| 1 | Taking down shutters of any description exc 1.0 Sqm and nexc 2 sqm, adjusting or cutting required if any and refixing in same opening complete all as specified and as directed. |
| 2 | Demolition of cement concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and as directed. |
| 3 | Dismantling floor, hearth , wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 4 | M & L for Glazed ceramic Coloured Tile of size300x450x7mm/300x600x7 mm thick as in Skirting, Dados, etc., Set and Jointed in Neat Cement Slurry and Pointed in White or Colour Cement to match laid over and including a backing coat of 10mm thick in CM 1:4 screed, complete all as specified and as directed. |
| 5 | M&L for 25 mm thick Cement concrete type B-1, 1:2:4 mix using (20mm graded stone aggregate) over sub base to recd floor tiles complete all as specified and directed. |
| 6 | M&L for Non Skid Ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the tile colour over and including Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM (1:6). complete all as specified and directed. |
| 7 | M&L for non skid ceremic coulred tiles 7 to 8mm thick area of each tile exc 0.18 sqm but n exc 0.38 sqm in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to mortar.Laid over and including15 mm thick cement screed bed in CM 1:6 complete all as specified and as directed. |
| 8 | All as per Item No 7 above here–in–before but on vertical surfaces such as skirtings and risers to steps etc. Over and including10mm thick rendering in CM 1:4 as in backing coat complete all as directed. |
| 9 | M&L preparation of old painted surfaces of wood & wood based of any description over 10 cm in width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed. |
| 10 | Complete removal of existing treatment and applying wall care putty where required to fill up holes to achieve smooth surfaces of wall / ceiling and applying two coats of Oil Bound Distemper with roller of approved shade/tint complete all as specified and as directed. |
| 11 | M&L preparation of old painted surfaces of steel of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint complete all as specified and as directed. |
| 12 | Demolition of cement concrete of any description and in any position not otherwise specially provided for complete all as specified and as directed . |
| 13 | M&L for 25 mm thick Cement concrete type B-1, 1:2:4 using (20mm graded aggregate) complete all as specified and directed. |
| 14 | M&L for polished Vitrified tile ultra charge , 9-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.38 ( 600x600) sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortor 1:6 complete all as specified and as directed . |
| 15 | Ditto all as per item No 14 above but over and including 10mm thick rendering in CM 1:4 as in skirting complete all as specified and as directed . |
| 16 | Dismantling Wall and Ceiling Boards (Fibre ,Pulp,insulation ,etc)or insulation boards /slabs/blankets ,any thickness,including cover fillets complete all as specified and as directed . |
| 17 | M&L for 18/19 MM thick Block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work complete all as specified and as directed . |
| 18 | S&F 0.90 mm thick Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete all as specified and directed. |
| 19 | M&L for 6 mm thick teak wood leaping all around for 19/20 mm shutter including polishing painting fixed with suitable adhesire and, headless screws complete all as specified and as directed. |
| 20 | S&F Hasp and staple, 100mm size, safety type, aluminium anodised brass hinge pin including bolt to hinge plate & fixed with screws, complete all as specified and as directed. |
| 21 | S&F continuous (Piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) 30 mm, complete all as specified and as directed. |
| 22 | Supply and fix 40mm dia, cup board knobs fixed with nuts, screw and washer of brass polished , complete all as specified and as directed. |
| 23 | S&F ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed, complete all as specified and as directed. |
| 24 | S&F for Anodised aluminium snap grid frame work for false ceiling perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to entre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre and Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and as directed. |
| 25 | M&L for non asbestos fibre cement building boards of 4mm thick fixed or laid/ inserted to aluminium snapgrid frame work fixed in jointless finish with jointing compound and jointing tape as per manufacturer instructionscomplete all as specified and as directed. |
| 26 | Dismantling Timber scantlings 40 Sqm cm over in section in any position framed work complete all as specified and directed. |
| 27 | M&L for wrought second class hard wood in scantlings framed and fixed complete all as specified and directed. |
| 28 | Fixing only for wrought second class hard wood in scantlings framed and fixed complete all as specified and directed. |
| 29 | M&L for preparation of wood and wood based material , new or old of any description and girth not otherwise described and treated with creosote oil complete all as specified |
| 30 | M&L for 2nd class hard wood Plain fillets square, rectangular or triangle in section, clean swan secured with nails section area exc 13 Sqm but nexc nexc 25 sqm incl fix with screw complete all as specified and directed. |
| 31 | Demolition of brick work/ solid concrete block work built in Cement mortarcomplete all as specified and as directed . |
| 32 | M&L for precast cement concrete block masonry with solid blocks exc 10 cm in width and settings in CM 1:6 type C1 1:3:6 (20mm graded aggregate) complete all as specified and as directed. |
| 33 | M&L for PCC 1:3:6 type C-2 (using 20 mm graded stone aggregate ), 75 mm thick as in plinth protection finished even and smooth without using extra cement layed in bays not exc.2.00 sqm complete all as specified and as directed . |
| 34 | M&L for rendering 15m thick on fair faces of brick or concrete work in CM 1:4 finished even and smooth without using extra cement complete all as specified and as directed . |
| 35 | M&L for 10 mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra complete all as specified and as directed . |
| 36 | M& L for preparing newly plastered surfaces of wall and applying Two or more coats (over and including 1 mm thick wall care putty ) of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed. |
| 37 | M & L for preparing newly plastere surfaces of wall and applying two coats of oil bound distemper with roller over and including one coat of primer complete all as specified and directed. |
| 38 | M&L for preparation of surfaces and applying putty of 1 mm thickness over plastered surface to prepare the surface even and smooth complete all as specified and directed. |
| 39 | Taking down chowkhat with shutter (without taking off shutter from the frame) area exc 1.5 sqm but n.exc 4 sqm each complete all as specified and directed. |
| 40 | Taking down chowkhat with shutter (without taking off shutter from the frame) area n exc 1.5 sqm each complete all as specified and directed. |
| 41 | M&L for 2nd class hard wood plain solid straight chowkats and frames wrought framed rebated on the solid ,rounded or chamfered ,put together with glue pinned at joints , supplied and fixed complete all as specified and as directed . |
| 42 | S&F for 4 leversBrass Mortice lock,vertical type,100mm length complete all as specified and as directed .. |
| 43 | S&F powder coated (min powder coating 50 micron) aluminium frame for doors, windows , ventilators plain or sliding type with one or more rebates including joining cleat for fixing etc complete all as specified and as directed |
| 44 | S&F for powder coated(powder coating min 50 micron) window and ventilator shutters side hung/sliding type without sash , aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150 mm long(1 no) hinges type B-21 100 mm long (2 no) suitable handle (1 no ) complete as specified |
| 45 | S&F three track sliding powder coated(powder coating min 50 micron) window and ventilator shutters side hung/sliding type without sash , aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, rubber neoprene packing , anodised aluminium snap beading screws ,anodised aluminium fittings such as peg stays 150 mm long(1 no) hinges type B-21 100 mm long (2 no) suitable handle (1 no ) complete all as specified and as directed . |
| 46 | S&F in repair Aluminium extruded section door closer hydraulially regulated, designation No 3, universal type suitable for door shutter of 851 to 1000mm width and of weight of between 61 to 80 kg and fixed complete all as specified and as directed . |
| 47 | Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement complete all as specified and as directed . |
| 48 | S&F for stainless steel double cylinder floor spring for wood/aluminium door with weight Upto 120 kg complete all as specified and as directed . |
| 49 | S&F for stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and as directed. |
| 50 | M&L for 5.5 mm thick toughened glass and glazing fixed to aluminium frame area not exc 0.50 sqm complete all as specified and as directed. |
| 51 | S&F in repairs 20mm dia (curtain rod) Harrison rails, aluminium anodised alloy with fixing brackets, stops, rollers etc complete all as specified and as directed . |
| 52 | S&F for brackets decorative (Lattoo) for 20mm dia curtain rods complete all as specified and as directed . |
| 53 | M&L for preparation of new steel surfaces of any description , over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat red oxide primer complete all as specified and as directed . |
| 54 | M&L for Black Granite slab 20 mm thick rubbed and polished machine cut, set in cement mortar jointed with white cement complete including bedding layer 15mm thick in cement mortar 1:6 over cooking platform & making hole for gas pipe etc through precast RCC slab & granite stone etc incl rounding of exposed edges, complete all as specified.Note:- Colour of Granite approved by the Garrison Engineer. |
| 55 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred/stopped ends etc complete all as specified and as directed . |
| 56 | M & L for 40 mm thick cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in floors finished, surface even and smooth without using extra cement, complete all as specified and directed. |
| 57 | S&F 2nd class Soft Wood boarding 20mm thick fixed with nails in eaves board plained one side with butt joint complete all as specified and directed. |
| 58 | M&L for complete removal of existing wall treatment surface and applying two finishing coat of acrylic emulsion paint , anti fungal resistanc , dirt resistance exterior paint of required shade including primer coat on old surfaces complete all as specified and directed. |
| 59 | M&L for 75 mm PCC(1:4:8) type D2 using 40mm graded stone aggregate as in sub base of floor and filling complete all as specified and as directed. |
| 60 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard dense soil complete all as specified and directed. |
| 61 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 62 | Returning, filling in including spreading, levelling, watering and well ramming in layers n.exc.25 cm thick complete all as specified and directed. |
| 63 | M&L for ard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick watered and well rammed to a true surface complete all as specified and directed. |
| 64 | M & L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed. |
| 65 | M & L for Plain Cement concrete (1:4:8) Type D2 (using 40 mm graded stone aggregated) as in foundations, filling and mass concrete complete all as specified and directed. |
| 66 | M&L for Precast cement concrete block masonry with solid block exc 10 Cm in width with PCC, type C1 1:3:6 mix using 20mm graded stone aggregate) and setting in CM 1:6 complete all as specified and directed. |
| 67 | M&L for rendering 15mm thick on fair faces of lathing wall in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed. |
| 68 | M&L for rendering 15m thick on fair faces of lathing wall in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed. |
| 69 | Supply only Integral waterproofing compound complete all as specified and directed. |
| 70 | M&L for preparation of newly plastered or unplastered wall surface and applying two finishing coats of acrylic emulsion paint , anti fungal resistanc, dirt resistance exterior paint of required shade including primer coat on new surfaces complete all as specified and directed. |
| 71 | S&F floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor, overall length of cover plate 140mm complete all as specified and directed. |
| 72 | M&L for 5.5mm thick sheet glass ordinary quality and glazing with wooden beading in square n exc 0.5 sqm in each pan complete all as specified and directed.. |
| 73 | S&F pre-painted Galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick as in roof covering including fixing with self driving machine made screws with washers and fitting of same manufacture of approved profile, shape and colour complete all as specified and directed |
| 74 | S&F pre-painted Galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick as in roof covering or in eve board including fixing with self driving machine made screws with washers and fitting of same manufacture of approved profile, shape and colour complete all as specified and directed |
| 75 | M&L for framed work like grills grating, etc with ends of bars shouldered and/ or riveted or to x spikes, framed guard bars berred iron doors, ladders framed balusters work ways railing, frame work for water tanks and similar work conforming to F.e 290 Gde-E-165 complete all as specified and directed. |
| 76 | M&L for providing 100 mm thick cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) as in hard standing Complete all as specified and directed. |
| 77 | S&F for PVC (SWR) pipes (half round of 150 mm with rounded edges) as eaves gutters incluing fixing asscessories such as clip/cleats/rubber ring joints with regular interval of 2 mtr, single socketed complete all as specified and directed. |
| 78 | S&F for 150 mm PVC (SWR) pipes single socketed in any length with rubber ring joints fix in eaves gutter as vertical complete all as specified and directed. |
| 79 | M & L for PCC 1:3:6 mix, type C2 (40 mm graded stone aggregate) as in surface channels and drains complete all as specified & directed. |
| 80 | S&F Stack clamps of size 50mm made out of 5mm flat iron and 16mm dia round iron stays ,incl bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed. |
| 81 | M&L for Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed. |
| 82 | M&L for chequered cement concrete tiles 30cm x 30cm x 25mm thick, set, jointed and pointed in neat cement slurry with gray cement and pigment in floors over and including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 83 | M&L for PCC type B0 1:2:4 (12mm aggregate) to 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed. |
| 84 | M&L for vitrified ceramic tiles (Paving dark shed, 10 mm thick(square /rectangular), polished, area of each tile n exc 0.36 sqm in floor etc , laid over and including 15 mm thick screed bed cement mortor1:6 ,set and jointed in neat cement slurry and pointed in white/coloured cement to match complete all as specified and directed. |
| 85 | M & L for prepration of new treated steel surface of any description exceeding 10cm width or girth and applying one coat of synthetic enamelled paint ver roof sheet bldg ht 6 to 9 mtr complete all as specified and directed. |
| 86 | M&L for polished Vitrified tile ultra charge , 9-10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 ( 600x600) sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed in cement mortor 1:6 complete all as specified & directed. |
| 87 | Ditto all as per item No 86 above but over and including 10mm thick rendering in CM 1:4 as in skirting complete all as specified & directed. |
| 88 | Demolition cement concrete in roof and above groung level exc 15 cm thickness all as specified and directed. |
| 89 | M&L for roof treatment as per the description below:-a) Plain cement concrete average 50 mm thick 1:2:4 type B0 (using 12.5 mm graded stone aggrigate )for levelling course for providing slope in the roof @ 1:40 gradientb) Apply bituminous primer @ 0.3 ltr/Sqm (conforming to IS-3384) on prepared surfaces. After drying of primer apply a coat of hot blown 85/25 grade bitumen conforming to (IS-702 @ 1.20 kg/Sqm of prepared surfaces.c) Laying APP (Atactic Polypropylene) modified five layered membrane 3 mm thick and weighing not less than 4 Kg/Sqm with centre core 160 GSM/ Sqm ; core reinforced and laid with 75 mm side overlap and 150 mm end lap. The membrane shall be laid with LPG torch application and overlaps sealed and finished neatly as per the manufacturer specification And apply two coat of silver aluminum paint . |
| 90 | Material and labour for preparation of new plastered surfaces as of walls and applying Two coats of weather proofing exterior acrylic emulsion paint of DULUXWeather shield Max or APEX ULTIMA from Asian paint over one coat of primer from the same manufacturer complete all as specified and directed. |
| 91 | Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, PVC conduit on wall/ceiling and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point controlled by one switch complete all as specified and directed. |
| 92 | Description all as per Srl item No 91 here in before but for socket outlet point 5 Amp on same board complete all as specified and directed |
| 93 | Description all as per Srl item No. 91 here in before but for socket outlet point 5 Amp on Independent board complete all as specified and directed |
| 94 | Description all as per serial item No 91 above but with 4 sqmm cable for 3 pin 15 Amps switch socket outlet (Power point) complete all as specified and directed |
| 95 | Description all as per Srl item No.2 here in before but for socket outlet point 5 Amp on same board complete all as specified and directed. |
| 96 | Supply and fixing modular switch 1 way 6 A with cover plate and frame 230/250 volt , AC supply, ISI Marked, with white cover plate with frame complete all as specified and directed. |
| 97 | Supply and fixing modular sockets with cover plate and frame 6A 2/3 pin combined 2 module 230/250 Volts, 50 Hz , AC supply, ISI Marked, with cover plate complete all as specified and directed. |
| 98 | Supply and fixing modular switch 1 way 16 A with cover plate and frame230/250 volt , AC supply, ISI Marked, with white cover plate with frame complete all as specified and directed. |
| 99 | Supply and fixing modular sockets 6A/16A 2/3 pin combined 2 module with cover plate and frame 230/250 Volts, 50 Hz , AC supply, ISI Marked, with white cover plate with frame complete all as specified and directed. |
| 100 | Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and directed |
| 101 | Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 102 | Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 103 | Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed |
| 104 | Supply and fix Flexible LED strips complete all as specified and directed. |
| 105 | Supply and fix in repair MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking down complete all as specified and directed. |
| 106 | Supply and fix MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed |
| 107 | Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB's. complete all as specified and directed |
| 108 | M & L Sub main wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit on wall/ceiling in PVC conduit, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion including taking down old wiring etc complete all as directed. Note: (i) Two runs of 4 sqmm and one run of 6 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Cutting of chases in the wall of appropriate size shall be carried out with electric cutter machine . (iii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted complete all as specified and directed |
| 109 | Supply and fix in repairs MCB Distribution board , 240 volts single pole and neutral ,double door, sheet steel, enclosure powder coated with 200 Amps rated busbar with neutral link, 8 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection complete all as specified and directed. |
| 110 | M & L Sub main wiring with two run single core 4 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia PVC conduit on wall/ceiling in PVC conduit, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of 4 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion including taking down old wiring etc complete all as directed. Note: (i) Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit shall be measured as one RM. (ii) Cutting of chases in the wall of appropriate size shall be carried out with electric cutter machine . (iii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted complete all as specified and directed. |
| 111 | Supply and fixing LED batten fittings 1x 20 Watt complete including LED light driver, holder, LED lamp and connection up to ceiling rose with three core wire fixed to wall with 2 nos PVC block of suitable size including taking down old unserviceable one complete all as specified and directed. |
| 112 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core Iincluding laying in trench or fixed on wall through clamps complete all as specified and directed. |
| 113 | Excavation in trenches not exc 1.5 m wde and 1.5 m deep for taking out/laying of UG cable/GI pipe of any dismeter in soft/loose soil and getting out complete all as specified and directed |
| 114 | Returning and filling including spreadking levelling watering and well ramming in layers not exc 25 cm thick soft/loose soil ccomplete all as specified and directed. |
| 115 | Removing excavated material at a distance n exc 50m and deposited where directed at a level not exc 1.5 above the starting point for soft/lose soil complete all as specified and directed |
| 116 | M & L for sand filing in trenches for providing sand cushion for protection of UG cable complete all as specified and directed. Note :- Thickness of sand shall be measured oftter punning. |
| 117 | Supply and laying of sub class B bricks locally available alying perpendicular of UG cable complete all as specified and directed. Please Enable Macros to View BoQ information |