Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | H.S.R. Item |
| 2 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (16 Sqmm size) |
| 3 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (25 Sqmm size) |
| 4 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (35 Sqmm size) |
| 5 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (70 Sqmm size) |
| 6 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (120 Sqmm size) |
| 7 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (150 Sqmm size) |
| 8 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (185 Sqmm size) |
| 9 | COPPER CABLE: Supply, erection, testing and commissioning of IS marked 3 core Copper Cables, Solid Copper conductor up to 6sqmm and balance Stranded Copper, XLPE Insulated, cores laid up, PVC Inner sheathed, Armoured (Glavanised wire for cables up to 10x1.5sqmm, 8x2.5sqmm, 2x10sqmm, 3x10sqmm, 4x6sqmm and balance all galvanized steel strip), extruded PVC type ST2 Outer Sheathed, /1100 V grade as per IS 7098 (Part 1) 1988 with up to date amendments along with all accessories like thimble lugs etc for motors as per entire satisfaction of Engineer-in-charge complete in all respect. Make:Finolex / Havells / RR Cables. (95 Sqmm size) |
| 10 | Providing and fixing of 15 mm nominal diameter water meter as per IS 779:1994 Inferential type dry dial, mechanical driven, non megnatic drive, straight reading cyclometer type, 7-inline consequent digits with one centre point for easy reading complete in all respect. |
| 11 | Less credit for old Good bricks 583.09 x 60% = 350 @ 480 brick per = 167931 |
| 12 | Less credit for old bricks bats @ 40% (Per Cum) Total 583.09 x 40% = 233.24 |
| 13 | Less credit for old Good bricks 743.98 x 60% = 446 @ 480 brick per = 214265 |
| 14 | Less credit for old bricks bats @ 40% ( Per Cum ) Total 743.98 x 40% = 297.59 |
| 15 | `RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 8400 LPM x 15.00 M (At 1st W/W for WTP-1) |
| 16 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 25 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (At 1st W/W for WTP-2 for R/W) |
| 17 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 47.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (At 1st W/W for WTP-1 for R/W) |
| 18 | Providing and laying Double Flanged (Screwed/ Welded) Centrifugally (Spun) cast Iron, class B (IS 1536) complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion etc up to the site of work.350 mm nominal diameter |
| 19 | Providing, fixing, jointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site. 150 mm nominal diameter |
| 20 | Providing, fixing, jointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site. 200 mm nominal diameter |
| 21 | Providing, fixing, jointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site. 250 mm nominal diameter |
| 22 | Providing, fixing, jointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site. 300 mm nominal diameter |
| 23 | Providing, fixing, jointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site. 350 mm nominal diameter |
| 24 | Providing, fixing, jointing, testing of Mechanical joints complete with rubber gaskit, Galvanized nuts and bolts including labor, tranportaion ets up to the site. 100 mm nominal diameter |
| 25 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 12.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For D.C Colony B/Stn.) |
| 26 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 5 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Charanjiv Colony B/Stn.) |
| 27 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 20 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Ram Nagar B/Stn.) |
| 28 | Less credit for old Good bricks 11.67 x 60% = 7 @ 480 brick per cum = 3361 |
| 29 | Less credit for old bricks bats @ 40% ( Cum )Total 11.67 x 40% = 4.67 |
| 30 | Less credit for old Good bricks 50.81 x 60% = 30 @ 480 brick per cum = 14632 |
| 31 | Less credit for old bricks bats @ 40% ( Cum )Total 50.81 x 40% = 20.32 |
| 32 | Less credit for old Good bricks 23.05 x 60% =13.83 @ 480 brick per cum = 6637 |
| 33 | Less credit for old bricks bats @ 40% ( Cum )Total 23.05 x 40% = 9.22 |
| 34 | Less credit for old Good bricks 32.99 x 60% =19.79 @ 480 brick per cum = 9501 |
| 35 | Less credit for old bricks bats @ 40% ( Cum )Total 32.99 x 40% =13.20 |
| 36 | Less credit for steel bars from RCC cover slab @ 70 kg ( Cum ) |
| 37 | ` SERVER GRADE HARDWAREs IPC 1 No. Desktop Intel core i9 processor 16 GB RAM 512GB SSD(HP/Dell) 2 x Ethernet Port ,Windows 10 Professional or latest operating systems with MS office 1 No. 36” INCH SCREEN DISPLAY (LG/SAMSUNG) 1 No. SCADA LICENSE KEY 2500 TAGS1 No.UPS 600 VA (Microtek/Luminous/Su-kam) 1 No. PRINTER COLOR A3 Inkjet (HP/EPSON) ` |
| 38 | `PLC HMI SYTEM , ENCLOSURE and ACCESORIES:- AUTOMATION OF Clear Water Pump House -PLC and HMI SYSTEM consisting of 1 No. PLC, 1 No. HMI 7 inch, 1 No. IOT MODULE-CLOUD GATEWAY -1 No. POWDER COATED CNC FABRICATED ENCLOSURE- ENCLOSURE- ACCESSORIES- 100 Nos. TERMINAL BLOCK , 1No. SMPS , 1 No. FAN and FILTTERS , 200 m CONTROL WIRING , 4 No. Relay Cards, 1 No.ISOLATION TRANSFORMER 500 VA , 3 Nos. PUSH BUTTON and INDICATORS , 1 No. LED LIGHT , 1 No. PVC CHANNELS, 1 No. SURGE PROTECTION DEVICE, 1 No.DIN RAILS, and MISC ACCESSORIES NUT, BOLTS, HINGES AND OTHER MECHINCAL ACCESSORIES and MANUFACTURING complete- At Automation of Clear Water Pump House.` |
| 39 | Pressure transmitter. |
| 40 | Electromagnetic Flow meter of Max 350 mm Dia, 4-20mA output and RS-485 communication at outlet from clear water pump House. |
| 41 | Electromagnetic Flow meter of 350 mm Dia, 4-20mA output and RS-485 communication at outlet from Direct Distribution. |
| 42 | Electrically operated actuated sluice valve of max 350 mm dia. |
| 43 | `Residual chlorine analyzer with 4-20mA output and RS-485 communication.` |
| 44 | `Ultrasonic Level transmitter at Clear water tank ( Clear Water Tank 1 Nos).` |
| 45 | `PLC HMI SYTEM , ENCLOSURE and ACCESORIES: -PLC and HMI SYSTEM consisting of 1 No. PLC, 1 No. HMI 7 inch, 1 No. IOT MODULE-CLOUD GATEWAY -1 No. POWDER COATED CNC FABRICATED ENCLOSURE- ENCLOSURE- ACCESSORIES- 250 Nos. TERMINAL BLOCK , 1No. SMPS , 1 No. FAN and FILTTERS , 400 m CONTROL WIRING , 10 No. Relay Cards, 1 No. ISOLATION TRANSFORMER 500 VA , 3 Nos. PUSH BUTTON and INDICATORS , 1 No. LED LIGHT , 1 No. PVC CHANNELS, 1 No. SURGE PROTECTION DEVICE, 1 No.DIN RAILS, and MISC ACCESSORIES NUT, BOLTS, HINGES AND OTHER MECHINCAL ACCESSORIES and MANUFACTURING complete including transportation and other charges- At Automation for Water Treatment Plant (5.00 MLD)` |
| 46 | `Ultrasonic Flow meter for open channel, 4-20mA output and RS-485 communication for WTP` |
| 47 | `pH meter, Turibity analyzer with 4-20mA output and RS-485 communication at WTP` |
| 48 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 20 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Govt. College B/Stn.) |
| 49 | Providing and fixing of CI sluice valves conform to IS1 4846 / DIN 3352,with length over flanges as per PDorALT1ofIS14846 corresponding to BSEN – 558/ISO5752 Basic Series 3 and15 respectively including labour, material, joints. Make:IVC / VAG / Kirloskar complete in all respect as per specifications mentioned in DNIT (900 mm i/d) |
| 50 | Providing and fixing of CI sluice valves conform to IS1 4846 / DIN 3352,with length over flanges as per PDorALT1ofIS14846 corresponding to BSEN – 558/ISO5752 Basic Series 3 and15 respectively including labour, material, joints. Make:IVC / VAG / Kirloskar complete in all respect as per specifications mentioned in DNIT (700 mm i/d) |
| 51 | Level Switches at different tanks (Alum Dosing Tank- 2 Nos, Sludge Sump 1 Nos., Service Tank 1 Nos., CWT -1 Nos., Filter-4 Nos.) at WTP 5.00 MLD |
| 52 | `Electrically operated actuated valve of max 350mm dia (Floculator Chamber- 1 Nos, Mixing Chamber- 1 No., Influent to Filter bed-4 No., Effluent clear Water -2 Nos, Effluent Back Washed Water - 1Nos.,Service tank For Back Wash - 1Nos., Air Blower - 2 Nos.) at WTP 5.00 MLD` |
| 53 | Loss of head Transmitter with 4-20mA output (4 Nos. Filter bed each WTP) at WTP 5.00 MLD |
| 54 | Electromagnetic Flow meter of Max 500 mm Dia, 4-20mA output and RS-485 communication at outlet from clear water pump House. |
| 55 | Electromagnetic Flow meter of 500 mm Dia, 4-20mA output and RS-485 communication at outlet from Direct Distribution. |
| 56 | Electrically operated actuated sluice valve of max 500 mm dia. |
| 57 | `PLC HMI SYTEM , ENCLOSURE and ACCESORIES: -PLC and HMI SYSTEM consisting of 1 No. PLC, 1 No. HMI 7 inch, 1 No. IOT MODULE-CLOUD GATEWAY -1 No. POWDER COATED CNC FABRICATED ENCLOSURE- ENCLOSURE- ACCESSORIES- 250 Nos. TERMINAL BLOCK , 1No. SMPS , 1 No. FAN and FILTTERS , 400 m CONTROL WIRING , 10 No. Relay Cards, 1 No. ISOLATION TRANSFORMER 500 VA , 3 Nos. PUSH BUTTON and INDICATORS , 1 No. LED LIGHT , 1 No. PVC CHANNELS, 1 No. SURGE PROTECTION DEVICE, 1 No.DIN RAILS, and MISC ACCESSORIES NUT, BOLTS, HINGES AND OTHER MECHINCAL ACCESSORIES and MANUFACTURING complete including transportation and other charges- At Automation for Water Treatment Plant (10.00 MLD)` |
| 58 | Level Switches at different tanks (Alum Dosing Tank- 2 Nos, Sludge Sump 1 Nos., Service Tank 1 Nos., CWT -1 Nos., Filter-4 Nos., Sedimentation Tank- 6 Nos.) at WTP 10.00 MLD |
| 59 | `Electrically operated actuated valve of max 500mm dia (Floculator Chamber- 1 Nos, Mixing Chamber- 1 No., Influent to Filter bed-4 No., Effluent clear Water -2 Nos, Effluent Back Washed Water - 1Nos.,Service tank For Back Wash - 1Nos., Air Blower - 2 Nos.) at WTP 10.00 MLD` |
| 60 | Loss of head Transmitter with 4-20mA output (4 Nos. Filter bed each WTP) at WTP 10.00 MLD |
| 61 | `ACB: supply, installation and commissioning of 800A, 4 pole, 50KA ACB Rated Operational Voltage: Typically 415V, Rated Insulation Voltage: 1000V, Rated Impulse Withstand Voltage: 8 kV for main circuit, Breaking Capacity: 50 kA to 100 kA., Short Circuit Breaking Current (Icu): = 50 kA/sec., Rated Service Breaking Capacity (Ics): 100% of Icu., Rated Short Time Withstand Current (Icw): 100% of Icu., Tripping Type: Numeric/Advance type., Protection Type: Overload (O/L) and Earth Fault (E/F) protection (microprocessor based)., Operation Type: Manual and Electrical., Number of Poles: 4 Pole.,Frequency: 50Hz ± 3%., Standards: IS: 13947-2, IEC 60947-2., Auxiliary Switches: Minimum 5 NO plus 5 NC., Fixed Contacts: VR and HR combination., Metering and Monitoring: Built-in metering and monitoring capabilities to analyze real-time performance and health. ` |
| 62 | `VCB Panel: Supply Indoor Type 11KV VCB Control Cubical Panel with vertical Isolation Type Breaker as per Relevant IS as amended up to Date and Additional Specifications, having Capacities as Mentioned Below, Single break trip free mechanism, manually charged and Auto/Manually closing breaker suitable for use on 11kv, 3 phase 50hz AC, Supply with short circuit fault level of 500 Amps Capacity, breaker featured with local ON/OFF indicator with hand trip device, spring release coil, shunt trip coil and auxiliary switch of 2NO plus 2NC and equipped with following switchgears and accessories including making suitable structure arrangement for installation, control wiring and connections etc. as reqd. (1 IC plus 2 OG)a). VCB, 11KV, 630Amp, 50KA.b). 1ph 11KV/110 Volts PT (indoor type) Class 0.2 Accuracy and 100 VA burden -3 no’s.c). 33KV indoor dead type dual core dual ratio 3CTs of ratio 200-100/5-5 A of 15 VA burden, PS 5 P10 and accuracy class 0.2.d). Control panel- Cubicle type control panel suitable for floor mounting made out of 1.63 mm CR sheet duly powder coated and with following relays.e). Microprocessor based numerical relay for O/L, E/F and SC Protection suitable for above.f). Master trip relay -2 no’s.g). Indicator type Annunciator panel with buzzer.h). Digital Volt Meter- 0-11 KV.i). Digital Amp Meter- 0-100 Amp.j). RYB/ Trip/Closing/Spring charged indicator lamp.k). Fault Annunciator panel for O/L, WTI, OTI and Buchhloz Relay Alarm And Trip Auxiliary relay.l). TNC Switch for Operation.m). Multifunction Meter EM6400NG.n). TCS Relay for Safe` |
| 63 | Credit of existing outlived pump sets. (At 1st W/W and its B/Stn.)At 1st water works for WTP-1 (R/W pump) - 2 no. (30 HP) At 1st water works for WTP-2 (R/W pump) - 2 no. (30 HP) At 1st water works for WTP-1 (C/W pump) - 3 no. (150 HP) At 1st water works for WTP-2 (C/W pump) - 2 no. (100 HP) At 1st water works for WTP-3 (C/W pump) - 3 no. (150 HP)B/Stn. - 5 (D.C. Colony) - 2 no. (20 HP) B/Stn. - 10 (Vidya Nagar) - 2 no. (27.50 HP)B/Stn. - 25 (Nehru Park) - 2 no. (75 HP) B/Stn. - 26 (Chiranjiv Colony) - 2 no. (50 HP) B/Stn. - 27 (Ram Nagar/BTM BS) - 2 no. (40 HP)B/Stn. -31 (Vikas nagar) - 2 no. (60 HP)B/Stn. -8 (Lohar Bazar) - 2 no. (75 HP) |
| 64 | Credit of existing outlived Panel Boards and cables etc. (At 1st W/W and its B/Stn.)At 1st water works for WTP-1 (R/W pump) - 2 no. (30 HP) At 1st water works for WTP-2 (R/W pump) - 2 no. (30 HP) At 1st water works for WTP-1 (C/W pump) - 3 no. (150 HP) At 1st water works for WTP-2 (C/W pump) - 2 no. (100 HP) At 1st water works for WTP-3 (C/W pump) - 3 no. (150 HP)B/Stn. - 5 (D.C. Colony) - 2 no. (20 HP) B/Stn. - 10 (Vidya Nagar) - 2 no. (27.50 HP)B/Stn. - 25 (Nehru Park) - 2 no. (75 HP) B/Stn. - 26 (Chiranjiv Colony) - 2 no. (50 HP) B/Stn. - 27 (Ram Nagar/BTM BS) - 2 no. (40 HP)B/Stn. -31 (Vikas nagar) - 2 no. (60 HP)B/Stn. -8 (Lohar Bazar) - 2 no. (75 HP) |
| 65 | Less credit for old Good bricks 364.32 x 60% = 218.59 @ 480 brick per cum = 104924 Bricks |
| 66 | Less credit for old bricks bats @ 40% ( Cum ) Total 364.32 x 40% = 145.73 Cum |
| 67 | Less credit for old Good bricks 13.12 x 60% = 7.87 @ 480 brick per cum = 3779 |
| 68 | Less credit for old bricks bats @ 40% ( Cum )Total 13.12 x 40% = 5.25 |
| 69 | Less credit for old Good bricks 10.79 x 60% = 6.47 @ 480 brick per cum = 3107 |
| 70 | Less credit for old bricks bats @ 40% ( Cum )Total 10.79 x 40% = 4.31 |
| 71 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 5700 LPM x 45.00 M Head (For Lohar Bazar B/Stn.) |
| 72 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 95 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Lohar Bazar B/stn.) |
| 73 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 5200 LPM x 50.00 M Head ( For Vidhya Nagar B/stn. ) |
| 74 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 97.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Vidhya Nagar B/STN.) |
| 75 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 8800 LPM x 40.00 M Head (For Nehru Park B/Stn.) |
| 76 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 132.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Nehru Park B/Stn.) |
| 77 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 6200 LPM x 40.00 M Head (For Vikas Nagar B/Stn.) |
| 78 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 92.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (For Vikas Nagar B/Stn.) |
| 79 | WTP: Design and construction of 11.00 MLD capacity Scada based water treatment plant including providing and laying the DI / CI pipes, specials, sluice valves from inlet chamber of WTP to inter connecting piping network in WTP (The cost of these DI / CI pipes, valves and specials shall also be included in the rates quoted by the contractor) along with inlet chamber, Alum dozing, Flash mixing, Clariflocculator, filter box, over head Reservoir for back wash and waste water tank with suitable size pumping sets and panel boards, air scour equipment, chemical house with chlorination equipments, all other civil, mechanical, electric installations complete in all respects as per specifications (make of Sluice valves / NRV: IVC / VAG / Kirlosker) 11.00 MLD Capacity (At 1st Water works) |
| 80 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 5900 LPM x 30.00 M Head (At 1st W/W for Line-2) |
| 81 | `CLEAR WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Clear water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 9700 LPM x 30.00 M Head (At 1st W/W for line-1) |
| 82 | `RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked` 9200 LPM x 15.00 M (At 1st W/W for WTP-3) |
| 83 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 110 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (At 1st W/W for line -1 for C/W) |
| 84 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 67.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (At 1st W/W for Line-2) |
| 85 | Design, Supply, installation and testing of VFD along with distribution panel in enclosure for motor rating of 52.50 HP. Enclosure shall be IP54. The panel shall be equipped with MCCB TP with suitable rating, Spreader link TP, Extended rotary handle, Volt meter digital, Volt selector switch, Amp meter, Amp selector switch, C.T with suitable rating, Control MCB SP with suitable rating, PLA Relay, Pushbutton red plus green with element, Indicator ON/Off, Aluminium Bus bar/suitable rating power and Control wiring labour and margin, Fabrication with minimum Sheet thickness of 2 mm for load bearing and non-load bearing side. VFD should be capable of protecting motor from high and low voltage and earth fault as well. VFD should restrict harmonics up to 35% VFD should be capable of providing starting torque up to 200% while starting motor. It should have class 3C3 (Avg)conformal coating so that components are safe from dust and moisture. Communication -Built-in RS485 Modbus RTU, Ambient Temperature -Heavy Duty: -10 ~ 50 deg C Normal Duty: -10 ~ 40 deg C, PCB Protection Conformal Coating complying to IEC 60721-3-3 class 3C3, Application Humidity Below relative humidity 95% RH (no condensation) Altitude 0 to 1,000 m Without deration 1,001 to 4,000 m With deration of 1% per rise in 100 m, Vibration Up to 9.8 m/sec2 (1.0 G), Global Compliance CE, UL, RoHS, Control Method V/F Control, Sensorless Vector Control, Slip Compensation, Closed Loop Vector Control. Starting Torque 200% at 0.5Hz in Sensorless Vector Control and 150% at 3Hz in V/F, Frequency Control Range 0 to 400Hz in V/F, 0 to 300Hz in Sensorless 1, 0 to 120Hz in Sensorless 2 / Vector, Frequency Precision Setting- Digital: 0.01Hz, Analog: 0.03Hz (60Hz Base). complete with all other accessories as required. (At 1st W/W for WTP-3 for R/W) |
| 86 | Less credit for old Good bricks 916.09 x 60% = 549.65 @ 480 brick per cum = 263833 |
| 87 | Less credit for old bricks bats @ 40% ( Cum ) Total 916.09 x 40% = 366.43 |
| 88 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 150 mm, installed at pump End / Source. (Inlet Flowmeter at 1st W/W B/Stns.: Ram Nagar) |
| 89 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 200 mm, installed at pump End / Source. (Inlet Flowmeter at 1st W/W B/Stns.: Chiranjiv Colony) |
| 90 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 250 mm, installed at pump End / Source. (Inlet Flowmeter at 1st W/W B/Stns.: D.C. Colony, Govt. College, Vikas Nagar) |
| 91 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 300 mm, installed at pump End / Source. (Inlet Flowmeter at 1st W/W B/Stns.: Vidhya Nagar) |
| 92 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 350 mm, installed at pump End / Source. (Inlet Flowmeter at 1st W/W B/Stns.: Nehru Park) |
| 93 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 400 mm, installed at pump End / Source. (Inlet Flowmeter at 1st W/W B/Stns.: Loahr bazar) |
| 94 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 200 mm, installed at pump End / Source. (outlet Flowmeter at 1st W/W B/Stns.: Ram Nagar, Chiranjiv Colony, D.c Colony) |
| 95 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 250 mm, installed at pump End / Source. (outlet Flowmeter at 1st W/W B/Stns.: Vikas Nagar) |
| 96 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 300 mm, installed at pump End / Source. (outlet Flowmeter at 1st W/W B/Stns.: Nehru Park, Vidhya Nagar, Govt. College) |
| 97 | Electromagnetic Flowmeter: Supply, Installation, testing, Commissioning five year maintenance, Electromagnetic Flowmeter along with its installation complete in all respect as per specifications. Size as per site requirement.(IP-68), RS-485 ModBus and 4-20mA output. Line size 350 mm, installed at pump End / Source. (outlet Flowmeter at 1st W/W B/Stns.: Vidhya Nagar, Lohar bazar) |
| 98 | Dismantling and relaying of old 600 mm i/d D.I R/W pipe for filling the tank no. 5 and 6 at 1st water works including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking joints, including stacking of pipes and lead at site within 50 meter lead as per direction of Engineer in-charge. |
| 99 | DI PIPE : Supply of Ductile iron (DI) ISI marked K9 (grade S and S pipes as per IS:8329-2000 (amended up to date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joint as per IS:5382-1985 (excluding special accessories) complete including all material, labor, hydraulic tsting and commissioning as per technical specifications and as per direction of Engineer. (Date: 8-12-2025) 300 mm i/d (Including 3% storage charges) ... |
| 100 | `RAW WATER PUMP: Supplying, erection, testing and commissioning of Horizontal motor pumping set for Raw water having head as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked ` 4200 LPM x 15.00 M (At 1st W/W for WTP-2) ... 25 BHP |
| 101 | Operation and Maintenance of old water works at meham road along with Proposed 11.00 MLD WTP as well as existing WTPs 10.00 MLD and 5.00 MLD capacity and their associated Civil Structures, Pumping Machineries, Head works pipelines, Civil/Electrical/Mechnical/IOT/IT/SCADA installations including Transformers and DG set inside the campus of Old water works Meham Road Bhiwani Town and Maintance/Repair of Pumping machineries/Electrical/Mechincal parts replaced under the scope ofwork at Boosters connected with Old Water works Meham RoadBhiwani Town (During 1st year of defect liablity period aftersuccessful trail run) |
| 102 | During 2nd year of defect liability period |
| 103 | During 3rd year of defect liability period |
| 104 | During 4th year of defect liability period |
| 105 | During 5th year of defect liability period |
| 106 | During 6th year of defect liability period Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail