| 1 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and as directed. |
| 2 | Excavating over areas, n.exc 1.5 m deep and getting out in hard and dense soil complete all as specified and as directed. |
| 3 | M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete all as specified and directed. |
| 4 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth foundation, or not exc 10 Sqm on plan & getting out in hard/dense soil complete all as specified and directed. |
| 5 | M&L for 100mm thick PCC 1:4:8 Type D-2 (Using 40mm graded stone aggregate as in sub base) complete all as specified and directed. |
| 6 | M&L for Rolling and consolidating formation surfaces in cutting with power roller 8-12 tonne complete all as specified and directed. |
| 7 | M&L for Moorum / red bajri filling in floors or pavings, laid in layers n.exc 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 8 | M&L for Hardcore / broken stone or boulders of gauge exc 63 mm but n exc. 100 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rolled/rammed to a true surface complete all as specified and directed. |
| 9 | M&L for 150mm thick PCC 1:4:8 Type D-2 (Using 40mm graded stone agg as in sub base) complete all as specified and directed. |
| 10 | M&L for Cement concrete work in pavement / hard standing of flexural strength 40 Kg/ square centimetre in field, using 400 Kg of cement per Cum thickness of concrete 25 cm or less including use of form work all as specified and directed. |
| 11 | M&L forming contraction (Dummy) joints 65mm deep 10mm wide, filled with sealing compound, grade `A' complete all as specified and as directed. |
| 12 | M&L for finishing surface of concrete Roads, hard standing, pavings etc.,by brooming complete all as specified and as directed. |
| 13 | Returning filing in including spreading levelling watering and well ramming in layers not exceeding 25 cm thick in hard/dense soil complete all as specified and directed. |
| 14 | Removing excavated material (soil) to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 15 | Supply , fabricate , transportation & installation of Non Inflammable Porta Cabin of Size 4.000 x 4.000 x 3.050 m ht at Eves and 3.660m at Center with double skin wall using 2 Nos 10mm thick cement bonded particle board (Bison panel or equivalent) and the cavity filled with 30 mm thick EPS Insulation sheet and total wall thickness is 50 mm, MS Box section Frame and truss structure, Pitched Type roof and Purlin , false ceiling, doors and windows false ceiling complete all as specified (in particular specification) and as directed. |
| 16 | S&F Rotational moulded polyethylene water storage tanks IS : 12701 - 1996 marked (cylindrical vertical with closed top) of 500 Ltrs capacity with and including 20mm dia Ball brass valve high pressure with polythene float and flu nut screwed for iron pipe or brass and fixed etc complete all as specified and as directed. |
| 17 | S&F Vitreous china wash down water closet pan (pedestal pattern) white including plastic water closet seat, black, closed pattern with flat bottom and cover and mild steel chromium or aluminised hinging device complete all as specified and directed. |
| 18 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed. |
| 19 | S&F in repair CP two way angle valve with wall flanges 15 mm bore, screwed down, screwed for iron pipe or for brass ferrule complete. |
| 20 | S&F Vitreous China wash basin, white, flat back, of size 550x400 mm excluding taps, waste chain and plug and porcelain stopper but including brackets and brass, 32 mm dia chromium plated waste fitting and 40 mm bore PVC waste pipe all as specified and directed by Engineer-in-Charge. |
| 21 | S&F CP Pillar taps fancy type 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks and fly-nuts, screwed for iron pipe,complete all as specified and directed. |
| 22 | S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 23 | S&F PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 24 | S&F 15 mm bore Bib taps, chromium plated, cast copper alloy, screwed down, screwed for iron pipe, complete all as specified and directed. |
| 25 | S&F 20 mm bore Gun-metal globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 26 | M&L PVC (SWR) floor trap 75mm dia plain with grating including jointing with solvent cement complete all as specified and directed. |
| 27 | S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints fixed to walls as in soil, waste and pipes including dismantling of old pipes complete all as specified and directed. |
| 28 | S&F 110 mm bore PVC (SWR) bends any radius provided with access door, complete all as specified and directed. |
| 29 | S&F 110 mm bore PVC (SWR) junction, single (Single T) equal or unequal provided with access door, complete all as specified and directed. |
| 30 | S&F 32mm dia PVC waste pipe to WHB complete all as specified and directed. |
| 31 | S&F Angle cock 15 mm bore fancy type chromium plated, with capstan head, high pressure, screwed down, screwed for iron pipe or for brass ferrule fixed to iron pipe complete all as specified and directed. |
| 32 | Supply & laying CPVC pipes 20 mm Outer dia, SDR 11 & Plain CPVC SDR 11 fitting on wall/ceiling or laying in floors complete all as specified and directed. |
| 33 | Supply & laying CPVC pipes 16 mm Outer dia, SDR 11 & Plain CPVC SDR 11 fitting on wall/ceiling or laying in floors complete all as specified and directed. |
| 34 | S&F low level flushing cistern PVC valveless, syphonic action type 10 ltrs capacity, white with inlet, ball valve, float and handle including brackets complete all as specified and directed. |
| 35 | Excavating in post holes (or similar holes) each not exceeding 0.5 Cum, getting out in hard/dense soil, and removing surplus soil to a distance not exceeding 50 m and making good surface complete all as specified and directed. |
| 36 | M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 37 | M&L for PCC 1:3:6 type C-2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete complete all as specified and directed. |
| 38 | S&F Rolled mild steel work conforming to Fe 410-W Gde E-250 quality 'A' as in stanchions, posts, with flange plates, caps, bases, splices, angle brackets, cleats and other connections all as specified and directed. |
| 39 | S&F Roof Trusses (framed), trussed, purlins, rails and fastenings and heavy bracket framing ( Beam, tee, angles, Channel or flat section) including distance pieces, cleats etc conforming to Fe 410-W Gde E-250 quality 'A' complete all as specified and directed |
| 40 | M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of Fe 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 41 | M&L Preparation of new or previously un treated surfaces of steel and iron surfaces of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome paint complete all as specified and directed. |
| 42 | M&L for Hard core of gauge n.exc 63 mm , with broken stone or boulders , deposited, spread and levelled in layers n.exc 15 cm thick, watered and well rammed to a true surface complete all as specified and as directed. |
| 43 | M&L for 75 mm thick plain cement concrete 1:2:4 type B- 1 using 20mm graded stone aggregate as in floors , paths, pavings etc surface finished even and smooth without using extra cement complete all as specified and as directed. |
| 44 | M&L for 10mm thick cement plaster (rendering) in CM 1:6 on fair faces of brick work, surfaces finished even and smooth without using extra cement complete all as specified and as directed. |
| 45 | M&L for preparation of newly plastered surfaces of wall and applying two coats of cement base paint over a coat of primer complete all as specified and directed |
| 46 | Removing excavated material (soil) to a distance n exc. 250 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed. |
| 47 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregates as in surface channels and drain complete all as specified and directed.Note:- Forming fair finished channel shall be measured & paid separately |
| 48 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitred/stopped ends etc complete all as specified and directed. |
| 49 | M&L for PCC (1:2:4) type B-1 using 20mm graded stone aggregate as in bed plate, coping etc slightly rounded angle as directed finished even and fair complete all as specified and directed. |
| 50 | M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregates as in concrete bed to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and directed. |
| 51 | M&L for 150mm dia Reinforced concrete pipes, Class NP3 laid and jointed complete with collars complete all as specified and directed. |
| 52 | M&L for rendering 15 mm thick on fair faces of brick work or concrete surface in CM 1:4 mixed with WPC, finished even and smooth without using extra cement complete all as specified and directed. |
| 53 | All as per ser No 10 above but on external faces in CM 1:4, finish even and smooth with out using extra cement complete all as specified and directed.Note for item No.52 & 53:- The WPC shall be measured & paid separately. |
| 54 | Supply only integral water proofing compound (ISI marked) |
| 55 | M&L for precast reinforced concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in manhole cover slab set in CM 1:4 including necessary form work complete all as specified and directed.Note:- The reinforcement shall be measured & paid separately. |
| 56 | M&L for Mild steel high strength TMT bars as in reinforcement 8mm dia cut to length bent to shape required including cranking. bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia (weight of binding wire will not be included and paid for separately) complete all as specified and directed. Please Enable Macros to View BoQ information |
| 57 | M&L for Mild steel high strength TMT bars as in reinforcement 8mm dia cut to length bent to shape required including cranking. bending spirally for hoping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.90mm dia (weight of binding wire will not be included and paid for separately) complete all as specified and directed. Please Enable Macros to View BoQ information |