| 1 | Supply and fix in replacement straight through heat shrinkable cable joint kit including all material and accessories suitable for 3 core 95 sqmm XLPE armoured aluminium conductor cable of 11000 Volt (Earthed) grade all as per manufactuer recommendation complete all as specified and directed by Engr-in-charges. |
| 2 | Supply and fix in replacement straight through heat shrinkable cable joint kit including all material and accessories suitable for 3 core 120 Sqmm to 185 Sqmm XLPE armoured aluminium conductor cable of 11000 Volt (Earthed) grade all as per manufactuer recommendation complete all as specified and directed by Engr-in-charges. |
| 3 | Supply and fix in replacement outdoor type heat shrinkable end termination cable joint kit including all material and accessories suitable for 3 core 95 sqmm XLPE armoured aluminium conductor cable of 11000 Volt (Earthed) grade all as per manufactuer recommendation complete all as specified and directed by Engr-in-charges. |
| 4 | Supply and fix in replacement outdoor type heat shrinkable end termination cable joint kit including all material and accessories suitable for size 120 Sqmm to 185 Sqmm XLPE armoured aluminium conductor cable of 11000 Volt (Earthed) grade all as per manufactuer recommendation complete all as specified and directed by Engr-in-charges. |
| 5 | Supply and fix in replacement Indoor type heat shrinkable end termination cable joint kit including all material and accessories suitable for 3 core 95 sqmm XLPE armoured aluminium conductor cable of 11000 Volt (Earthed) grade all as per manufactuer recommendation complete all as specified and directed by Engr-in-charges. |
| 6 | Supply and fix in replacement Indoor type heat shrinkable end termination cable joint kit including all material and accessories suitable for size 120 Sqmm to 185 Sqmm XLPE armoured aluminium conductor cable of 11000 Volt (Earthed) grade all as per manufactuer recommendation complete all as specified and directed by Engr-in-charges. |
| 7 | Supply and fix in replacement cable jointing kit for 33 KV grade cable for Indoor and termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 185 Sqmm to 240 Sqmm all as per manufactuer recommendation complete all as specified and directed by Engr-in-charge. |
| 8 | Supply and fix in replacement cable jointing kit for 33 KV grade out door end termination heat shrink type, complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 185 Sqmm to 240 Sqmm all as per manufactuer recommendation complete all as specified and directed by Engr-in-Charge. |
| 9 | Taking out old unserviceable HT cable and Supplying, laying, jointing, testing and commissioning of XLPE insulated PVC outer seathed and (earthed) PVC inner sheath, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminum conductors, 11 KV(E) grade and conforming to IS : 7098 and, of size 95 sqmm, 3 core, laid in trenches / ducts / encased in GI pipe / fixed to pole, complete all as specified and directed by Engr-in-charges. Note : Earth work, protection pipe and Cable Joints,Sand cushioing,cable cover etc shall be measured and paid separately. |
| 10 | Supply and fixing in replacement of GI Pipe light grade 100 mm dia with necessary accessories/ fittings bracing with pole/wall by FI clamps made with 32x6mm for cable protections/pole for crossing of culverts/nallah/road and complete all as specified and directed by Engr-in-charges. |
| 11 | Supply and fixing in replacement of GI Pipe light grade 80 mm dia with necessary accessories/ fittings bracing with pole/wall by FI clamps made with 32x6mm for cable protections/pole for crossing of culverts/nallah/road and complete all as specified and directed by Engr-in-charges. |
| 12 | Excavating in trenches n.exc 1.5 m width and n.exc 1.5m in depth for taking out cable and cable cover and getting out in any type of soil complete all as specified and directed by Engr-in-charges. |
| 13 | All as per ser No-12 above but depth exc 1.5 mtr but not exc 3.00 mtr complete all as specified and directed by Engineer-in-Charge. |
| 14 | Returning, filling in, including spreading levelling, watering and well ramming in layers n.exc 25 Cm in soil complete all as specified and directed by Engineer-in-Charge. |
| 15 | Removing excavated materials n.exc 50 mtr depositing where directed at a level n.exc 1.5 m above the starting point and depositing where directed at a level not exceeding 1.5 mtrs above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 16 | M&L for tibba sand filling in trenches dry and and clean sand unwashed including punning around cable for protection of under ground cable complete all as specified and directed by Engr-in-charges. Note :- Only punned thickness will be measured for payment purpose. |
| 17 | Supply and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx180mmx40mm laid perpendicular to cable length in trench air gap should not more than 5mm to each other after sand cushioning to cable and complete all as specified and directed by Engr-in-charges. |
| 18 | M&L for Cutting the road / hard standings and excavating in trenches not exceding 0.40 mtr wide and not exc 0.80 mtr deep across the road for laying cable including making good the excavated portion by means of PCC 1:2:4, type B1 using 20mm graded stone aggregate complete and matching with the surroundings complete all as specified and directed by Engr-in-charges. |
| 19 | Boring under road and foot path for inserting 80/100 mm bore GI tubing for drawing UG cable, complete all as specified and directed by Engr-in-charges. NOTE- GI Pipe to be paid in separate items . |
| 20 | M&L and fixing in true Vertical position prestressed concrete pole 11.00 Mtr long of size 152mm x 152mm at top and 152 mm x 260mm at bottom of class-9 confirming to relevent IS-1678-1998 code and dismantling and removing the old unsv PCC pole and complete all as specified and directed by Engr-in-charges. NOTE - Excavation and Earth work and PCC in foundation shall be measured and paid seprately. |
| 21 | Material and labour plain cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregate as in base of the pole or in any situation complete all as specified and directed by Engr-in-charges. |
| 22 | Material and labour plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of the pole or in any situation complete all as specified and directed by Engr-in-charges. Please Enable Macros to View BoQ information |
| 23 | Material and labour plain cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate as in coping of the pole or in any situation complete all as specified and directed by Engr-in-charges. Please Enable Macros to View BoQ information |