| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2X 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/ Anchor/Apar/ Grandlay/ equivalent as directed by engineer incharge.) single core cable in surface / recessed medium class PVC conduit,( excluding the cost of conduit) with modular switch ( Legrand Mylinc/ Legrand Alzy /SSK NV/schneider Zencelo /Crabtree athena / eq. make to be approved by EIC.), modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 2 | Wiring for group controlled ( Looped) light point/ fan point/ exhaust fan point/ call bell point ( without independent switch etc) with 2X 1.5 sq.mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/ Anchor/ Apar/ Grandlay/ eq. make to be approved by EIC ) single core cable in surface / recessed medium class PVC conduit,( excluding the cost of conduit) and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 3 | Wiring for light/ power plug with 2X4 sq. mm + 1X 4 sq. mm earth wire , FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/Apar/ Grandlay/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit ( excluding the cost of conduit) |
| 4 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch,modular plate, suitable GI box , connections etc. as required. Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena / eq. make to be approved by EIC.) |
| 5 | Wiring for lighting circuits/ inverter circuits/ 6- 10 amp power plug with 2X2.5 sq. mm FRLS PVC insulated copper conductor ( Havell/Polycab/ Fenolex/Anchor/ /Apar/ Grandlay/ equivalent as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit,( excluding the cost of conduit) alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 6 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 nos. 3 pin 5-10 A modular socket outlet and 2 nos. 5-10 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). Modular Switch & Socket:- ( Anchor roma plus/Legrand Mylinc /SSK NV/schneider Zencelo /Crabtree athena/ eq. make to be approved ny EIC) |
| 7 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 8 | Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP M.C.B, \\"C\\" curve including connections, painting etc. as required. |
| 9 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor (Havell/Polycab/ Fenolex/ Anchor make.), single core cable in surface/ recessed medium class PVC conduit as required.( excluding the cost of conduit) |
| 10 | (a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 11 | ( b ) 2 X6 sq. mm + 1 X 6 sq. mm earth wire |
| 12 | ( c )4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 13 | (d) 4 X 16 sq. mm + 2 X 6 sq. mm earth wire |
| 14 | Supplying and fixing of following sizes of medium class PVC conduit( Anchor/ Ravindra/ Eq. make)along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required, with cement plaster,wall putty, paint complete. |
| 15 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) including bends, Tees, cross members and allied accessories with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. |
| 16 | 200 mm width X 50 mm depth X 1.6 mm thickness |
| 17 | Supply installation testing and commissioning of 18 W + LED Surface/recess, square or round Mounted light luminary fitting shape with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Housing and Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. The job includes AMC (reckoned from date of successful commissioning) of lighting fixtures for a period of Two years ,which includes replacement of fixtures of Philips/ Helonix/Wipro/ eq. make. sample to be approved before installation.. |
| 18 | S/F testing and comm. Of surface mounted LED Batten 20 watt-22 watt +- 1watt commercial series (cool/warm) 4 ft. with minimum system lumen efficacy of 100 lm/W with Pressure Die cast Aluminium Heat Sink and P.F.>0.95 ,THD<10% ,CCT 5700K, CRI 80.The LED with Useful life of 50000 Hrs at L70, seperate driver, heat sink, earthing provision.. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 2kV. Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India. Philips/ Helonix /Wipro/ eq. make. sample to be approved before installation. |
| 19 | S/F testing and comm. Of MCB's 10 kA of the below mentioned capacities in sub main controls legrand C curve/ Schinider/ L&T ./ABB/equivalent make as directed by engineer incharge. |
| 20 | a) 6-32 Amp SP MCB |
| 21 | b) 40-63amp DP MCB |
| 22 | c) 40-63amp TPN MCB |
| 23 | Supply installation testing and comm. Of 200-250mm sweep exhaust fan Shutter type of havell /Bajaj/Crompton/equivalent make as directed by engineer incharge, including making of space in wall/ window as per site requirement and necessary connections. |
| 24 | Supply and fixing modular blanking plates on existing modular switch plates, excluding cost of plates. |
| 25 | Supply, Installation, Testing and Commissioning of decorative 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete . USHA Striker galaxy/Havells Oyster matalic/CromptonAura/equivalent make as directed by engineer incharge. |
| 26 | Supply and fixing of 6 amp/250 V A.C fan dimmer step type 2 module with cover plate Anchor Roma plus/SSK NV/ equivalent make as directed by engineer incharge. |
| 27 | Supplying and fixing following way, Triple pole and neutral, sheet steel, MCB distribution board,( legrand/ Shinider/Hager/ABB / eq. make to be approved by EIC) 240 V, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator) |
| 28 | 8 way (4 + 24), Double door |
| 29 | 6 way (4 + 18), Double door |
| 30 | Supply fixing testing and comm. Of backlite holder /batten holder/angle holder/ceiling rose SSK/Anchor / eq. make to be approved by EIC incl. PVC Block. |
| 31 | Providing of Chemical earthing as per IS standards by way of digging 10' deep pit then embedding 3 meter G.I Earthing electrode , 80mm dia. connecting the plate with main control board by 10 SWG copper wire with 1/2\\" dia. Full thread brass nut and bolt and washers. Refilling of pit with chemical compound. |
| 32 | Supply, laying ( partly underground/partly overhead) , testing and commissioning of PVC alluminium armoured cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and aluminium lugs of required size. |
| 33 | b)120 sq.mm 3.5 core ( armoured) . |
| 34 | d)70 sq.mm 3.5 core ( armoured) |
| 35 | Supply installation testing and comm. of flood light 100 W ( warm, white ), Epoxy powder coated die-cast aluminium housing (LM24) with elegantly designed heat sink for efficient thermal management, sturdiness & excellent corrosion resistant. PG9 gland is used for cable entry and provision for loopin-loopout class 1, IP66, IK 07, , with high power LED's as light source with Built-In Potted IP67 electronic LED driver with APFC,lower THD, toughned glass and secondary lens,Open Circuit Protection, Over Voltage Protection, Surge Voltage Protection upto 10kV With Built In SPD & other safety test as per IS 15885 Part-2/Sec 13, IEC60598-1. Preferred make: Philips/ Havell /Wipro/Crompton / eq. make to be approved by EIC. The job also includes the angle iron stand of suitable size to be grouted in cement concrete with hold fasteners complete job. |
| 36 | Design, Fabrication, Supplying, Installation, Testing and Commissioning of following panel, duly manufactured from CPRI approved manufacturer, made out of 2mm thick M.S. sheet steel , floor/wall mounted, vermin and dust proof, indoor type with suitable size of angle iron legs for grouting in the ground, with lockable type hinged doors, duly painted with provision for fixing of following switch gears, , Aluminium Bus Bar of various ratings after taking Derating factor into account, and other allied accessories etc. as required.( As per approved design,size may vary as per site requirement) |
| 37 | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. |
| 38 | Normal INCOMING: |
| 39 | a)250A 4P MCCB 50 KA including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB / eq. make to be approved by EIC. |
| 40 | b) 4 No. of Aluminium Bus Bar of 400 Amp. |
| 41 | c)Digital meters and phase indicators -1 set. |
| 42 | d) onload Change over switch 160 Amp for generator.Front operated. |
| 43 | e) 4 No. of Aluminium Bus Bar of 300 Amp. |
| 44 | Inverter Incommer |
| 45 | (a) 100 amp DP MCCB 16 K including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB/ eq. make to be approved by EIC |
| 46 | (b) 200 Amp 2 strip bus bar |
| 47 | c)Digital meters and phase indicators -1 set. |
| 48 | OUTGOING: |
| 49 | a)40-63 amp TPN MCB 16 K Legrand/ Shinider/ABB / eq. make. sample to be approved before installation.. |
| 50 | c) 40-63amp DP MCB |
| 51 | c) space for 24 way MCB's |
| 52 | Supply, Installation, Testing & Commissioning of 10 KVA 3-Phase IN single-Phase out ON Line UPS System with provision for connecting in 3 phase input and 3 phase output configuration, unity pf, LCD display with gravity sensor, built in OVCD, to provide backup time of 60 minutes at full load (minimum VAH 24000), With In-Built Isolation Transformer of reputed make dully ISI Marked (APC Schineider/ETON/VERTIV/ equivalent standard make ) (Compitable to Genrator Supply having varing frequency) With on line double conversion topology, high frequency techonology, with front LCD,automatic bypass for fault tolerance & complete with required Number, 12 Volts 65 AH SMF VRLA Batteries ( Exide/ Amaron/Quanta / eq. make to be approved by EIC) with connecting links with angle iron battery stand complete job, complete with battery rack with two year warranty against any manufacturing defect. The job further includes AMC for UPS and batteries for a period of three years with replacement warrenty reckoned from date of sucessfull commissioning. |
| 53 | Supply, installation, mechanical erection, testing and commissioning of three phase 20 KVA diesel generator set KIRLOSKAR/Cummins/Mahindra /ASHOKA LEYLAND (CSH) / eq. make to be approved by EIC , IP 23, H-Class, turbo charged developing required BHP 1500 RPM under NTP with 10 % overloading factor, with microprocessor based digital display genset engine controller for monitoring, metering, protection, control system,residential exhaust Siliencer, with batteries,including required capacity of AMF Panel inbuilt including first fuel fill etc. conforming to latest Govt. Emission norms CPCB-4, ( Complete job). with CMC for a period of two years |
| 54 | Carrying out foundation of PCC type, cement concrete to be carried in 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)in foundation of DG set etc including form work etc as required the job also includes supply and carriage etc of the requsite material upto the site. as per approved drawings |
| 55 | S/I testing and comm. Of three phase 30 KVA 50HZ oil cooled(Transformer oil is to be provided with stabilizer conforming to IS 335,IEC296)) unbalanced type servo voltage stabilizer (A.E / Cosco/Chinar/ Electricfield / eq. make to be approved by EIC) having an input voltage ranging from 156V to 415 V ( phase to phase) and balanced output voltage of 415V, +/- 1%. ( Test certificate to be provided by the manufacturer) The unit incorporate |
| 56 | a) 0-500V moving iron type voltmeter with selector switch. |
| 57 | b) A three phase change over switch to read voltage on incoming and output side |
| 58 | c) indicating lights 6 No two numbers for each of the motorised units, one for lower limit and other for higher limit. |
| 59 | d) six push button control for movement operation of three motorised dimmer units two for each unit i.e one for raise operation and one for lower operation under the conditions of adjustment of auto/mannual selector switch (DPDT) |
| 60 | e) Single phase Preventer ( contactor Switch of required rating) Legrand make. |
| 61 | f) six potential meter resistance with lock meter two for each phase control, one for sensitivity and other for level control. |
| 62 | g) two sets of indication lamps three numbers each to indicate output and input indication |
| 63 | h) 20 % over load bearing capacity for one hour. |
| 64 | Supply installation testing and commissioning of energy efficient 2 Ton inverter type split Air Conditioning system( Hot and cold) suitable for operation on AC supply single phase 220 V . The indoor unit fitted on wall by employing suitable clamps and the outdoor unit fitted on the wall by using suitable angle iron stand fitted with nuts/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ pvc insulated coper cable and a battery operated wireless remote unit. the job also includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning.( Mitsubishi/Toshiba/O-General/Hitachi/ equivalent standard make as desired by Engineer Incharge) |
| 65 | Supply installation testing and commissioning of energy efficient 1.5 Ton inverter type split Air Conditioning system suitable for operation on AC supply single phase 220 V . The indoor unit fitted on wall by employing suitable clamps and the outdoor unit fitted on the wall by using suitable angle iron stand fitted with nuts/bolts outside the room to avoid noise, including standard length of suitable size copper tubing covered with nitrilic foam, topping up with refrigerant for additional length of piping if required, PVC flexible drain pipe, suitable capacity 3 core sheathed/ pvc insulated coper cable and a battery operated wireless remote unit. the job also includes repairs to walls wherever the same are cut and the AMC of AC for a period of one and a half year from date of successful commissioning.( Mitsubishi/ Toshiba/ O-General/ equivalent standard make as desired by Engineer Incharge) (Hot and Cold type) |
| 66 | Supply, Installation, testing and commissioning of relay type voltage stabilizer suitable for 1.5 Ton - 2 Ton AC operating from input voltage 90-260 Volts thereby producing output voltage of 230 volts +/- 3 % ( Vguard/ Livgaurd/LG / eq. make to be approved by EIC) Please Enable Macros to View BoQ information |