| 1 | Taking down earthing material any type and size complete all as specified and directed. |
| 2 | Taking down old aluminium /copper strip of any type & size including porcelain insulator complete all as specified and directed. |
| 3 | Taking down old air termination rods copper/aluminium of any type & size complete all as specified and directed. |
| 4 | Taking down old test point terminal box of any type & size complete all as specified and directed. |
| 5 | Taking down old GI pipe of any tyep and size complete all as specified and directed. |
| 6 | Taking down existing unserviceable Distribution boards with MCBs any size and any type complete all as specified and as directed |
| 7 | Taking down existing unserviceable MCCB's/RCBOs any size and any type complete all as specified and as directed |
| 8 | Taking down existing submain wiring of any size or any type complete all as specified and as directed |
| 9 | Taking down existing GI pipe complete all as specified and as directed |
| 10 | S & F sheet metal enclosure MCB DB SPN 4 way with 100 amps rated aluminium bus bar 240 volts double door with locking system complete all as specified and as directed . |
| 11 | S & F sheet metal enclosure MCB DB SPN 8 way with 100 amps rated aluminium bus bar 240 volts double door with locking system complete all as specified and as directed . |
| 12 | S & F sheet metal enclosure MCB DB SPN 12 way with 100 amps rated aluminium bus bar 240 volts double door with locking system complete all as specified and as directed . |
| 13 | S & F of TPN DB 4 way horizontal made out of CRCA sheet housing duly powder coated & confirming to IS specification complete all as specified and as directed. |
| 14 | S & F of TPN DB 8 way vertical load line with incoming as MCCB TP 415 volts AC 3 phase 50 Hz with fixed magnetic setting for current rating of 63 Amps 16 KA ,4P made out of CRCA sheet housing duly powder coated & confirming to IS specification with busbar rating not less than 160 A complete all as specified and as directed . |
| 15 | S & F Single pole and Neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps (AC Box) all as specified and as directed. |
| 16 | S&F MCCB 415V, 16KA, 63 amps 4 Pole thermal magnetic release fixedtype,short circuit and over load protection suitable for DB including all as specified and as directed. |
| 17 | S&F MCCB 415V, 16KA, 100 amps 4 Pole, thermal magnetic release fixedtype,short circuit and over load protection suitable for DB all as specified and as directed. |
| 18 | S&F MCCB 415V, 16KA, 150/125 amps 4 Pole, thermal magnetic release fixedtype,short circuit and over load protection suitable for DB all as specified and as directed |
| 19 | S & F MCB SP 6 to 32 Amps 240 volts C type with rupturing capacity 10 KA all as specified and as directed |
| 20 | S & F MCB SP 40 Amps 240 volts C type with rupturing capacity 10 KA all as specified and as directed |
| 21 | S & F MCB SPN 40 to 63 Amps 240 volts C type with rupturing capacity 10 KA all as specified and as directed |
| 22 | S&F RCBO four pole 30mA capacity 40 Amps 240 volts complete all as specified & directed |
| 23 | S&F MCB TPN 63Amps 'C' series complete all specified and directed |
| 24 | S&F MCB TPN 100Amps 'C' series complete all specified and directed Please Enable Macros to View BoQ information |
| 25 | S&F MCB TPN 100Amps 'C' series complete all specified and directed Please Enable Macros to View BoQ information |