| 1 | Supply, Installation, Testing and Commissioning of 'Solar Hot Water System' (Flat Plate Collector) based on indirect transfer of heat of capacity 500 LPD with electric back up including connection with(3 runs of 4 Sq mm PVC insulated Copper cable from DB to Solar panel) confirming to ISI. Note : Rates are deems to be included transport and shifted up to roof top of the building all as specified and directed. |
| 2 | Supply and laying 20 mm dia CPVC pipes (Hot & Cold type) SDR 11 & plain CPVC SDR 11 fittings on walls/trenches or laying in floors complete all as specified and directed. |
| 3 | Supply and laying 25 mm dia CPVC pipes (Hot & Cold type) SDR 11 & plain CPVC SDR 11 fittings on walls/trenches or laying in floors complete all as specified and directed. |
| 4 | S&F PP-R Ball valve (Brass inserted) of size suitable for 20 mm dia CPVC pipes complete all as specified and directed. |
| 5 | S&F PP-R Ball valve (Brass inserted) of size suitable for 25 mm dia CPVC pipes complete all as specified and directed. |
| 6 | S F 500 Ltrs capacity rotational moulded polethylene water storage tanks, three layers (cylindrical vertical with closed top), hoisted and fixed in position all as specified in SSR Part I connecting up pipes including 25 mm bore float valve pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms) with and including inlet and outlet nipple completeall as specified and directed. |
| 7 | S&F 15 mm bore bib taps cast copper alloy, fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.completeall as specified and directed. |
| 8 | S&F and testing factory made sheet metal enclosure for MCB DB SPL 2 way with out bus bar 240 volts with single door, IP - 43 protection duly fixed/concealed in wall complete and making good distrubed suefaces of wall floor etc including necessary connection lugging with copper lugs pin/ring type all as directed. |
| 9 | S & F MCB Single pole and neutral 240 volts any rating from 32 to 40 amps, with ruptuturing capacity 10 KA 'C' curve type including providing thimble for out going cables.completeall as specified and directed. |
| 10 | M & L for Mild steel work of grade Fe-290 (Grade E-165) in stand for water tank, of section angle , flats etc all as directed, framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary gusset plates, riveting etc. completeall as specified and directed. |
| 11 | M & L for preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer. |
| 12 | M & L for lagging to pipes used in internal water supply or plumbing all round with 25 mm thick bonded mineral wool performed SNAP ON pipe sections of density 144 kg/cum conforming to IS 9842 covered with chicken mesh wire netting 25 gauge with 0.01 aluminium foil complete all as specified and directed. |
| 13 | S & F 1100 volts grade 6 Sqmm twin core heavy duty cable PVC insulated aluminium conductor multi strand, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular from Elect pole to MCB DB.complete all as specified and directed. |
| 14 | S & F bracket for fixing of street light fittings bend to shape, made out of 32 mm dia GI pipe medium grade 1.5 mtr long fixed with and including two sets of MS clamps made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed. |
| 15 | S&F bracket for street light fitting made out of 40mm dia GI pipe light grade 1.2 mtr long each bent to required shape & size as directed by EIC & fixed to pole with and including flat iron clamps 02 Nos made out of 32X 6mm flat iron including GI nuts, bolts & washer and painting of clamps and street light fittings brackets with one coat of red oxide primer, one under coat and one finishing coat with aluminium paint complete all as specified and directed. |
| 16 | Excavating in trenches in any type of soil, n. exc. 1.5 m wide and n. exc. 1.5 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and n.exc 1.5 m in depth and getting out complete all as specified and directed. |
| 17 | Excavating in trenches in any type of soil n. exc. 1.5 m wide and exc. 1.5 m but n. exc.3 m in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n. exc. 10 sqm on plan and exc 1.5 m but n. exc. 3 m in depth and getting out complete all as specified and directed. |
| 18 | Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25 cm complete all as specified and directed. |
| 19 | Removing excavated material (soil) to a distance n.exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed. |
| 20 | Material and Labour for PCC 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed. |
| 21 | M & L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete/sunken floors all as specified and directed. |
| 22 | M&L for PCC 1:3:6 (nominal mix) type C-1 (using 20mm graded crushed stone aggregates) as in coping of pole including necessary form work complete all as specified and directed. |
| 23 | M & L for Sand cashioning to cable with dry fine sand intrenches 8 cm below the cable and 15 cm above the cable after laying.complete all as specified and directed. |
| 24 | Supply & laying Bricks in trenches laid flat, for cable protection well burnt sub class 'B' complete all as specified. |
| 25 | Supply and laying in trenches or fixed to wall/pole or passing through ducts or pipe, cable LT 1100 volts grade heavy duty, XLPE insulated , armoured heavy duty electric cable , with aluminium conductor of size 16 Sqmm x 4 core complete all as specified and directed. |
| 26 | Supply, fixing and testing 60 W LED street Light luminaire be made up of Pressure Die Cast aluminum housing IP 66 effeiceint protection with heat resistant toughned glass with indidual LED lenses complete with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree) . The luminaire shall be complete available CCT 6500K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED street light shell be top maintainable for easy maintenance. LED street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED street Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED street Light shall have power factor more than 0.95 complete all as specified and directed. |
| 27 | S & F LED street light fitting of 70 watts, 5700k, IP 66 IK-07 rating power factor >0.95, IK-08 having 120 lm/watt efficacy with invidual lens cover on each LED, rendering index > 70, 4 KV integrated surge protection, external 10 KV surge protection potted driver, tougned glass cover in high pressure die-cast powder coated aluminium housing and making connection using 3 core fleaxible copper cable complete all as specified and directed. |
| 28 | Supply, fixing and testing 72 W LED street Light luminaire, made of Pressure Die Cast aluminum housing IP 66 effeiceint protection with heat resistant toughned glass with indidual LED lenses complete with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree) . The luminaire shall be complete available CCT 6500K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED street light should be top maintainable for easy maintenance. LED street Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED street Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED street Light shall have power factor more than 0.95 including testing after installation complete all as specified and directed. |
| 29 | Supply, fixing and testing 150W LED Flood Light luminaire made up of Pressure Die Cast aluminum housing with black epoxy polyester powder coating for long life with excellent illumination and instant light with low temperatures (-10 degree to +50 degree) . The luminaire shall be complete available CCT 5700K, IP66 for Optical Compartment and Control Gear Compartment.The Optical compartment shall be covered with heat resistant toughened glass for safety.The LED Flood light should be top maintainable for easy maintenance. LED Flood Light shall use multiple LEDs to get sufficient light output from the luminaire. The LED Flood Light shall be of Integral type. The Input voltage range shall be 100V to 300V. The LED Driver shall be of isolated type with Constant Current Constant Voltage topology to ensure optimum driving of LEDs. The LED Flood Light shall have power factor more than 0.95 including testing after installation complete all as specified and directed. |
| 30 | Note for LED light fittings:- 1. Driver should be potted anti-vibration types.2. LM-79 and LM-80test report with lakh burning hours LED life from NABL lab shuld be provided.3. CRI ( Colour Rendering Index) of fixture shall be >70.4. System Lumen Efficiency shall be >100 Lm/W.5. 10 KV separate surge protection shall be provided as a part of fitting6. Lenses shall be modular type.7. PCB used shall be MC PCB type.9. CA No shall be written on each fitting before installation.8. The Name of Manufacturer to be emborssed on the fitting.9. The fittings shall have arrangement so that maintenance required, if any can be carried out from top cover. 10.The defect libility period of LED lights shall be 05 years from the certified date of completion and the contractor shall replace/ repair the defective fitting with in 07 days after handing over the replacement. 11. A guarantee of 05 years shall be provided by contractor, supported by OEM covered all parts of luminaire. Contractor shall deposit security on this account @ 5% of work done against these items otherwise the same shall be deducted from the dues payable to him in RAR/ Final Bill.12. T&P for fixsing of lights upto 30 Mtr Hight shall be provided by the contractor and the rate quoted shall include the cost thereof. 13. SMPS based Driver with lower THD (<10 )shall be potted anti-vibration types. |
| 31 | Supply & laying three core Aluminium conductor PVC insulated cable of size 6 sqmm FR multistranded 1100 volts grade passing through & including PVC conduit 25mm dia complete all as directed. |
| 32 | Supply and fixing automatic street light switch for LED street light using infrared sensor based nature switch for autmatic switching of street light, 415 volt, Three Phase 12-18 KW, outdoor type factory made IP-65 protection having nature switch operating should be based on natural light flux level and selector switch to change the mode of operation, supply indicator with SMC box and locking arrangement. The sensor along with power Contactor of cap up to 63 Amp and incoming and outloging MCB TPN cap upto 63 Amp with auto/manual operation and overvoltage/under voltage and overcurrent/protection,surge protection of 10 KV and auto trip & auto reset making arrangement incl internal wiring of copper cable FRLS 10 sqmm single core multistranded and mounted arrangement with clump and nut bolt on wall/poles , dust proof and temper proof complete with all accessories as required and provided by manufactorer. complete all as specified and directed. |
| 33 | S&F SPN 2 way sheet metal enclosures factory made DB double door 230 V AC, 50 Hz AC 200 Amp rated bus bar complete all as specified and directed |
| 34 | Supply and fixing MCB single pole and nuetral 40 Amps, 240 volts , B-series complete all as specified and directed. Please Enable Macros to View BoQ information |
| 35 | Supply and fixing MCB single pole and nuetral 40 Amps, 240 volts , B-series complete all as specified and directed. Please Enable Macros to View BoQ information |