| 1 | M&L for complete paint removing from surface of existing Panel box and M & L for two coats of painting with approved colour of synthetic enamelled paint over a coat of red oxide primer for size of Panel boxes from all in & out side incl angle iron frame work including angles canopy and legs etc.Note: Permission to shutdown of electric supply to the panel to be taken from MES before commencement of work. |
| 2 | M&L for finding faults of LT UG cable XLPE of any size and any length by using computerised / primary current injection method / any other method as directed by the GE and locating fault, cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required.Note: Joints shall be supplied and paid for separately. |
| 3 | M&L for cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material and accessaries suitable for 3.5/4 core XLPE armourd aluminium conductor cable of following size after detection of fault location .Make:3 M,Denson or equivalentNote: Earth work and returning filling which require in above job will be measured and paid seperataly. |
| 4 | (a) 25 Sqmm to 50 Sqmm |
| 5 | (b) 70 Sqmm to 120 Sqmm |
| 6 | (c) 150 Sqmm to 240 Sqmm |
| 7 | Excavation in trenches, n. exc 1.5 Mtr wide and n. exc 1.5 Mtr in depth for foundation/laying of cable and getting out in soft/loose soil complete all as specified. |
| 8 | Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick complete all as specified. |
| 9 | Removing of excavated soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point complete all as specified. |
| 10 | Supply spreading in trenches fine dry river sand for cable protection and punning down gently by hand complete all as specified. |
| 11 | M&L for cable protection cover with sub Class`B` bricks old size laid dry, flat perpendicular across the cable in trenches complete all as specified. |
| 12 | Boring of holes under road, pavement, hard standing by trenchless technology using suitable tools and machinery for laying of pipe upto 150mm bore complete all as specified.Note :- GI pipe shall be measured and paid in concern Item |
| 13 | S & F or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 50mm bore complete all as specified. |
| 14 | S & F or laying galvanixed steel tubing light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 100mm bore complete all as specified. |
| 15 | M/L for taking out Unsv U/G cable PVC insulated armoured PVC sheathed Al. Conductor, LT cable of any size complete all as specified. |
| 16 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:- |
| 17 | (a) 185 Sqmm 3.5 core |
| 18 | (b) 150 Sqmm 3.5 core |
| 19 | (c) 120 Sqmm 3.5 core |
| 20 | (d) 95 Sqmm 3.5 core |
| 21 | (e) 70 Sqmm 3.5 core |
| 22 | (f) 50 Sqmm 3.5 core |
| 23 | (g) 25 Sqmm 4 core |
| 24 | (h) 16 Sqmm 4 core |
| 25 | Supply, laying, testing & commissioning LT XLPE insulated armoured (heavy duty) electric cable of single core 120 Sqmm with stranded copper conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole complete all as specified. |
| 26 | S&F in repair on existing location including taking out of existing MCCBs thermal magnetic ,adjustable type of following capacity :- |
| 27 | (a) MCCB 415 volts 400 Amps 04 pole 36 KA |
| 28 | (b) MCCB 415 volts 250 Amps 04 pole 36 KA |
| 29 | (c) MCCB 415 volts 200 Amps 04 pole 36 KA |
| 30 | (d) MCCB 415 volts 160 Amps 04 pole 25 KA |
| 31 | (e) MCCB 415 volts 100 Amps 04 pole 25 KA |
| 32 | (f) MCCB 415 volts 63 Amps 04 pole 25 KA |
| 33 | M& L for Earthing complete with galvanised mild steel plate electrode 600x600x6 mm thick buried directly in ground vertically (earth pit not less than 2.25 m deep below normal ground level) with the top edge of the earth plate electrode at a depth not less than 1.5m below normal ground level and including GI earth strip 32x6 mm bolted (with GI nuts, bolts & check nuts) and riveted to earth plate electrode at one end connected to metallic bodies of HT/LT equipment etc at the other and earth strip encased in and including 40mm bore GI light grade pipe with all fittings from top of earth plate electrode to body of equipment fixed with and including 25x6 mm flat iron clamps bolts, nuts and washers and including providing watering pipe 20mm bore GI Pipe electrode complete all as specified and shown in elctrical plate No 3 of MES SSR Part-I. the scope of work includes necessary excavation and earth work in any type of soil. removal of soil upto 50 metre PCC pit with precast RCC cover, charcoal/salt funnel, CI frame etc complete all as specified. Note:(i) The concrete pit shall be made in PCC 1:2:4 type B-O, using 12.50 mm graded crushed stone aggregate 40mm thick precast cover slab of RCC(1:2:4), type B-1, using 20mm graded crushed stone aggregate with suitable MS handle in lieu of CI cover. Reinforcement in cover shall be of 8mm dia TMT bars @ 150mm c/c both ways.(ii) Item includes the cost of 7.5 metre GI pipe for protection of earth strip. Any variation in length shall be adjusted through deviation order (iii) Item includes cost of 7.5 metre earth lead strip .Any variation in length shall be adjusted through deviation order.(iv) Earth electrode shall be surrounded by adequate quantity of charcoal dust and salt to a packed thinkness of 15 cm on all sides. |
| 34 | M&L for electrical rubber chequred mat, size 2 m x 1 m x 19 mm complete all as specified. |
| 35 | Supply and fixing in replacement of Lithium base Energy efficient integrated Solar street light of 30/32 watt in Aluminium Die casting body / FRP Bpdy , corrosion resistance,integrated PV panel Automatic dusk to input voltage 12.8V with suitable battery ,Driver efficiency .85%,PV module itself will be used to sense the ambient light to switch ON/OFF the Lamp, inbuilt MPPT charge controller, IP65,both PIR and fixed dimming available,4500 lumens (at full brightness) with grater than 150 lumen per watt,5700ANSI, cool white(5500K-6500K),CRI.70,moptical used, Metal core PCB,Low voltage cutoff ,high power LED,wide beam Angle(120 degree) LED Life 50000 hrs, weight less than 15 kg with GReen/Red indicator swith with suitable battery rating 12.8V-BIS standard of complete all as specified.Protections: Short circuit, overload,Reserve polarity and battery protection.Firm should provide vital parametres Test report from NABL accredited lab and should be of made in India with CE & ROHS complaint. |
| 36 | M & L for servicing of existing APFC pane of cap upto 200 KVAR including carrying out minor maintenance/repairs as required to make functional the systems incl providing 03 Nos CT's of suitable rating in existing LT panel alongwith 6 sqmm copper wire to get result of current in existing panel etc complete all as specified. |
| 37 | S&F in repair Capacitors duty contacor as per existing make and type of following capacity:- |
| 38 | (a) 20 KVAR |
| 39 | (b) 10 KVAR |
| 40 | (c) 5 KVAR |
| 41 | (d) 2 KVAR |
| 42 | (e) 1 KVAR |
| 43 | S & F in repair power facor APFC relay 8 stage 415 V AC,3CT confirming to IS 13340 complete all as specified. |
| 44 | M&L for disconnection of LT panel incl LT cables of size upto 240Sqmm X 3.5/4core from existing foundation and reconnection with same panel after taking necessary corrective action to lift the panel height incl excavation and taking down existing cable with loop, providing new AL lugs and cable gland of appropriate size,insulation tape etc to restore electric supply incl necessary iron work to modify height of existing LT panel upto 1.2 Mtrs above existing level incl necessary welding work,nuts & bolts and 2 coat of paint with existing color over one coat of primer and required necessary PCC work complete all as specified. |
| 45 | Supply & fix in replacement 60 watts LED street light fitings new generation energy saving ,environmental friendly ,long life,versatile pressure die cast aluminium with following specification IP66 with 10KV surge protection , PF>0.95, THD < 10%, input voltage 220-240V AC, operating voltage (VAC) 100V -300 V, Lum Flux (+-) 10% , CRI -80 Lum efficienacy (+-) 10% CCT -5700K road way,luminaire with high power LED as light source suitable drivers etc and connecting with 3 x 1.5 sq mm multistranded PVC insulated copper conductor with PVC Conduit 20mm dia from fittings to the jucntion box and fixing to complete all as specified. |
| 46 | Supply and fixing, install, test and commissioning of LT Feeder pillar box outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof IP-54 protection CPRI approved, factory fabricated, cubical panel free standing type, made out of 3.00 mm thick CRCA sheet with locking arragement , factory made powder coated as approved colour, copper bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 600 Amps rating capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 45 cm height from GL with suitable nut, bolts, washers etc, complete all as specified for suitable to accomodate the following items including supply and fix following items by dismantling exisiting unserviceable LT panel complete. |
| 47 | Incoming:-MCCB 4 pole 400 Amp with breaking capacity 35 KA adjustable type with exended terminals -01 Nos. Outgoing:-[a] MCCB 4 pole 200 Amps with breaking capacity 25KA adjustable type with extended terminals- 02 No.[b] MCCB 4 pole 100 Amps with breaking capacity 16 KA adjustable type with extended terminals- 02 No's.[c] MCB TPN 40 Amps,breaking capacity 16 KA -02 Nos(d ) Current Transformers-03 Nos(e) Digital 3 phase energy meter-01(f) LED RYB indiacator lamps-01/SetNote-: The panel must have separate Bus bar chamber, cable chamber and proper spacing must be maintained between each chamber of panel as per IS . |
| 48 | Supply and fixing, install, test and commissioning of LT busbar Feeder pillar box outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15 mm thick CRCA sheet, factory made powder coated as approved colour, Copper bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 600 Amps rating capacity RYBN insulated with sleeved insulation complete, PCC platform made out of 1:2:4 type B1 and pedestal of 45 cm height from GL with suitable nut, bolts, washers etc, complete all as specified for suitable to accomodate the following items including supply and fix following items by dismantling exisiting unserviceable LT panel complete with LT panel made by CPRI approved manufacturer confiring to IS:-8623-1993. Note - The lay out drawing of the panel shall be got approved by the contractor from GE before panel fabrication and shall be fabricated from CPRI approved manufacture. |
| 49 | [a] Incomer: MCCB 4 pole 400 Amps with breaking capacity 30KA adjustable type with extended terminals- 01 No's.[b] Three phase 4 wire copper busbar 600 Amps rating capacity RYBN insulated with sleeved insulation complete.[c] Digital Ammeter with C.T -03 Nos [d] Digital volt Meter-01 [e] Digital 3 phase energy meter-01[f] LED RYB indiacator lamps-01/Set |
| 50 | S&F of two way side outdoor wall lights 6 watt IP 65/66 surge protection 3000 K warm lights space beauty and light with havells outdoor lighting range as per existing lights complete all as specified. |
| 51 | Supply and fixing, install, test and commissioning of LT Feeder pillar box outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof IP-65 protection CPRI approved, factory fabricated, cubical panel free standing type, made out of 3.00 mm thick CRCA sheet with locking arragement , factory made powder coated as approved colour, copper bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 1000 Amps rating capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB , complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 60 cm height from GL with suitable nut, bolts, washers etc, complete all as specified for suitable to accomodate the following items including supply and fix following items by GE. Make of LT Panel as per CA. |
| 52 | Incoming:- (a) ACB 4 Pole, 415 V, Manual Drawout typewith microprocessor release of capacity 800 A -01 Nos Outgoing:- (a) MCCB 250 Amps FP 25 KA -04 Nos (b) MCCB 160 Amps FP 16 KA-02 Nos(c) Copper bus bar 1000 Amp 3 phage and neutral -01 Nos (d) Indicating Lamp set of three - 01 Nos(e) Ammeter Digital type -01 Nos(f) Voltmeter digital type -01 Nos |
| 53 | Taking down and S&F decorative lighting Poles made from CRCA,with decorative side arms,antiquely designed for architectural street lighting applications,suitable for mounting double decorative lights fittings with LED Street light (40W capacity - 02 No.) antique design street light with poles of minimum 3.5mtr ht. with twin arms LED Celesta Luminaires, poles duly powder coated housings made from CRCA / GI Poles diffuser to provide uniform and pleasant light output IP65 Type with complete all as accessories specified. Make: Shakti fixtures cat Part No. SZPSCPD1x40W or equivalent. |
| 54 | M&L for LT cable route indicator made out of PCC(1:2:4) type B-0(12.5mm graded aggregate of size 1000mm (H) x 120mm (W) x 80mm (thick), painted with Specified colur lettering synthetic enamel paint and embedded in PCC block (1:3:6) type C2 (using 40mm grade stone aggregate ) inuding necessary excavation for PCC block, placed complete all as specified. Please Enable Macros to View BoQ information |