| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. (DSR 2.8.1) |
| 2 | Centering and shuttering including strutting, propping etc. and removal of form for : Foundation, footing bases of columns.(As per DSR no. 5.9.1) |
| 3 | Centring and shuttering including strutting, propping etc. and removal of form for: Columns, Pillars, Piers, Abutments, Posts and Struts. DSR 5.9.6 |
| 4 | Centering and shuttering including strutting, propping etc. and removal of form for : Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.(DSR 5.9.2) |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for: Shelves Lintels, beams, plinth beams, girders, bressumers and cantilevers( DSR 5.9.5) |
| 6 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) (DSR 4.1.8) |
| 7 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. .All works up to plinth level :Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.33.1.1 |
| 8 | Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability and workability including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works above plinth level upto floor V level: Concrete of M25 grade with minimum cement content of 330 kg /cum DSR 5.33.2.1 |
| 9 | Add for using extra cement in the items of design mix over and above the specified cement content therein.(DSR 5.35) |
| 10 | Reinforcement for RCC work including straightening, cutting, bending, placing in position complete. - Upto plinth level Thermo-Mechanically Treated bars. (DSR 5.22A.6) |
| 11 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand) (6.4.1) |
| 12 | Providing and laying 15mm cement plaster of mix. 1:4 (:1 cement : 4 course sand) Complete in all respect to the entire satisfaction of the Engineer-In-Charge. (DSR 13.5.1) |
| 13 | Providing and applying white cement putty of average thickness 1mm of approved brand and manufacture, over the plstered wall surface to prepare the surface even and smooth (birla/J.K etc) complete to the entire satisfactionof the Engineer-in-charge. (DSR 13.80) |
| 14 | Pointing on brick work or brick flooring with cement mortar 1:3 (: 1 cement : 3 fine sand) (Flush/Ruled/Stuck or weathered pointing (DSR 13.31.1) |
| 15 | Finishing walls with Acrylic Smooth exterior paint of required shade :- New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). (DSR 13.46.1) |
| 16 | Steel work welded in built up section / framed work including cutting, hoisting, fixing in position and providing and laying two coat of 1st quality synthetic enamel paint over one coat of approved steel primer using structural steel etc. as required. In grating, frames, guard bar, ladder, railings, complete in all respect and to the entire satisfaction of the Engineer-in-charge. (N.S) Please Enable Macros to View BoQ information |