| 1 | M&L under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 25 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.Note:- Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately. |
| 2 | All as per item No. 1 here-in-before but cross-sectional area 16 sqmm, 4 core complete. |
| 3 | All as per item No. 1 here-in-before but cross-sectional area 10 sqmm, 2 core complete. |
| 4 | M&L for GI pipe 40 mm dia \\"light grade\\" ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings including taking up / down and removing old unserviceable GI pipe complete all as specified and directed . |
| 5 | Excavation in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for Pole, shafts, cesspits, manholes, pier holes, etc and getting out of any type of soil complete all as specified and directed. |
| 6 | All as per Item No: 5 above but depth exceeding beyond 1.5mtr and not exc 3 metre all as specified and as directed |
| 7 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 8 | Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed. |
| 9 | Material and labour for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed. |
| 10 | Material and labour for well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed |
| 11 | M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc including necessary form work, complete all as specified & directed. |
| 12 | M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of pole etc including necessary form work, complete all as specified & directed. |
| 13 | Supply, fixing and erection of steel tubular swaged pole 09 m long, type 410 SP-31, weight not less than 154 kgs, pole should be in one piece only and smooth finishing, ISI marked conforming to IS:2713-1980, complete with all accessories, such as cast iron base plate, finial taper plug, bolts, nuts, screws, washers and drilling of holes for continious GI earth wire as specified including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface including taking down old unserviceable pole complete all as specified and directed.Note:-Excavation and earth work shall be measured and paid separately. |
| 14 | M&L for replacement of GI bracket for fixing of street light fittings bend to shape, made out of 40/50 mm dia GI pipe medium grade suitable for fixing of Light upto 1.2 mtr long fixed with and including two sets of MS clamp made out of Flat iron of size 50x6 mm, fabricated to shape and fixed with nuts, bolts & washers & two coats of aluminum paint over a coat of red oxide primer complete all as specified and directed by Engr-in-charge. |
| 15 | M&L for replacement of wiring with two nos single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm and one single core PVC insulated (unsheathed) multi strand copper conductor FRLS cable of size 1.5 sqmm as in continuous earth wire drawn into steel pole for connection to security lights from junction box fitted on pole complete all as specified and as directed by the Engineer in charge. |
| 16 | M&L for replacement of junction box hot press moulded SMC of inside dimension size 333 x 233 x 120 mm with locking arrangements consisting of necessary suitable arrangements for incoming & out going cables with cable glands & having aluminium bus bar 4 strips of 20x3mm for TPN on necessary epoxy base insulator and fixing of 6 Amp MCB SP, including necessary 25x3mm flat iron clamps with nuts, bolts & washers all as specified and directed. Make- Sintex GSJB3020 |
| 17 | M & L for pole painting 9.0 mtr long with two coat of aluminium paint after preparation of old painting surface by scrappining including marking of black and yellow strip not less than 30 cm width with sythethic enamelled paint from couping to upto height 1.5 mtr of pole alternative way including necessary `MES & Pole number to be wriiten in the circular yello batch on the pole all as specified and directed. |
| 18 | M&L for replacement of Off load change over switch 63 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handel operated complete all as directed by Engr In Charge. Make: Havells cat no IHBFFE0063 or equivalent |
| 19 | M&L for replacement of Off load change over switch 100 amps 415 volts 4 pole 50 Hz in sheet metal enclosure with out side handel operated complete all as directed by Engr In Charge. Make: Havells cat no IHBFFE0100 or equivalent |
| 20 | M&L for replacement and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 16KA,rating 100Amp,complete as per OEM standard design,all as specified and as directed by the Engineer in charge. |
| 21 | M&L for replacement and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 36KA,rating 160Amp,complete as per OEM standard design,all as specified and as directed by the Engineer in charge. |
| 22 | M&L for replacement of Integral LED security light luminaire 60W LED 230 volts made of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, Luminaire efficacy >=125 Lumens per Watt ,Secondary optics for better light distribution, having two nos Potted driver(OEM)(one inbult and one spare potted driver) 4KV internal +10KV SPD, THD<10%, pf>0.95 and taking down old unserviceable light fittings any type/wattage complete all as specified and as directed. Make: HPL cat ref No.HPLLEDSL60CWEGLA or equivalent Philips or wipro |
| 23 | M&L for replacement of Integral LED security light luminaire 90W LED 230 volts made of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, Luminaire efficacy >=125 Lumens per Watt ,Secondary optics for better light distribution, having two nos Potted driver(OEM)(one inbult and one spare potted driver) 4KV internal +10KV SPD, THD<10%, pf>0.95 and taking down old unserviceable light fittings any type/wattage complete all as specified and as directed. Make: HPL cat ref No.HPLLEDSL90CWEGLA or equivalent Philips or wipro |
| 24 | M&L for replacement of Integral LED security light luminaire 120W LED 230 volts made of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, Luminaire efficacy >=125 Lumens per Watt ,Secondary optics for better light distribution, having two nos Potted driver(OEM)(one inbult and one spare potted driver) 4KV internal +10KV SPD, THD<10%, pf>0.95 and taking down old unserviceable light fittings any type/wattage complete all as specified and as directed. Make: Make: HPL cat ref No.HPLLEDSL120CWEGLA or equivalent Philips or wipro |
| 25 | M&L for replacement of Integral LED flood light luminaire 120W LED 230 volts made of pressure die cast aluminium housing powder coated with high power SMD LED’s lens & toughned glass IP-66, Luminaire efficacy >=125 Lumens per Watt ,Secondary optics for better light distribution, having two nos Potted driver(OEM)(one inbult and one spare potted driver) 4KV internal +10KV SPD, THD<10%, pf>0.95 and taking down old unserviceable light fittings any type/wattage complete all as specified and as directed. Make: HPL cat ref No.HPLLEDFL120CWBSHLM or equivalent Philips or wipro |
| 26 | S&F in replacement of Junction feeder Panel alongwith busbar alumium busbar of 3 phase and neutral 400 Amps suitable for XLPE cable 95 Sqmm 3.5 Core to 120 Sqmm 3.5 core in and out, CPRI approved IP-54 duly painted with epoxy based powder coated paint, including base channel, of size 600x500x450 mm suitable for out door type double door locking arrangement comprising of its accessories, cable gland with hinged door, bus chamber with bolted double door etc dust & vermin proof construction attractive powder coated fixed/groutning on PCC foundation 45cm above ground level including all necessary excavation & earth work complete all as specified and directed. |
| 27 | Material and labour for earthing complete with galvanized steel plate electrodes of size 600mm x 600mm x 6mm thick buried dirctly in ground with earth pit not lesss than 2.25m deep below normal ground level with top edge of plate not less than 1.5 m below normal ground level connected to galvanized iron strip of 25 x 4 mm earthing lead by means of nuts bolts check nuts GI washers earth wire protected by GI pipe 32 mm bore, light grade, including concrete pit in PCC (1:3:6) type C1 of size 45x45x45 cm, precast RCC (1:2:4) type B1 as cover of size 40x40x10 cm with one handle for lifting made out of 8 mm dia MS bar, GI funnel wire mesh, 20 mm bore GI pipe, medium grade, for watering, charcoal or coke and salt packed all around in alternate layers necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part-I including testing on completion including demolition to existing one complete all as specifed and directed. (Note :- (i) PCC pit, RCC pit cover, GI earth protection & watering pipe, funnel, earth strip upto 7.5 Mtr etc shall deemed to be included in the unit rate. |
| 28 | Deduction to be made from BOQ for schedule of credit (Sch 'A' Part - II) Amount of ₹ 42013.00 during AOCNote:- Tenderers shall not quote for this Schedule Please Enable Macros to View BoQ information |