| 1 | NOTE: 1. The bidders/ contractors are advised to read tender documents and all corrigendum/ amendments and General conditions of contracts before entry/ quoting the rates. |
| 2 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft loose Soil. |
| 3 | M&L PCC 1:3:6 Type C2 using 40mm grade stone aggregate as in foundation concrete etc complete all as specified and directed. |
| 4 | M&L for use and waste of steel Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter to rough/ finished surface |
| 5 | M & L for use and waste of steel form work to sides of beam / lintel beam and similar structure for flat, rough finished, surfaces all as specified and as directed by Engineer-in-Charge. |
| 6 | M&L for use and waste of steel Formwork to sides of Column square or rectangular in plan for rough finished surface of concrete and the like upto a height of 6.00m from ground level complete all as specified and directed |
| 7 | M&L TMT bars 10mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed. |
| 8 | M&L TMT bars 6mm to 8mm dia and over, cut to length, bent to shape required, incl cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips etc complete all as specified and directed. |
| 9 | All as per item No 7 herein above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders etc complete all as specified and directed. |
| 10 | M&L RCC 1:1.50:3 using 20mm graded aggregate as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed |
| 11 | M&L RCC 1:1.50:3 mix using 20mm graded aggregate columns upto a height of 6.00m from ground level complete all as specified and directed |
| 12 | M&L for 1:1.50:3 mix concrete (using 20mm graded stone aggregate) as in lintel/tie beam/roof beam complete all as specified and as directed. |
| 13 | M&L for Pre-cast cement concrete block masonry Type C1 (1:3:6) 20mm aggregate with solid blocks, exc. 10 cm in width and setting in mortar (1:6), complete |
| 14 | M&L Providing precast cement concrete in PCC 1:3:6 Type C0 using 12.50mm graded aggregate as in louvres and jallies, 40mm thick (measured solid), including all mouldings setting in CM 1:6 complete |
| 15 | M&L rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement. |
| 16 | M&L rendering 15 mm thick other than fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement. |
| 17 | M&L for preparation of newly plastered surfaces of wall and Material & Labour for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces. |
| 18 | S&F 50 mm dia GI tubing, medium grade with all fitting and fixed to walls or laid in floors complete all as directed. |
| 19 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm all as directed. |
| 20 | Removing excavated material n, exc 50m and depositing where directed at a level n exc 1.5m from the base. |
| 21 | Dismantling of posts or struts(wood, steel or RCC) any section embadded in concrete, including taking out embedded portion and making good disturbed ground all as specified and directed. |
| 22 | Dismantling of fencing wire mesh of any type complete all as specified and directed. |
| 23 | Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in soft loose soil or all as specified |
| 24 | M&L for thick hardcore with broken stone of gauge n.exc. 63mm, deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rammed to a true surface. |
| 25 | M & L for cement concrete 75mm thick 1:3:6 (40mm graded aggregate) Type C2 as in sub base all as specified and directed by Engr-in-Charge |
| 26 | M&L Spreading and levelling of Sand/ grit cushioning watering and ramming for interlocking tiles. Note: punned thickness shall be measured for payment |
| 27 | M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment (glossy finish) any shape & size conforming to IS 15658-2006 of 60 mm thickness, M-35 grade etc complete all as specified and as directed. |
| 28 | M&L for Providing precast cement concrete 1:2:4 Type B1 20 mm graded stone aggregate in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings, kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling) corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match Please Enable Macros to View BoQ information |