| 1 | Mumbai Directorate (Supply, Installation, Integration, Testing and Commissioning of all items including Three Years Warranty and Seven years CAMC as applicable) |
| 2 | Remote Terminal Units consisting of instrumentation, sensors/transducer, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc. at Type 1 stations : 09 ( i) Hazira ,ii) Wasi Borsi,iii) Tarapur, iv) Uttan, v) Nanvel Point, vi)Tolkeshwar Point, vii) Jaigad, viii) Ratnagiri ,ix) Rajapur) |
| 3 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc . at Type 2 stations : 08 ( i) Luhara Point, ii) Kanai Creek, iii) Valsad Khadi, iv) Umergam, v) Satpati, vi) Arnala,vii) Korlai Fort, viii) Kelshi) |
| 4 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc . – Type 4A stations : 04 ((i) Prongs Reef Island (ii) Dahanu (iii) Murudu Janjira (iv) Harnai ) |
| 5 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc . at Type 4B stations : 02 ( i) Kanhoji Angre Island.,ii) Chaul Kadu Island) |
| 6 | Work Stations with 27” LED Monitor, printer ( All in One multifunction machine A4 size ) and associated software at all RCS (02 work stations each at 04 RCS ) specifications as per section 6.9 |
| 7 | Work Stations with 27” LED Monitor, printer ( All in One multifunction machine A4 size ) and associated software (02 work stations at MCS) specifications as per section 6.9 |
| 8 | Data base server (Comprises with Webservice facility) with necessary Router/hardware/software including Firewall etc (02 redundant server Main/Standby at MCS Mumbai Directorate) The Firewall/router shall have at least two spare ports for future use. specifications as per section 6.9 |
| 9 | Suitable mounting server rack for mounting data base server at MCS.(01 rack at MCS ) |
| 10 | 8 Port KVM Switch 01 at MCS |
| 11 | 55” LED Monitor at MCS, specifications as per section 6.9 |
| 12 | 16 Port Ethernet network layer Switch (01 switch at 01 MCS & 04 RCS ) |
| 13 | Supply and Installation of necessary hardware/software for GSM SIM/FTTH Communication terminals/system including antenna systems & associate data integration devices (modem, power supplies etc) and Airtime/Bandwidth/internet Charges during 03 years warranty period . (22 sites under (17 RS + 01 MCS+ 4 (RS+RCS)) |
| 14 | Dual Duplex Microwave Communication Devices (License Free) including antenna systems & associate data integration devices (modem, power supplies etc) for Type 4B Stations |
| 15 | Supply and Installation of VoIP phones including adaptors, modems, cables and other required accessories ,configuration etc |
| 16 | Solar Power System for Independent Operation of the Remote Control and Monitoring System at Remote Terminal Unit with autonomy of 03 day at Type 4A & 4B locations including Solar Panels, VRLA batteries, Charge Controller, Cables, wiring, Mounting Stands (all metal fabrication shall be galvanized), Junction Boxes, etc. (06 stations) |
| 17 | 03 KVA online UPS with battery for 60 mins backup at full load at RCS (01 each at 04 RCS ) |
| 18 | 06 KVA online UPS with battery for 60 mins backup at full load ( 01 at each MCS) |
| 19 | Protection devices at each site, specifications as per Section 6.6i) Isolation Transformersii) Surge protection for each phase (17 Type 1 & 2 Llighthouses, 04 RCS and 01 MCS) |
| 20 | Lightning Arrester complete system with proper Earthing (specfification as per sec 6.6 ) facility for each site for all outdoor installations Type 4A & 4B Lighthouses |
| 21 | Earthing with standard copper strip, copper plate and wire as per the specification, at each site separately (for Remote Monitoring Equipment and solar power plant for RCMS Equipment), specifications as per section 6.6 28 sites under (23 RS+01 MCS+04 (RCS+RS)) |
| 22 | System technical manual, operation and maintenance/service manuals 05 set {01 for MCS 04 for RCS and 01 for HQs, Noida Library} |
| 23 | Standard make Computer Table (02 tables each at 01 MCS & 04 RCS ) |
| 24 | Standard make Revolving chair {02 chairs each at 01 MCS & 04 RCS } |
| 25 | Standard make 1.5 Ton Split invertor AC 5 star rating {latest Model 2023/2024} with copper condenser 02 A/Cs at each site. (01 MCS & 04 RCS) |
| 26 | Training as per para 6.15 |
| 27 | Safe removal and dismantling of existing system at all the sites |
| 28 | Buy Back of all the removed items from all the sites |
| 29 | Additional items 1 in (The description/ requirement of the product will be discussed in the pre-bid meeting and accordingly bidders may quote their price) |
| 30 | Additional items 2 in (The description/ requirement of the product will be discussed in the pre-bid meeting and accordingly bidders may quote their price) |
| 31 | Standard make Laptop (i7 processor with 32 GB RAM or Higher, Pre loaded Windows 11 Pro or latest, 1 TB SSD, minimum 04 USB port, ethernet port) loaded with all applicable softwares for programming of PLC, Antivirus etc as required (01 at MCS Mumbai) |
| 32 | 5kg capacity CO2 type fire extinguisher with fixture 01 No each for RCS and MCS |
| 33 | Comprehensive annual maintenance contract (CAMC) for 23 RS, 04RCS and 01 MCS for Seven years including all spares (hardware/software) and equipments of VSAT/GSM/FTTH/Microwave/Lease Line(as applicable) |
| 34 | Airtime/Bandwidth/internet Charges during Seven years Comprehensive annual maintenance contract (CAMC) period of VSAT/GSM/FTTH/Microwave/Lease Line(as applicable) for 23 RS,04RCS and 01 MCS. |
| 35 | Goa Directorate (Supply, Installation, Integration, Testing and Commissioning of all items including Three Years Warranty and Seven years CAMC as applicable) |
| 36 | Remote Terminal Units consisting of instrumentation, sensors/transducer, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc. at Type 1 stations : 06 ( i) Devgad, ii) Vengurla Point, iii) Aguada, iv) Bhatkal, v) Kaup, vi) Surathkal ) |
| 37 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc. at Type 2 stations : 04 ( i) Betul, ii) Tadri, iii) Honnavar, iv) Kundapur ) |
| 38 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, , power supplies, software, cabling, wiring etc . – Type 4A stations : 03 ( i) Achara, ii) Belekeri Island, iii) Malpe Island |
| 39 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc . at Type 4B stations : 03 ( i) Vengurla Rock Island, ii) Oyster Rock Island, iii) Sao George Island) |
| 40 | Work Stations with 27” LED Monitor, printer ( All in One multifunction machine A4 size ) and associated software at all RCS (02 work stations each at 02 RCS ) specifications as per section 6.9 |
| 41 | Work Stations with 27” LED Monitor, printer ( All in One multifunction machine A4 size ) and associated software (02 work stations at MCS) specifications as per section 6.9 |
| 42 | Data base server (Comprises with Webservice facility) with necessary Router/hardware/software including Firewall etc (02 redundant server Main/Standby at MCS) The Firewall/router shall have at least two spare ports for future use. specifications as per section 6.9 |
| 43 | Suitable mounting server rack for mounting data base server at MCS.(01 rack at MCS ) |
| 44 | 8 Port KVM Switch 01 at MCS |
| 45 | 55” LED Monitor at at MCS specifications as per section 6.9 |
| 46 | 16 Port Ethernet network layer Switch (01 switch at 01 MCS & 02 RCS) |
| 47 | Supply and Installation of necessary hardware/software including GSM SIM/FTTH Communication terminals/system including antenna systems & associate data integration devices, (modem, power supplies etc) and Airtime/Bandwidth/internet Charges during 03 years warranty period (15 sites (11 RS+ 01 MCS+ 02 (RS+RCS) +01 RT station Karwar) |
| 48 | Dual Duplex Microwave Communication Devices including antenna systems & associate data integration devices (modem, power supplies etc) for Type 4B Stations |
| 49 | Supply and Installation of VoIP phones including adaptors, cables and other required accessories ,configuration etc |
| 50 | Solar Power System for Independent Operation of the Remote Control and Monitoring System at Remote Terminal Unit with autonomy of 03 day at Type 4A & 4B locations including Solar Panels, VRLA batteries, Charge Controller, Cables, wiring, Mounting Stands (all metal fabrication shall be galvanized), Junction Boxes, etc. (06 stations) |
| 51 | 03 KVA online UPS with battery for 60 mins backup at full load at RCS (01 each at 02 RCS) |
| 52 | 06 KVA online UPS with battery for 60 mins backup at full load ( 01 at each MCS) |
| 53 | Protection devices at each site, specifications as per Section 6.6)i) Isolation Transformersii) Surge protection for each phase 14 sites (10 Type 1 & 2 Lighthouses, 02 RCS ,01 MCS and 01 RT station Karwar under Goa Directorate) |
| 54 | Lightning Arrester complete system with proper Earthing (specfification as per sec 6.6 ) facility for each site for all outdoor installations Type 4A & 4B Lighthouses |
| 55 | Earthing with standard copper strip, copper plate and wire as per the specification, at each site separately, (for Remote Monitoring Equipment and solar power plant for RCMS Equipment) specifications as per section 6.6 20 sites (16 RS+01 MCS+02 (RS+RCS)+01 RT Station Karwar) |
| 56 | System technical manual, operation and maintenance/service manuals 04 set {01 for MCS 02 for RCS and 01 for HQs, Noida Library} |
| 57 | Standard make Computer Table (02 tables each at 01 MCS & 02 RCS) |
| 58 | Standard make Revolving chair (02 chairs each at 01 MCS & 02 RCS) |
| 59 | Standard make 1.5 Ton Split invertor AC 5 star rating {latest Model 2023/2024} with copper condenser 02 A/Cs at each site. (01 MCS & 02 RCS) |
| 60 | Training as per para 6.15 |
| 61 | Safe removal and dismantling of existing system at all the sites |
| 62 | Buy Back of all the removed items from all the sites |
| 63 | Additional items 1 (The description/ requirement of the product will be discussed in the pre-bid meeting and accordingly bidders may quote their price) |
| 64 | Additional items 2 in (The description/ requirement of the product will be discussed in the pre-bid meeting and accordingly bidders may quote their price) |
| 65 | Standard make Laptop (i7 processor with 32 GB RAM or more, Pre loaded Windows 11 Pro or latest, 1 TB SSD, minimum 04 USB port, ethernet port) loaded with all software for programming of PLC (01 at MCS) |
| 66 | 5kg capacity CO2 type fire extinguisher with fixture 01 No each for RCS and MCS |
| 67 | Comprehensive annual maintenance contract (CAMC) for 16 RS, 02 RCS,01 MCS & 01 RT station for Seven years including all spares (hardware/software) and equipments of VSAT/GSM/FTTH/Microwave/Lease Line (as applicable |
| 68 | Airtime/Bandwidth/internet Charges during Seven years Comprehensive Annual Maintenance Contract (CAMC) period VSAT/GSM/FTTH/Microwave/Lease Line (as applicable) |
| 69 | Cochin Directorate (Supply, Installation, Integration, Testing and Commissioning of all items including Three Years Warranty and Seven years CAMC as applicable) |
| 70 | Remote Terminal Units consisting of instrumentation, sensors/transducer, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc. at Type 1 stations : 16 ( i) Mount Dilli, ii) Kannur, iii) Kadalur Point, iv) Beypore, v) Ponnani, vi) Chetwai, vii) Azhicode, viii) Vypin, ix) Manakkodam, x) Alappuzha, xi) Thangassery, xii) Vizhinjam, xiii) Kavaratti, xiv) Kiltan (S), xv) Kalpeni, xvi) Minicoy(S)) |
| 71 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, power supplies, software,cabling, wiring etc . at Type 2 stations : 04 ( i) Kasargod, ii) Valiyazhikkal, iii) Anjengo, iv) Androth (E)) |
| 72 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, cabling, wiring, power supplies, software, cabling, wiring etc . – Type 3 stations : 10 ( i) Mahe, , ii) Kovilthottam, iii) Kiltan (N), iv) MInicoy (N), v) Androth (W), vi) Agatti, vii) Bitra, viii) Chetlat, ix) Kadamat, x) Amini) |
| 73 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, power supplies, software cabling, wiring etc . at Type 4 A stations : 01 ( i) Thottapally |
| 74 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, power supplies, software cabling, wiring etc . at Type 4C stations : 03 ( i) Valiyakkkara, ii) Suhelipar, iii) Thinnakkara ) |
| 75 | Work Stations with 27” LED Monitor, printer (All in One multifunction machine A4 size ) and associated software at all RCS (02 work stations each at 06 RCS under ) specifications as per section 6.9 |
| 76 | Work Stations with 27” LED Monitor, printer ( All in One multifunction machine A4 size ) and associated software (02 work stations at MCS under ) specifications as per section 6.9 |
| 77 | Data base server (Comprises with Webservice facility) with necessary Router/hardware/software including Firewall etc (02 redundant server Main/Standby at MCS ) The Firewall/router shall have at least two spare ports for future use. specifications as per section 6.9 |
| 78 | Suitable mounting server rack for mounting data base server at MCS.(01 rack at MCS ) |
| 79 | 8 Port KVM Switch 01 at MCS |
| 80 | 55” LED Monitor at MCS specifications as per section 6.9 |
| 81 | 16 Port Ethernet network layer Switch (01 switch at 01 MCS & 06 RCS ) |
| 82 | Supply and Installation of necessary hardware/software including GSM SIM/FTTH Communication terminals/system including antenna systems & associate data integration devices (modem, power supplies etc) and Airtime/Bandwidth/internet Charges during 03 years warranty period (32 sites (25 RS+01 MCS+ 06 (RS+RCS)) |
| 83 | VSAT Communication Devices including VSAT Airtime Charges, other charges etc. till the end of warranty period for Type 4C Stations |
| 84 | Supply and Installation of VoIP phones including adaptors, cables and other required accessories, configuration etc |
| 85 | Solar Power System for Independent Operation of the Remote Control and Monitoring System at Remote Terminal Unit with 03 days of autonomy at Type 4A & 4C locations including Solar Panels, VRLA batteries, Charge Controller, Cables, wiring, Mounting Stands (all metal fabrication shall be galvanized), Junction Boxes, etc. (04 stations ) |
| 86 | 03 KVA online UPS with battery for 60 mins backup at full load at RCS (01 each at 06 RCS under ) |
| 87 | 06 KVA online UPS with battery for 60 mins backup at full load ( 01 at each MCS ) |
| 88 | Protection devices at each site , specifications as per Section 6.6)i) Isolation Transformersii) Surge protection for each phase at each site(31 Type 1, 2 & 3 Llighthouses, 06 RCS and 01 MCS under ) |
| 89 | Lightning Arrester complete system with proper Earthing (specfification as per sec 6.6 ) facility for each site for all outdoor installations Type 4A & 4C Lighthouses |
| 90 | Earthing with standard copper strip, copper plate and wire as per the specification, at each site separately, specifications as per section 6.6 i) Remote Monitoring and Control equipment at LHs, RCS, MCS ii) Communication equipment at LHs, RCS, MCS iii) Solar power plant at LHs41 sites (34 RS+01 MCS+06 RCS) |
| 91 | System technical manual, operation and maintenance/service manuals 08 set {01 for MCS 06 for RCS and 01 for HQs, Noida Library} |
| 92 | Standard make Computer Table (02 tables each at 01 MCS & 06 RCS ) |
| 93 | Standard make Revolving chair {02 chairs each at 01 MCS & 06 RCS } |
| 94 | Standard make 1.5 Ton Split invertor AC 5 star rating {latest Model 2024} with copper condenser 02 A/Cs at each site. (01 MCS & 06 RCS ) |
| 95 | Training prior to handing over the system and during 2nd year and 3rd year of warranty period for as per para 6.15 |
| 96 | Safe removal and dismantling of existing system at all the sites |
| 97 | Buy Back of all the removed items from all the sites |
| 98 | Additional items 1 (The description/ requirement of the product will be discussed in the pre-bid meeting and accordingly bidders may quote their price) |
| 99 | Additional items 2 (The description/ requirement of the product will be discussed in the pre-bid meeting and accordingly bidders may quote their price) |
| 100 | Standard make Laptop (i7 processor with 32 GB RAM or more, Pre loaded Windows 11 Pro or latest, 1 TB SSD, minimum 04 USB port, ethernet port) loaded with all software for programming of PLC (01 at MCS Cochin) |
| 101 | 5kg capacity CO2 type fire extinguisher with fixture 01 No each for RCS and MCS |
| 102 | Comprehensive annual maintenance contract (CAMC) for 34 RS, 06RCS and 01 MCS for Seven years including all spares (hardware/software) and equipments of VSAT/GSM/FTTH/Microwave/Lease Line(as applicable) |
| 103 | Airtime/Bandwidth/internet Charges during Seven years Comprehensive annual maintenance contract (CAMC) period of VSAT/GSM/FTTH/Microwave/Lease Line(as applicable) for 34 RS,06RCS and 01 MCS. |
| 104 | Chennai Directorate (Supply, Installation, Integration, Testing and Commissioning of all items including Three Years Warranty and Seven years CAMC as applicable) |
| 105 | Remote Terminal Units consisting of instrumentation, sensors/transducer, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc. at Type 1 stations : 08 ( i) Chennai, ii) Mahabalipuram, iii) Puducherry, iv) Pandiyan Tivu, v) Manappad Point, vi) Kuthenkuli, vii) Kanyakumari, viii) Muttom Point) |
| 106 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc . at Type 2 stations : 12 ( i) Pulicat, ii) Kadapakkam, iii) Portonovo, iv) poompuhar, v) Karaikal, vi) Nagapattinam, vii) Kodikarai, viii) Mallipattinam, ix) Ammapattinam, x)Passipattinam, xi) Kilakkarai, xii) Vembar ) |
| 107 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, cabling, wiring, power supplies, software, cabling, wiring etc . – Type 3 stations : 03 ( i) Cuddalore, ii) Pamban, iii) Olakuda ) |
| 108 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc . at Type 4B stations : 02 i)Point Calimere) ii)Dhanushkodi |
| 109 | Work Stations with 27” LED Monitor, printer( All in One multifunction machine A4 size ) and associated software at all RCS (02 work stations each at 05 RCS) specifications as per section 6.9 |
| 110 | Work Stations with 27” LED Monitor, printer( All in One multifunction machine A4 size) and associated software (02 work stations ) specifications as per section 6.9 |
| 111 | Data base server (Comprises with Webservice facility) with necessary Router/hardware/software including Firewall etc (02 redundant server Main/Standby) The Firewall/router shall have at least two spare ports for future use specifications as per section 6.9 |
| 112 | Suitable mounting server rack for mounting data base server at MCS.(01 rack at MCS ) |
| 113 | 8 Port KVM Switch 01 |
| 114 | 55” LED Monitor specifications as per section 6.9 |
| 115 | 16 Port Ethernet network layer Switch (01 switch at 01 MCS & 05 RCS) |
| 116 | Supply and Installation of necessary hardware/software including GSM SIM/FTTH Communication terminals/system including antenna systems & associate data integration devices (modem, power supplies etc) and Airtime/Bandwidth/internet Charges during 03 years warranty period(25 sites (19 RS+ 01 MCS+ 04 (RS +RCS) + 01 RCS Rameshwaram) |
| 117 | Microwave Communication Devices including antenna systems & associate data integration devices (modem, power supplies etc) for Type4B Stations |
| 118 | Supply and Installation of VoIP phones including adaptors, cables and other required accessories, configuration etc |
| 119 | Solar Power System for Independent Operation of the Remote Control and Monitoring System at Remote Terminal Unit with autonomy of 03 day at Type 4A & 4B locations including Solar Panels, VRLA batteries, Charge Controller, Cables, wiring, Mounting Stands (all metal fabrication shall be galvanized), Junction Boxes, etc. (02 stations) |
| 120 | 03 KVA online UPS with battery for 60 mins backup at full load at RCS (01 each at 05 RCS) |
| 121 | 06 KVA online UPS with battery for 60 mins backup at full load ( 01 at each MCS Chennai Directorate) |
| 122 | Protection devices at each site , specifications as per Section 6.6)i) Isolation Transformersii) Surge protection for each phase at each site(23 Type 1, 2 & 3 Llighthouses, 05 RCS and 01 MCS) |
| 123 | Lightning Arrester complete system with proper Earthing (specfification as per sec 6.6 ) facility for each site for all outdoor installations Type 4A & 4C Lighthouses |
| 124 | Earthing with standard copper strip, copper plate and wire as per the specification, at each site separately (for Remote Monitoring Equipment and solar power plant for RCMS Equipment), specifications as per section 6.6 31 sites (25 RS+01 MCS+05 (RCS+RS)) |
| 125 | System technical manual, operation and maintenance/service manuals 07 set {01 for MCS 05 for RCS and 01 for HQs, Noida Library} |
| 126 | Standard Make Computer Table (02 tables each at 01 MCS & 05 RCS) |
| 127 | Standard Make Revolving chair (02 chairs each at 01 MCS & 05 RCS) |
| 128 | Standard Make 1.5 Ton Split invertor AC 5 star rating {latest Model 2023/2024} with copper condenser 02 A/Cs at each site. (01 MCS & 05 RCS) |
| 129 | Training as per para 6.15 |
| 130 | Safe removal and dismantling of existing system at all the sites |
| 131 | Buy Back of all the removed items from all the sites |
| 132 | Additional items 1 The description/ requirement of the product will be discussed in the pre-bid meeting and accordingly bidders may quote their price) |
| 133 | Additional items 2 (The description/ requirement of the product will be discussed in the pre-bid meeting and accordingly bidders may quote their price) |
| 134 | Standard make Laptop (i7 processor with 32 GB RAM or higher, Pre loaded Windows 11 Pro or latest, 1 TB SSD, minimum 04 USB port, ethernet port) loaded with all software for programming of PLC (01 at MCS Chennai) |
| 135 | 5kg capacity CO2 type fire extinguisher with fixture 01 No each for RCS and MCS |
| 136 | Comprehensive annual maintenance contract (CAMC) for 26 RS, 05RCS and 01 MCS for Seven years including all spares (hardware/software) and equipments of VSAT/GSM/FTTH/ Microwave/Lease Line(as applicable) |
| 137 | Airtime/Bandwidth/internet Charges during Seven years Comprehensive annual maintenance contract (CAMC) period of VSAT/GSM/FTTH/Microwave/Lease Line(as applicable) for 26 RS, 05RCS and 01 MCS. |
| 138 | Visakhapatnam Directorate (Supply, Installation, Integration, Testing and Commissioning of all items including Three Years Warranty and Seven years CAMC as applicable) |
| 139 | Remote Terminal Units consisting of instrumentation, sensors/transducer, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc. at Type 1 stations : 09 ( i) Santapalli, ii) Dolphin’s Nose,iii) Pudimadaka, iv) Pentakota, v) Vakalapudi, vi) Sacramento, vii) Antervedi , , viii)Vodarevu, ix) Krishnapatnam ) |
| 140 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc . at Type 2 stations :05 i) Machilipatnam, ii) Nizampatnam, iii) Ramayapatnam,iv) Isakapalli,v) Armagon) |
| 141 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, cabling, wiring, power supplies, software, cabling, wiring etc . – Type 3 stations : 02 ( i) Bheemunipatnam, ii) Ravaport) |
| 142 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, power supplies, software , cabling, wiring etc . at Type 4B stations : 01 i)Nagayalanka |
| 143 | Work Stations with 27” LED Monitor, printer ( All in One multifunction machine A4 size ) and associated software at all RCS (02 work stations each at 03 RCS ), specifications as per section 6.9 |
| 144 | Work Stations with27” LED Monitor, printer (All in One multifunction machine A4 size ) and associated software (02 work stations at MCS) , specifications as per section 6.9 |
| 145 | Data base server (Comprises with Webservice facility) with necessary Router/hardware/software including Firewall etc (02 redundant server Main/Standby at MCS ) The Firewall/router shall have at least two spare ports for future use. specifications as per section 6.9 |
| 146 | Suitable mounting server rack for mounting data base server at MCS.(01 rack at MCS ) |
| 147 | 8 Port KVM Switch 01 at MCS |
| 148 | 55” LED Monitor at MCS ,specifications as per section 6.9 |
| 149 | 16 Port Ethernet network layer Switch (01 switch at 01 MCS & 03 RCS) |
| 150 | Supply and Installation of necessary hardware/software including GSM SIM/FTTH/Leased Line/Microwave Communication terminals/system including antenna systems & associate data integration devices (modem, power supplies etc) and Airtime/Bandwidth/internet Charges during 03 years warranty period (16 sites (12 RS+01 MCS+ 03 (RS+RCS)) |
| 151 | VSAT Communication Devices including VSAT Airtime Charges, other charges etc. till the end of warranty period for Nagayalanka and Armagon Stations |
| 152 | Supply and Installation of VoIP phones including adaptors, cables and other required accessories, configuration etc |
| 153 | Solar Power System for Independent Operation of the Remote Control and Monitoring System at Remote Terminal Unit with autonomy of 03 day at Nagayalanka LH including Solar Panels, VRLA batteries, Charge Controller, Cables, wiring, Mounting Stands (all metal fabrication shall be galvanized with 90microns), Junction Boxes, etc. (01 stations) |
| 154 | 03 KVA online UPS with battery for 60 mins backup at full load at RCS (01 each at 03 RCS) |
| 155 | 06 KVA online UPS with battery for 60 mins backup at full load ( 01 at MCS ) |
| 156 | Protection devices at each site, specifications as per Section 6.6i) Isolation Transformers ii) Surge protection for each phase (16 Type 1, 2 & 3 Llighthouses, 03 RCS and 01 MCS) |
| 157 | Lightning Arrester complete system with proper Earthing (specfication as per sec 6.6) facility for outdoor installation at Nagayalanka Lighthouse |
| 158 | Earthing with standard copper strip, copper plate and wire, at each site separately (for Remote Monitoring Equipment and solar power plant for RCMS Equipment), specifications as per section 6.621 sites (17 RS+01 MCS+03 RCS) |
| 159 | System technical manual, operation and maintenance/service manuals 05 set {01 for MCS 03 for RCS and 01 for HQs, Noida Library} |
| 160 | Standard make Computer Table (02 tables each at 01 MCS & 03 RCS) |
| 161 | Standard make Revolving chair (02 chairs each at 01 MCS & 03 RCS ) |
| 162 | Standard make 1.5 Ton Split invertor AC 5 star rating {latest Model 2024} with copper condenser 02 A/Cs at each site. (01 MCS & 03 RCS) |
| 163 | Training as per para 6.15 |
| 164 | Safe removal and dismantling of existing system at all the sites |
| 165 | Buy Back of all the removed items from all the sites |
| 166 | Additional items 1 (The description/ requirement of the product will be discussed in the pre-bid meeting and accordingly bidders may quote their price) |
| 167 | Additional items 2 (The description/ requirement of the product will be discussed in the pre-bid meeting and accordingly bidders may quote their price) |
| 168 | Standard make Laptop (i7 processor with 32 GB RAM or more, Pre loaded Windows 11 Pro or latest, 1 TB SSD, minimum 04 USB port, ethernet port) loaded with all software for programming of PLC (01 at MCS Visakhapatnam) |
| 169 | 5kg capacity CO2 type fire extinguisher with fixture 01 No each for RCS and MCS |
| 170 | Comprehensive annual maintenance contract (CAMC) for 17 RS, 03 RCS and 01 MCS for Seven years including all spares (hardware/software) and equipments of VSAT/GSM/FTTH/Microwave/Lease Line (as applicable) |
| 171 | Airtime/Bandwidth/internet Charges during Seven years Comprehensive annual maintenance contract (CAMC) period of VSAT/GSM/FTTH/Microwave/Lease Line (as applicable) for 17 RS, 03RCS and 01 MCS. |
| 172 | Kolkata Directorate (Supply, Installation, Integration, Testing and Commissioning of all items including Three Years Warranty and Seven years CAMC as applicable) |
| 173 | Remote Terminal Units consisting of instrumentation, sensors/transducer, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc. at Type 1 stations : 05 i) Sagar Island, ii) Dariapur, iii) False Point, iv) Chandrabhaga, v) Gopalpur) |
| 174 | Remote Terminal Units consisting of instrumentation, sensors, PLC, HMI, Control Panel, power supplies, software, cabling, wiring etc . at Type 2 stations : 06 i) Tajpur, ii) Paradip, iii) Puri, iv) Prayagi, v) Baruva, vi) Kaligapatnam) |
| 175 | Work Stations with 27” LED Monitor, printer ( All in One multifunction machine A4 size ) and associated software at all RCS (02 work stations each at 03 RCS) specifications as per section 6.9 |
| 176 | Work Stations with 27” LED Monitor, printer ( All in One multifunction machine A4 size ) and associated software (02 work stations at MCS) specifications as per section 6.9 |
| 177 | Data base server (Comprises with Webservice facility) with necessary Router/hardware/software including Firewall etc (02 redundant server Main/Standby at MCS) The Firewall/router shall have at least two spare ports for future use. specifications as per section 6.9 |
| 178 | Suitable mounting server rack for mounting data base server at MCS.(01 rack at MCS ) |
| 179 | 8 Port KVM Switch 01 |
| 180 | 55” LED Monitor at MCS specifications as per section 6.9 |
| 181 | 16 Port Ethernet network layer Switch (01 switch at 01 MCS & 03 RCS) |
| 182 | Supply and Installation of necessary hardware/software including GSM SIM/FTTH Communication terminals/system including antenna systems & associate data integration devices (modem, power supplies etc) and Airtime/Bandwidth/internet Charges during 03 years warranty period. (12 sites (08 RS+01 MCS+ 03 (RS+RCS)) |
| 183 | Supply and Installation of VoIP phones including adaptors, cables and other required accessories, configuration etc |
| 184 | 03 KVA online UPS with battery for 60 mins backup at full load at RCS (01 each at 03 RCS) |
| 185 | 06 KVA online UPS with battery for 60 mins backup at full load ( 01 at each MCS) |
| 186 | Protection devices at each site (specifications as per Section 6.6) i) Isolation Transformers ii) Surge protection for each phase (11 Type 1 & 2 Llighthouses, 03 RCS and 01 MCS) |
| 187 | Earthing with standard copper strip, copper plate and wire, at each site separately (for Remote Monitoring Equipment and solar power plant for RCMS Equipment), specifications as per section 6.615 sites (11 RS+01 MCS+03 RCS) |
| 188 | System technical manual, operation and maintenance/service manuals 05 set {01 for MCS 03 for RCS and 01 for HQs, Noida Library} |
| 189 | Standard make Computer Table (02 tables each at 01 MCS & 03 RCS) |
| 190 | Standard make Revolving chair (02 chairs each at 01 MCS & 03 RCS ) |
| 191 | Standard make 1.5 Ton Split invertor AC 5 star rating {latest Model 2024} with copper condenser 02 A/Cs at each site. (01 MCS & 03 RCS under Kolkata Directorate) |
| 192 | Training as per para 6.15 |
| 193 | Safe removal and dismantling of existing system at all the sites |
| 194 | Buy Back of all the removed items from all the sites |
| 195 | Additional items 1 (The description/ requirement of the product will be discussed in the pre-bid meeting and accordingly bidders may quote their price) |
| 196 | Additional items 2 (The description/ requirement of the product will be discussed in the pre-bid meeting and accordingly bidders may quote their price) |
| 197 | Standard make Laptop (i7 processor with 32 GB RAM or more, Pre loaded Windows 11 Pro or latest, 1 TB SSD, minimum 04 USB port, ethernet port) loaded with all software for programming of PLC (01 No. each for MCS Kolkata and MNTI Kolkata) |
| 198 | Providing 01 Complete set of type 1 RTU (Service room and Power room units including sensors) to MNTI Kolkata for training purposes. The system should work as a model Remote Control and Monitoring system. |
| 199 | 5kg capacity CO2 type fire extinguisher with fixture 01 No each for RCS and MCS |
| 200 | Comprehensive annual maintenance contract (CAMC) for 11 RS, 03 RCS, 01 MCS and 01 Complete set of type 1 RTU to MNTI Kolkata for training purposes for Seven years including all spares (hardware/software) and equipments of VSAT/GSM/FTTH/Microwave/Lease Line (as applicable) |
| 201 | Airtime/Bandwidth/internet Charges during Seven years Comprehensive annual maintenance contract (CAMC) period of VSAT/GSM/FTTH/Microwave/Lease Line (as applicable) for 11 RS, 03 RCS, 01 MCS and 01 Complete set of type 1 RTU to MNTI Kolkata for training purposes |
| 202 | Development of web based / Mobile centralized dashboard (Android/iOS for automatic fault detection and complaint logging system as described in Section 6.2 of tender document Please Enable Macros to View BoQ information |