ Crompton (EXHD450-6-1)/ Bajaj (Supreme Plus) make only. |
| 41 | S/E of Bakelite holder ISI marked installed on exiting Jn. Box/ wooden block including connection etc as required. The holder should be of Anchor (Penta)/ Havells (Reo)/ SSK make only. |
| 42 | Supply & erection of sheet metal distribution board of suitable size of required number of ways for mounting Miniature Circuit Breaker/ Isolators including connection & bonding to the existing earth etc. as required to the entire satisfaction of Engineer-in-charge. |
| 43 | Sheet metal SP&N Distribution board (dust protected) provided with din bar suitable for incorporating MCB’s/Isolator 4 way. |
| 44 | Locating of fault of LT / HT cables laid in underground with the help of fault locating machine. It includes the cost of arrangement of power supply / generator required during the fault locating & digging the earth after found fault location & draw out the faulty cable from the ground and all petty materials required to complete the job to the entire satisfaction of Engineer-in-charge. |
| 45 | S/E of electronic fan regulator step type socket type in the existing bakelite sheet including cutting the sheet and making connection etc. The job includes all labour and petty material required to complete the job to the entire satisfaction of the Engineer-in-chaege of the work. The fan regulator should be of Anchor(Penta)/ Havells (Reo)/ SSK make only. |
| 46 | Supply & erection MCB 4 pole 63 Amp 415 Volt 10KA Breaking Capacity ‘C’ curve without enclosure. The job includes the labour charges and other petty material required to complete the job. Please Enable Macros to View BoQ information |