| 1 | M&L for servicing, repair and replacement of unserviceable parts at E/M yard including opening of fan body of any type make & model cleaning, separating serviceable parts for reuse / refix same after repairing and replacing defecive parts witth new one of certain minor spares and consumables like MS screws, 2 way connector, rubber/ reel, insulator,condenser holder, ms nuts bolts, washers, grease is deemed to be included in the quoated rate ) reassembling, greasing complete all as specified and directed for the following:- Note: ( major spare parts required against repaires will be measure & paid seprately under relevent items of sch A) |
| 2 | Ceiling Fan 1200mm Sweep of any make or model |
| 3 | Ceiling Fan 1400mm Sweep of any make or model |
| 4 | Wall / Cabin Fan 400 / 450mm Sweep of any make or model |
| 5 | Exhaust Fan 450mm Sweep of any make or model |
| 6 | Pedestal Fan 400 / 450mm Sweep of any make or model |
| 7 | Air Circulator Fan Heavy duty 450/600mm Sweep of any make or model |
| 8 | M & L for rewinding the fans of any make, any model, from a reputed workshop, removing the burnt winding, cleaning slots, re-winding the motor with super enameled copper wire of size equivalent to the original winding including insulated packing materials, Varnishing, Drying etc with replacement of ball bearing, GM bush, body screws, testing and commissioning on full load for 4 hrs continuous running all as directed for the following:- |
| 9 | Wall / Cabin Fan 400 / 450mm Sweep of any make or model |
| 10 | Exhaust Fan 450mm Sweep of any make or model |
| 11 | Pedestal Fan 400 / 450mm Sweep of any make or model |
| 12 | Air Circulator Fan Heavy duty 600mm Sweep of any make or model |
| 13 | S & F, Condensor / Capacitor, 240V, AC, suitable for fans all as directed for the following:- |
| 14 | 2.5 mfd, Make :- Havells, Tibcon, Epcos |
| 15 | 3.15 mfd, Make :- Havells, Tibcon, Epcos |
| 16 | 4.0 mfd, Make :- Havells, Tibcon, Epcos |
| 17 | S & F Nickel plated mild steel clamps, rubber reel insulator Nuts, Bolts, Washers and split pin suitable for ceiling fans any type, any make, any size complete all as specified and directed |
| 18 | S & F, Down rod, suitably threaded and holed, made out of 15mmdia GI tubes, duly painted, 300mm long, suitable for ceiling fans any type, any make, any size complete all as specified and directed |
| 19 | All as per item No 5 here-in-before but 600mm long |
| 20 | All as per item No 5 here-in-before but 900mm long |
| 21 | S & F, 1100V grade PVC sheathed PVC insulated flexible 2 core cable with multistranded copper conductor of size 1.5Sqmm, ISI Marked complete all as specified and directed |
| 22 | Supply & fixing in repair base plate for wall mounting fan any type/ size as per existing size of fan complete all as specified and directed |
| 23 | S & F in repairs, Wall fan, 450mm sweep, AC,230V incl T/D old u/s one and depositing to MES store complete all as specified and directed. |
| 24 | S & F in reapirs, PVC fresh air fan, 250mm sweep with louvers, AC, 230V incl T/D old u/s one and depositing to MES complete all as specified and directed. |
| 25 | All as per Srl item No 11 here-in-before but 200mm sweep |
| 26 | S & F in reapirs Exhaust fan metal body 450mm with louvers, AC, 230V incl T/D old u/s one and depositing to MES complete all as specified and directed. |
| 27 | All as per Srl item No 13 here-in-before but 300mm sweep |
| 28 | Supply and fixing in replacement of new compressor hermetically sealed type equipped with suitable rated capacity electric motor and over load protection making all existing connection including testing complete all as directed for 1.5 ton Window /Split type Air conditioners complete all as specified and directed |
| 29 | All as per Srl item No 15 above but of capacity 2 ton. |
| 30 | All as per Srl item No 15 above but Invertor type 1.5 Ton. |
| 31 | M&L for Gas refrigerant R12/R22/R410A/R134a in the sealed system of window/Split type AC 1.5/2 Ton capacity after checking leakage / pressure vacumising flushing the sealed unit including replacement of filter drier and capillary tube complete all as specified and directed |
| 32 | Taking down of window/Split AC 1.5/2.0 any type/any model ton capacity and cleaning / servicing of AC, overhauling of blower motor replacement of worn out parts, preparation of body for painting one coat of black paint inner side and one coat synthatic enameled paint on the outer cover of AC and marking of SM/MES No and testing of full load of summer season and reinstallation at site complete all as specified and directed. Note : Worn out parts shall be measured & paid seperately. |
| 33 | S&F in repair Blower motor 1/6 HP with base / rubber bush complete Suitable for split AC of capacity 1.5/2 TR any make / model complete all as specified and directed |
| 34 | All as per Srl item No 20 above but Condensor fan motor Suitable for Split AC/ Window AC double ended of capacity 1.5 / 2 Ton AC complete |
| 35 | All as per Srl item No 20 above but Condensor fan blade metallic. |
| 36 | All as per Srl item No 20 above but Drum type blower fan PVC as per existing. |
| 37 | All as per Srl item No 20 above but Running capacitor 36 mfd. |
| 38 | All as per Srl item No 20 above but Starting capacitor 100 to 120 mfd |
| 39 | All as per Srl item No 20 above but Selector switch. Any make / any model |
| 40 | All as per Srl item No 20 above but Thermostate |
| 41 | All as per Srl item No 20 above but with plastic / juite Air filter. |
| 42 | All as per Srl item No 20 above but cooling coil assembly suitable for any make / any model as per site requirement. |
| 43 | All as per Srl item No 20 above but condensor coil assembly. |
| 44 | All as per Srl item No 20 above but Wiring kit complete. |
| 45 | All as per Srl item No 20 above but Capacitor 6 mfd. |
| 46 | All as per Srl item No 20 above but Blower motor 1/3 HP for indoor unit split type AC suitable for any Make / any model as per site requirement. |
| 47 | All as per Srl item No 20 above but Running capacitor 45 mfd. |
| 48 | All as per Srl item No 20 above but Blower fan 3 Ft long suitable for split AC (as per existing) complete all as specified and directed |
| 49 | Supply and fix in replacement of electronic circuit plate (PCB) with remote control including necessary repairs to electronic circuit operation suitable for 1.5 / 2.0 ton split/window type AC . |
| 50 | Supply and fix in replacement Air break contactor relay 6.2 Amps, 415 Volts AC suitable for split type AC complete all as specified and directed |
| 51 | Labour for shifting of split AC 1.5 , 2 ton capacity one place to another places as required at site and disconnecting of copper tubing, PVC pipe connection and installation of New location indoor/outdoor unit complete with Gas charging tested on full load on summer season complete all as specified and directed |
| 52 | Supply and fixing in replacement of new compressor hermetically sealed type type compressor suitable for 300 to 320 ltrs capacity refrigerator with suitable rated capacity electric motor and shall be equipped with relay / over load protection 230 Volt, 50 Hz, including testing for any make or model complete all as specified and directed |
| 53 | All as Srl item No 39 here-in-before but 165 ltrs to 260 ltrs. |
| 54 | M&L for filling/charging Gas refrigerant R22/R134a/R438A in the sealed system of refrigerator of any make / capacity after checking leakage / pressure vacumising flushing the sealed unit including replacement of filter drier and capillary tube complete all as specified and directed |
| 55 | Supply and fixing starting relay with OLP kit suitable for any make Suitable for any / model refrigerator complete with testing and commissioning complete all as specified and directed |
| 56 | Supply and fix in replacement of thermostat switch suitable for any make/model complete all as specified and directed |
| 57 | Supply and fixing in replacement of condensing coil suitable for any make / model / refrigerator for the following capacity ( As per Sample ) :- (a) 300 / 310 ltr complete all as specified and directed |
| 58 | All as per Srl item No 54 here-in-before but 165 ltrs to 210 ltrs. |
| 59 | S&F in replacement of PVC gaskit magnetic type for suitable for any make / any model / any capacity refrigerator complete all as specified and directed |
| 60 | S&F in replacement of cooling fan motor with metallic blade for any cap / any type complete all as specified and directed |
| 61 | Supply and fixing in replacement of new compressor hermetically sealed type with suitable rated capacity electric motor and shall be equipped with over load and relay, 230Volt, 50 Hz, includind testing single suitable for water cooler 40/80 ltr capacity complete all as specified and directed |
| 62 | All as per Srl item No 48 above but 60/120 ltr capacity. |
| 63 | M&L cleaning of water cooler tank from inner side with soda / Acid and de-scaling of water cooler to remove by brushing and soldering the leaking places and prepare the leak proof and complete all as specified and directed |
| 64 | Dismantling the blower motor of water cooler 1/32 HP capacity, 230 volts, SP and taking out burnt out copper winding wire from motor and M&L for rewinding the electric motor with super enameled copper winding wire of same size and gauge including insulation material, varnish and bush, shaft and refixing the motor complete & testing on full load including replacement of unserviceable spares complete all as specified and directed |
| 65 | All as per Srl item No 51 above but 1/6HP for 150 ltr water cooler / AC |
| 66 | S&F in replacement of starting relay No. 522 / 1622 for water cooler complete all as specified and directed |
| 67 | S&F in replacement of starting capacitor 40-60 mfd 220 Volts complete all as specified and directed |
| 68 | All as per Srl item No 51 above but for capacitor 60-80 mfd 220 Volts. |
| 69 | All as per Srl item No 51 above but for Running capacitor 15 mfd, 415 volts. |
| 70 | All as per Srl item No 51 above but for capacitor 10 mfd, 415 volts . |
| 71 | All as per Srl item No 51 above but for capacitor 36 mfd, 415 volts . |
| 72 | Supply and fixing in replacement of PVC float valve with rod and plastic ball suitable for 1/2\\" bore of water cooler complete all as specified and directed |
| 73 | Supply and fixing in replacement of LDPE 25 mm dia flexible pipe heavy duty with suitable clamp complete all as specified and directed |
| 74 | Supply and fixing PVC pipe flexible type 32 mm dia for waste water draining complete all as specified and directed |
| 75 | Supply and fixing in replacement over load protector (OLP) for water cooler of any capacity complete all as specified and directed |
| 76 | Supply and fixing in replacement self closing push cock 15mm bore chromium plated brass heavy duty long body inner threaded complete all as specified and directed |
| 77 | Supply and fixing in replacement aluminium blade for blower motor of water cooler 80 ltrs to 150 ltrs complete all as specified and directed |
| 78 | Supply and fixing in replacement open type relay : CAJ-2612 |
| 79 | Supply and fixing in replacement thermostat of water cooler of any type make complete all as specified and directed |
| 80 | Supply and fixing in replacement blower motor 1/32 HP 230 volt suitable for water cooler complete with base frame/and rubber bush make AUE/GE for 60 to 150 ltrs complete all as specified and directed |
| 81 | Supply and fix water tank gasket for water cooler 40/80 ltr cap complete all as specified and directed |
| 82 | S&F wiring kit complete for water cooler complete all as specified and directed |
| 83 | Supply & Fixing Voltage Stabilizer 4 KVA with input variation between 170V to 250V with output voltage stabilized at 220 to 240V with accuracy of +/- 2.5% complete all as specified and directed Note:- Taking down old one and depositing to MES complete all as specified and directed. |
| 84 | DESERT COOLER:- Servicing / Disconnection desert cooler fan from desert cooler for repairing including cleaning, greasing,oiling , welding or M'seal at leaking place and refixing back after repair in original position including replacement of unserviceable spares. ( parts to be replaced will be measured and paid separately under elevant items) |
| 85 | S&F in repair rewinding desert cooler fan motor upto 4000cum cap any type/any model/make complete all as specified and directed |
| 86 | Supply and fixing in replacement of capacitor 4 mfd for kit fan / Exhaust fan complete all as specified and directed |
| 87 | Supply and fixing in replacement of PVC water distributer 3 way / 4 way for desert cooler of any size / capacity complete all as specified and directed |
| 88 | Supply and fixing in replacement of PVC elbow suitable for desert cooler of any size / capacity complete all as specified and directed |
| 89 | Supply and fixing in replacement of PVC flexible pipe 15 mm dia suitable for water distribution system of Desert cooler of any size / capacity complete all as specified and directed |
| 90 | Supply and fixing in replacement of Vertical lifting pumps 1/70 HP, 230 Volts single phase complete all as specified and directed |
| 91 | Supply and fixing in replacement of Sumersible pump suitable for desert cooler/ industrial cooler complete upto 4000/6000 cum complete all as specified and directed |
| 92 | Supply and fixing in replacement of wood wool padding of desert cooler of suitable size 4000cum in wire net complete weight not less than 450 gms complete all as specified and directed |
| 93 | Supply and fixing in replacement of wood wool padding of Industrial type cooler of suitable size 6000cum in wire net complete weight not less than 450 gms complete all as specified and directed |
| 94 | Supply and fixing in replacement side shutter (set of three) for desert cooler of as per sample 22 gauge PGI sheets grill type complete all as specified and directed |
| 95 | Supply and fix fan motor copper wounded suitable for desert cooler 230 volts, 50 Hz, single phase AC supply of capacity 4000 Cum complete all as specified and directed |
| 96 | Supply and fix fan motor copper wounded suitable for Industrial desert cooler 230 volts, 50 Hz, single phase AC supply of capacity 6000 Cum complete all as specified and directed |
| 97 | Supply and fix fan motor of Industrial cooler 3 phase, 415 V ,6000 Cum complete all as specified and directed |
| 98 | Supply and fix 3 core 1.5 sqmm copper flexible wire complete all as specified and directed |
| 99 | Supply and fixing in replacement of Mettalic fan blade for desert cooler motor 4000 Cum complete all as specified and directed |
| 100 | Supply and fixing in replacement of Mettalic fan blade for Industrial desert cooler motor 6000 Cum complete all as specified and directed Please Enable Macros to View BoQ information |