| 1 | Labour for cutting/pruning of tree branches along security light pole around 2 mtr radius of security light fitting and removing from site including arrangement of T&P (i.e Axe , rope & ladder etc ) complete all as specified and directed. |
| 2 | M&L for attending and rectifying any type of street light, flood lights, perimeter lights fittings, high mast lights, gate light, post top lantern, garden lights, switches/ sockets, bulb, holders, pole box, power point, DBs, MCBs service connection by decarbonising neutrals,checking for any loose connections in the boards all complaints by electrician and helper in 29 wing, DSC line, Veer Path, South Camp, Happy Home, Ashiyana Mess, SNCO's, JCO's Mess and office and other area as directed by Engr- in Charge. Note:-(i) Each job shall consist of a minimum of five complaints. (ii) Each job (comprising a minimum of five complaints) shall be executed by one electrician assisted by one helper. (iii) The Contractor shall be entirely responsible for ensuring safety and security in accordance with MES standards. The Contractor shall also be fully responsible for the safety of all personnel engaged on the work and shall provide all necessary safety equipment, appliances, and tools. (iv) The Department shall not be liable for any compensation on account of any accident, injury, or loss sustained by the Contractor’s workmen/employees during the execution of the works, and the Contractor shall be solely responsible for the same. (v) All tools and plants required for execution of the work, including but not limited to pliers, screwdrivers, testers, test lamps, clamp meters, ladders, etc., shall be arranged and provided by the Contractor at his own cost.(vi) All complaints shall be attended to promptly, round the clock, as and when directed by the Engineer-in-Charge. No complaint shall be refused or left unattended. (vii) The Contractor shall ensure that all defects are rectified and the lights are made functional within 4 (four) hours from the time of receipt of the list/intimation of defective lights. In the event of failure to restore any light within the stipulated time for any reason whatsoever, a recovery at the rate of Rs. 200/- (Rupees Two Hundred only) per defective light per day shall be effected from the Contractor’s dues under RAR/Final Bill. (viii) The Contractor shall provide, at his own cost, adequate transport including vehicles with fuel and a suitable mounted hydraulic ladder for execution of the work. (viii) The Contractor shall maintain a proper and up-to-date register of repair and maintenance, clearly indicating details of spares replaced for each light. The same shall be got authenticated daily by the concerned JE (E/M). The register shall be produced to the Engineer-in-Charge for inspection every Monday or as and when called for.(ix) The Contractor shall maintain at all times adequate stock of spares and materials required for repair and maintenance of street lighting systems in consultation with the concerned JE (E/M). All minor materials such as screws, insulating tapes, sub-main wires, gaskets, etc., and all necessary spare parts for fittings and accessories including switches, sockets, bulbs, holders, pole boxes, power points, DBs, MCBs, etc., required to keep the installation in efficient working condition shall be arranged and supplied by the Contractor. The cost of all such materials and spares shall be deemed to be included in the rates quoted by the Contractor under this item and no extra payment shall be admissible on this account. |
| 3 | Disconnecting & dismantling of damaged/ U/s cable any type /make and Supply & laying in repair/replacement of cable PVC Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs/ferrul both end of cable and testing complete all as directed for following size :-(a) 4 Sqmm 2 core[Note: Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately] |
| 4 | (b) 6 Sqmm 2 core |
| 5 | (c) 10 Sqmm 2 core |
| 6 | Disconnecting & dismentling of damaged/unsv cable any type /make and Supply & laying in repair/replacement of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs/ferrul both end of cable and testing complete all as directed for following size :-(a) 10 Sqmm 4 core[Note: Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid seperately] |
| 7 | (b) 16 Sqmm 4 core |
| 8 | (c) 25 Sqmm 3.5 core |
| 9 | (d) 35 Sqmm 3.5 core |
| 10 | (e) 50 Sqmm 3.5 core |
| 11 | Excavation in trenches not exc 1.50m wide and n.exc 1.50m in depth, getting out for electric cable complete in any type of soil complete all as specified and directed. Note : (i) Excavation shall be carried out manually. Use of mechanical equipment such as JCB or any other excavator shall not be permitted at site.(ii) The Contractor shall exercise due care to avoid damage to existing services such as cables, pipelines, PCC plinths, and other installations. Any damage caused during execution of the work shall be made good/repaired by the Contractor at his own cost to the complete satisfaction of the Engineer-in-Charge, and no extra payment shall be admissible on this account.(iii) Necessary precautions shall be taken for safe excavation as directed by the Engineer-in-Charge. |
| 12 | Removing surplus excavated soil to a distance n.exc 50m and depositing where directed at a level n. exc 1.5 mtr above starting point complete all as specified and directed. |
| 13 | Returning, filling in, soil obtained from excavation including spreading, levelling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed. |
| 14 | Supply and laying flyash bricks laid dry and flat across the length of cable for protection of cable complete all as specified and directed. |
| 15 | M&L for sand cushioning with Narmada Sand to underground cable (8 cm thick before laying and 15 cm thick after laying the cable complete all as specified and directed.Note: Punned thickness shall be measured |
| 16 | M&L for horizontal boring under roads/paths of 40/50 mm diameter using trenchless technology, for passing of cable, GI pipe in hard/soft/loose soil, at a minimum depth of 1.0 m below road/path level or as directed by the Engineer-in-Charge, complete all as specified and as directed. |
| 17 | S&F in replacement, GI tubing (light grade) with all necessary fittings, laid in trenches/under road crossings/fixed on poles, walls, or under floors/used as garden posts, including 02 Nos. mild steel flat iron clamps of size 35 × 3 mm for supporting the pipe to the pole, complete all as specified and as directed by the Engineer-in-Charge, of the following:-(a) 40 mm bore size |
| 18 | (b) 50 mm bore size |
| 19 | S&F in replacement of Pole box junction three phase of size 205x 250 x 120 mm, made of 2 mm MS sheet factory painted with synthetic enamel paint, and inbuilt locking arrangement, out door type , fix to pole with suitable MS clamp comprising of alluminium busbar 20 Amp 04 Nos fix on epoxy insulated support and one MCB 06-32 Amp 10 kA 240 volt complete all as specified and directed. |
| 20 | M&L for applying two coats of aluminium paint over a coat of red oxide on Steel tubular pole of following length including cross arms and clamps except embedded portion of pole in ground and concrete after removing old painted surfaces by scraping of poles complete and making colour band with synthetic enamel paint of approved colour up to 1.20 m from coping level including numbering of poles in 150 mm dia of approved colour paint complete all as specified and directed.(a) 11 m |
| 21 | (b) 09 m |
| 22 | M&L for painting of LT PCC poles 9.00 m with acrylic paint after apply two coat of cement base primer and making the surface smooth including painting of cross arms, clamps, etc with two coat of aluminium paint and providing alternative strip of 30 cm width (3 black and 2 yellow) from bottom of pole to 1.5 m height, writing of pole numbers in yellow circle 15 cm with black paint on poles complete all as specified and directed. |
| 23 | Dismantling and taking down street light fittings/ Post Top Lantern/ down lighter of any wattage/size for repair or replacement of burnt/worn out accessories or carrying to MES store complete all as directed by Engr-in-charge.Driver Make : Phillips/Bajaj/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 24 | M&L for repairing of unserviceable LED street light any make /model of 90-120 watt cap by replacing compact LED electronic driver suitable to operate on 120 to 270 Volt, 50/60 Hz AC supply, protection grade IP-66 with surge protection complete all as specified and directed. Driver Make : Phillips/Bajaj/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 25 | M&L for repairing of unserviceable LED street light any make /model of 60-72 watt cap by replacing compact LED electronic driver suitable to operate on 120 to 270 Volt, 50/60 Hz AC supply, protection grade IP-66 with surge protection complete all as specified and directed. Driver Make : Phillips/Bajaj/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 26 | M&L for repairing of unserviceable LED street light any make /model of 40-50 watt cap by replacing compact LED electronic driver suitable to operate on 120 to 270 Volt, 50/60 Hz AC supply, protection grade IP-66 with surge protection complete all as specified and directed. Driver Make : Phillips/Bajaj/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE.Note for item No 15.00 to 18.00:(i) The Contractor shall distinctly mark identification (i.e. CA No. or firm name) on each component replaced under repair of street lighting using a permanent paint marker. Any item found unmarked shall be deemed as not replaced and shall not be considered for payment. The Contractor shall also be liable to replace, at his own cost, any replaced item that becomes unserviceable for any reason during the execution of the Contract Agreement (CA) and up to the expiry of the Defect Liability Period.(ii) The Contractor shall report daily at 09:00 hrs at the office of AGE (E/M) on all working days for obtaining locations/details of unserviceable street/garden/post-top/search light fittings from the MES representative. Failure to report and/or to rectify the defects to restore the fittings to serviceable condition as stipulated shall attract a penalty of Rs. 200/- per complaint per day, which shall be recovered from the Contractor’s dues.(iii) Accessories/components required for replacement shall be measured and paid for separately under the relevant items of the Schedule. However, no payment shall be admissible for any item not duly recorded, verified, and authenticated by the concerned JE (E/M). |
| 27 | M& L for repairing of unserviceable Garden/Gate light of any type/make by replacing burn out/worn-out/ weak Normal LED lamp 05/07 watt and re- fixing the fitting in position after repair and testing complete. Make : Phillips/Bajaj/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 28 | M& L for repairing of unserviceable Garden/Gate light of any type/make by replacing burn out/worn-out/ weak Normal LED lamp 9/11 watt and re- fixing the fitting in position after repair and testing complete. Make : Phillips/Bajaj/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 29 | M& L for repairing of unserviceable Gate light of any type/make by replacing burn out/worn-out/ weak LED lamp 25 watt and re- fixing the fitting in position after repair and testing complete. Make : Phillips/Bajaj/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 30 | S&F rigid PVC conduit 'medium grade' of size 15 mm bore incl fittings, ISI marked, fixing with PCC pole/ steel tubular pole for wiring connection from pole box to light fitting and supporting with 03 Nos GI strip clamp , nut bolt and complete all as specified and directed. |
| 31 | S&F in replacement of PVC insulated PVC sheathed stranded copper conductor cable 2.5 Sqmm twin core complete all as specified and directed. |
| 32 | M&L for replacement of Lamp holder of post top lantern fitting/decorative fitting/PTL complete all as directed by engr-in-Charge. |
| 33 | Supply & fixing PVC insulation tape of width - 18 mm, thickness - 0.125 mm in length of 25 mtr, ISI marked for proper insulation of joints in wire where as required or directed |
| 34 | S&F in replacement of interal LED Aviation light comprising of aluminium housing with polycorbonate enclosure including provision of three core copper cable conductor of size 2.5 Sqmm 3 core of white covering for making connection, fixing the fitting on wall including all necessary fixing accessories complete all as directed and specified by Engr- in-Charge.Make: Phillips/Bajaj/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 35 | Taking down (from High Mast) of single phase electric operated search light motor of capacity 2 HP , dismantling & Rewinding with existing gauge size copper wire and as existing Nos of turns of coils for maintaining existing capacity of the motor and varnishing ,drying incl re fixing & testing for proper rotation of search light fitting at watch tower complete all as specified and directed. |
| 36 | S&F LED street light fitting of 90 Watt high pressure die cast aluminium housing, with minimum 125 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and S&F PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3core from junction pole box to fitting complete all as specified and directed. Make : Phillips/Bajaj/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 37 | S&F LED streetlight fitting of 70 Watt high pressure die cast aluminium housing, with minimum 120 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and S&F PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3core from junction pole box to fitting complete all as specified and directed.Make : Phillips/Bajaj/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 38 | S&F LED Flood light fitting of 100 Watt high pressure die cast aluminium housing, with minimum 110 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and S&F PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3core from junction pole box to fitting complete all as specified and directed. Make : Phillips/Bajaj/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 39 | S&F LED Flood light fitting of 200 Watt high pressure die cast aluminium housing, with minimum 110 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and S&F PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3core from junction pole box to fitting complete all as specified and directed. Make : Phillips/Bajaj/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 40 | S&F LED Flood light fitting of 250 Watt high pressure die cast aluminium housing, with minimum 120 lumen/watt system efficacy, covered potted designed driver of same make as fitting, heat resistant toughened glass with silicon gasket for IP-66 protection, better optics for uniform distribution roadway luminaires complete and fixing on existing bracket of steel tubular pole and connecting the fitting electrically using 3 way 10 amp connector and S&F PVC conduit 20 mm & PVC copper cable 2.5 sqmm 3core from junction pole box to fitting complete all as specified and directed. Make : Phillips/Bajaj/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 41 | S&F new generation,post top, energy saving,environment friendly, long life aesthetically designed with good indirect symmetrical light distribution, die-cast aluminium bottom housing and spun aluminium top reflector with decorative clear acrylic diffuser IP65 protection luminaire with high power LEDs as light source of 45 watt, colour temp 5700K as light source including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm complete all as specified & directed. Make : Bajaj, Cat Part No. BGCTN 45W LED WH / Phillips/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 42 | S&F new generation,post top, energy saving,environment friendly, long life aesthetically designed with good indirect symmetrical light distribution, die-cast aluminium bottom housing and spun aluminium powder coated housing with higher eiciency lighting IP65 protection luminaire with high power LEDs as light source of 40 watt, colour temp 5700K as light source including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm complete all as specified & directed Make : Bajaj, Cat Part No. BGCTNP 40W LED WH / Phillips/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 43 | S&F new generation,post top, energy saving,environment friendly, long life aesthetically designed with good symmetrical light distribution, spherical shape polycarbonate opal and clear diffuser with high power LEDs as light source of 25 Watt, color Temp- 4000K & IP65 protection including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm complete all as specified & directed.Make : Bajaj Cat Part No. BLPTSP 25W NW LED / Phillips/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 44 | S&F new generation, LED Bollard in cylinderical shape, energy saving, environment friendly, long life aesthetically designed aluminium landscape luminaire for diffused lighting with high power LEDs as light source & IP65 protection including connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm complete all as specified & directed.Make : Bajaj Cat Part No.BGBOL 605 9W LED WH (1.0 M) / Phillips/Crompton/Orient/Havells/Wipro/ Make as specified in Particular Specifications (List of Make) as approved by GE. |
| 45 | Cutting and clearing of grass and roots touching or falling on electric poles up to the top of pole, including cleaning of site, complete all as specified and as directed by the Engineer-in-Charge.Note:The work shall be carried out only at locations/spans where grass and roots are existing around the electric poles. |
| 46 | S&F in replacement of Pole box three phase of size 205x 250 x 120 mm made out of 2 mm MS sheet factory made with inbuilt locking arrangement, out door type , fix to pole with suitable MS clamp comprising of alluminium busbar 16 Amp 04 Nos fixe on epoxy insulated pole and MCB 6 Amp 10 kA 240 volt complete all as specified and directed. |
| 47 | S&F in replacement of bracket for street light made out of 40 mm bore GI pipe medium grade not less than 1.2 mtr length bent at 120 degree to shape fixed on pole/wall with and including 50x6mm FI clamps (02 Nos) with nut bolts, washers including painting of clamps with two coats of synthetic enamel paint over a coat of red oxide primer complete. |
| 48 | S&F in replacement of MS bracket for mounting flood light fitting made out of MS angle iron of size 40x40x6 mm of length not less than 1.0 mtr, fixed to pole/ earth and grout using PCC & clamp, nut & bolts including painting of bracket with one coat of synthetic enamel paint over a coat of red oxide primer complete. Please Enable Macros to View BoQ information |
| 49 | S&F in replacement of MS bracket for mounting flood light fitting made out of MS angle iron of size 40x40x6 mm of length not less than 1.0 mtr, fixed to pole/ earth and grout using PCC & clamp, nut & bolts including painting of bracket with one coat of synthetic enamel paint over a coat of red oxide primer complete. Please Enable Macros to View BoQ information |