| 1 | M&L for replacement of under ground XLPE insulated, screened, PVC bedded galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 1100 volts (earthed) grade cross sectional area 120 sqmm, 3.5 core laid in trenches/ pipes/ ducts/ wall/ boarings with necessary cable lugs and glands, nuts, bolts and washers etc and testing including disconnecting and taking out of existing LT cable of any type and size complete all as specified and directed.Note:- Excavation and earth, sand coushioning and protection for cable work shall be measured and paid separately. |
| 2 | All as per item No. 1 here-in-before but cross-sectional area 95 sqmm, 3.5 core complete. |
| 3 | All as per item No. 1 here-in-before but cross-sectional area 70 sqmm, 3.5 core complete. |
| 4 | All as per item No. 1 here-in-before but cross-sectional area 50 sqmm, 3.5 core complete. |
| 5 | All as per item No. 1 here-in-before but cross-sectional area 35 sqmm, 3.5 core complete. |
| 6 | All as per item No. 1 here-in-before but cross-sectional area 16 sqmm, 4 core complete. |
| 7 | All as per item No. 1 here-in-before but cross-sectional area 16 sqmm, 2 core complete. |
| 8 | M&L for GI pipe 80 mm dia \\"light grade\\" ISI marked, laid in trenches/ on floors/on, pole/road for cable protection including necessary joints / fittings including taking up / down and removing old unserviceable GI pipe complete all as specified and directed . |
| 9 | All as per Srl item No 8 here-in-before but 50 mm dia |
| 10 | Excavation in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for Pole, shafts, cesspits, manholes, pier holes, etc and getting out of any type of soil complete all as specified and directed. |
| 11 | All as per Item No: 10 above but depth exceeding beyond 1.5mtr and not exc 3 metre all as specified and as directed |
| 12 | Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 13 | Returning, Filling in including Spreading, Leveling, Watering and Well Ramming in layers not exc. 25 Cm thick in Soils, complete all as specified and as directed. |
| 14 | Material and labour for sand cushioning with fine dry unwashed sand in trenches for protection of cables complete all as specified and directed. |
| 15 | Material and labour for well burnt bricks,Sub class 'B' bricks, best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed |
| 16 | M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foundation of poles etc including necessary form work, complete all as specified & directed. |
| 17 | M&L for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in stay etc including necessary form work, complete all as specified & directed. |
| 18 | M&L for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping of pole etc including necessary form work, complete all as specified & directed. |
| 19 | Supply, fixing and erection of steel tubular swaged pole 09 m long, type 410 SP-32, weight not less than 154 kgs, pole should be in one piece only and smooth finishing, ISI marked conforming to IS:2713-1980, complete with all accessories, such as cast iron base plate, finial taper plug, bolts, nuts, screws, washers and drilling of holes for continious GI earth wire as specified including applying two coats of aluminium paint over one coat of red oxide zinc chrome primer and embedded portion shall be painted with two coats of black paint after preparation of surface including taking down old unserviceable pole complete all as specified and directed.Note:-Excavation and earth work shall be measured and paid separately. |
| 20 | Detecting the fault of LT 440 volt overhead/ underground system of any feeder/location with necessary safety, testing equipment, tools and plants and rectify the defects on top priority basis/ as and when required including testing on completion, complete all as specified & directed. |
| 21 | M&L for replacement of 1100 volts grade heavy duty cable PVC insulated aliminium conductor served with inner sheathing of PVC sheathed with stranded conductor 10 sqmm twin core cable flat or circular, complete all as specified and directed. |
| 22 | M&L for replacement of Shackle type insulator, porcelain, vitreous white / brown including galvanized mild steel straps (of size 31 mm x 3 mm) washers, insulator bolts ( 12 mm dia) washers and nuts per size of height 75 mm and dia 90 mm for working pressure 1100 Volts all as specified and as directed. |
| 23 | M&L for replacement of Pin type insulator , porcelain, vitreous white / brown including one galvanized mild steel spindle, two galvanized iron washers and one nut (galvanized iron) , for size of 100 mm height, 65 mm dia for 1100 volts grade insulator all as specified and as directed. |
| 24 | M&L for replacement of New Aluminium conductor, steel reinforced, of any size, type, fixed to poles and stretching properly drawn for overhead lines on poles including binding at site to insulator with suitable size of wire including 15mm dia PVC seperater at equal interval including removing old unserviceable ACSR conductor complete all as specified and directed. |
| 25 | M & L for pole painting 9.0 mtr long with two coat of aluminium paint after preparation of old painting surface by scrappining including marking of black and yellow strip not less than 30 cm width with sythethic enamelled paint from couping to upto height 1.5 mtr of pole alternative way including necessary `MES & Pole number to be wriiten in the circular yello batch on the pole all as specified and directed. |
| 26 | M&L for replacement and testing moulded case circuit breaker(MCCB),adjustable Thermal and fixed magnetic type, ,4 Pole,415 volts,50Hz,breaking capacity 16KA,rating 100Amp,complete as per OEM standard design,all as specified and as directed by the Engineer in charge. |
| 27 | All as per item No. 26 here-in-before but rating 160Amp & breaking capacity 36KA. |
| 28 | All as per item No. 26 here-in-before but rating 200Amp & breaking capacity 36KA. |
| 29 | All as per item No. 26 here-in-before but rating 250Amp & breaking capacity 36KA. |
| 30 | M&L for replacement of cross arms, bracings, supports clamps and back plates fabricated from structural steel sections incl. nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface all as specified and as directed. |
| 31 | M&L for replacement of stay assembly galvanised iron complete with accessories stay rod 20 mm dia, 180cm long with two nuts, stay bow 14mm dia and 38cm long with stay plate 300x300x6mm thick mild steel stay thimble and required length including binding to insulator stay bow and stay clamp galvanised iron stay strand wire 7/4mm dia, complete all as specified and shown in EP plate No 1 of SSR part-I, complete all as specified and directed. NOTE :- Excavation, earth work and concrete shall be measured and paid separatly |
| 32 | Material and labour for loop type insulator, vitreous porcelain green, white or brown with overall dimension 65mm x 90mm,clearence of hole 16mm complete all as specified and as directed |
| 33 | M&L in replacement of 1.1 KV LT (Heat shrinkable) cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size up to 70 sq mm to 150 sqmm. |
| 34 | M&L in replacement of 1.1 KV LT (Heat shrinkable) cable jointing kit for 1.1 KV grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size up to 25 sq mm to 50 sqmm. |
| 35 | M&L in replacement of PVC separator four way suitable for LT over head lines all as specified and directed. Please Enable Macros to View BoQ information |
| 36 | M&L in replacement of PVC separator four way suitable for LT over head lines all as specified and directed. Please Enable Macros to View BoQ information |