| 1 | Dismantling of ACSR conductors. |
| 2 | Dismantling of earth wire . |
| 3 | Dismantling of cross arms of MS channel or angle sections etc complete. |
| 4 | Dismantling of insulator any type any size . |
| 5 | Taking down existing old U/S street light fitting of any type and make & capacity complete all as specified and directed. |
| 6 | Taking down existing old us street light bracket with clamp complete all as specified and directed. |
| 7 | Taking down existing old defective LT Panel / FP Box by disconnectiing its all elecetrical connections and by dismantelling foundation complete all as specified and directed. |
| 8 | Taking down existing old U/S LT Pole of any type by disconnectiing its all elecetrical connections and by dismantelling foundation complete all as specified and directed. |
| 9 | Excavation in trenches n.exc. 1.5 m wide and n.exc.1.5 m deep in any type of soil and forming bottom surfaces for laying of cable/ foundation of polescomplete all as specified and directed. |
| 10 | Excavation in trenches exc. 1.5 m deep and n.exc.1.5 m wide in any type of soil and forming bottom surfaces for foundation of poles complete all as specified and directed. |
| 11 | Supply & laying sand cushioning for cable protection in trenches 8 cm before laying of cable and 15 cm thick over the cable complete all as specified and ditected. |
| 12 | Supply & laying brick for protection of cable sub class 'B' laid dry flat across the cable with width equal to the length of whole bricks complete all as specified and ditected. |
| 13 | Returning filling in including spreading leveling watering and well ramming in layers n. exc. 25 cm complete all as specified and directed. |
| 14 | Removal surplus soil at a distance n. exc. 50 m and deposited where diredted at a lavel not exc. 1.50 m above the starting pont complete all as specified and directed. |
| 15 | Labour for boring, holes for inserting of 50/80 mm bore GI pipe under the road/hard standing or any other location not less than 1200 mm deeep complete all as specified and ditected. |
| 16 | M & L GI pipe 20 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed. |
| 17 | M & L GI pipe 40 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed. |
| 18 | M & L GI pipe 50 mm bore light grade fixed on pole/under road/on wall for protection of cable including all fittings complete all as specified and directed. |
| 19 | Supply,laying,jointing and testing XLPE insulated extruded PVC outer sheath and inner sheath galvanized steel armoured cable with aluminium conductor suitable for rated voltage of 1100 Volts grade conforming to IS 7089 (Pt I of 1988) laid in tranches/ pipe/duct/pole complete all as specified and directed size 50 sqmm 3.5 core. |
| 20 | All as per item No 19 above but size 25 Sqmm 3.5 core. |
| 21 | All as per item No 19 above but size 10 Sqmm 4 core. |
| 22 | Supply laying fixing or passing through pipe 1100 Voltage grade heavy duty cable with PVC insulated and sheathed aluminium conductor comfirming to relevent IS size 6 sqmm 2 core unarmoured and connecting to system complete all as specified and directed. |
| 23 | Supply and fix FRP, hot press moulded SMC pole box 295X255X120 mm mm comprising of 100 Ams aluminium bus bar 4 strips ( IP 55 protection ) with one MCB SP 6 Ams to be fixed inside the box and box will be clamped bottom of the pole with FI clamps (duly painted ) nut bolt washers of required size.Make - SINTEX or any other sample approved by GE. |
| 24 | S & F bracket made with GI tube light grade (not less than 1.2 RM) in length of 40 mm bore size and fixed to the LT pole with the help of two Nos FI Clamps of size 50X6 mm nut bolt and washers,complete all as specified and directed. |
| 25 | Supply and fix roadway luminaire LED light fittings of 90 watts and including necessary electric connection with 2.5 Sqmm twin core Copper conductor unarmoured cable, complete all as specified and directed. Make Bajaj /CG/Philips /Havells. |
| 26 | All as per item No 25 above but of 120 watts |
| 27 | Supply, erecting and fixing in true vertical position steel tubular swaged pole 9.0 Mtr long type (410 SP -31) conforming to IS 2713 part I & III - 1980 complete with cast iron base plate, pole cap, mild steel, bolts, nuts and screws, welded and reduced section and longitudinal weld seam throughtout entire length of pole including two coats of black bituminous paint throughtout internally and externally upto planting depth and remaining exterior portion of pole with two coats of aluminium paint over a coat of red oxide primer complete including transporting the poles to plating & providing three bends/strap with paint red signal/post office colour 300 mm apart from plinth block & numbering of poles complete all as specified and directed . Note:- Earth work & PCC will be measured and paid separately under respective item. |
| 28 | Dimolation and dimantling PCC ( unreinforced) of any description and in any position. |
| 29 | M&L for plain cement concrete 1:4:8 type D2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 30 | M&L for plain cement concrete 1:3:6 type C2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 31 | M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in coping, including necessary form work complete all as specified and directed. |
| 32 | Preparation of old painted steel surface and painting of steel tubular pole upto 09 metre long, applying two coats of aluminium paint on complete poles including cross arms and writing of numbers on pole with black paint in 40 mm font size of letters including surface dressing all around the poles approximetely 01 Sqm area complete all as specified and directed at site. |
| 33 | Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor,MCBs and copper circuit wiring (min.10sqmm) should enough to take: Three-phase load of 12-15KW;contactor Rating 32Amps; MCB(sp) Rating 32Amps.MAKE:-Nature switch :Kakatiya energy systems pvt.ltd. hyderabad/bajaj/healer. Contactor:- BCH/L&T/Schneider or equivalent (as per IEC-60947-4-1/IS-13947-4-1), MCBs(Input-output):Hager/schneider/L&T/BCH or equivalent (as per IEC-60898/IS-8828),Circuit wiring : Finolex/polycab/RR Kable or equivalent. Model no NAVDEEP--54-12KW3P |
| 34 | Supply, Installation, test and Commissioning factory fabricated, out door type,LT FEEDER PILLAR BOX Double Door , Both side openable made out of 3.15 mm thick CRCA Sheet of size 07MX0.6mX.35M with projected Globe roof for rain water protection duly treated through 8 tank pre treatment process and painted with epoxy powder coated mat finish of SIEMENS GREY structural RAL 7032 shade colour Dust and Vermin Proof , Double door with both side opening including Neoprene Rubber Gasket,, suitable for 440 Volt 3 Phase 4 Wire System ,including Danger Plate, Earthing Strip Point and Ventilation Louvers at Rear Side, Bottom detachable Gland Plate comp-lete with suitable size Zinc Chromium Plated Nuts, Bolts and Washers, etc. and embeded with 50X50X6mm Mild Steel Angle Iron Frame and 600 mm above the Normal Ground Level comp -lete with internal connection with suitable size of cable ,cable lugs,and cable glands PCC Foundation in Cement Concrete 1:3:6 (20mm Graded Stone Aggregate) and Test-ing after Installation complete all as specified and comprising of the following :– (a) Aluminium bas bar 200 amps - 04 Nos, supported with suitable size of heavy duty porcelin stand lock with suitable size of brass nut, bolts and washer with heat shrinkable PVC sleeving. The bar shall be colour coded (red, yellow and blue) for three phases and black for neutral.b) MCCB 125 amps ,415 volt ,36 KA Breaking capacity 4 pole Electromagnetic release duly connected to Bus Bar As IN COMING - 01 Nos |
| 35 | M&L earthing complete with galvanised steel earth plate 600X600X6 mm thick buried directly in ground (earth pit not les than 2.25 M deep below GL with top edge of plate not less than 1.5 m below GL) connected with GI earth strip of 32X6 mm as earthing leads by means of bolts, nuts, check nuts and washers beside brazing at all joints as shown on drawings and including excavation, earth work. GI pipe light grade 40 mm bore for protection of GI earth strip from earth electrode to and including the earth test point, supplying and laying charcoal dust, common salt PCC (1:2:4) type B1chamber and MS angle iron frame of 40mmx40mm x3 mmand RCC cover 40 mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia TMT bars @ 75 mm C/C both ways with MS handle 12 mm dia, PGI funnel and wire mesh, 20 mm dia GI pipe light grade for watering all as shown in electrical plate No 3 of SSR Part -I and conected to earth test point including testing complete all as secified and directed. Please Enable Macros to View BoQ information |