| 1 | Less credit for existing pumping machinery, dismantled from site, considering residual/scrap value as per actual condition, complete in all respects.(1 No. Pumping Set 2250 LPM 10 BHP)(1 No. Pumping Set 4500 LPM 20 BHP)(1 No. Pumping Set 13500 LPM 60 BHP). |
| 2 | Providing and installing centrifugal mono block pump set suitable for storm water / rain water dewatering, having required discharge of against total required head in metres, complete with Degines BHP, 415 Volts, 3 Phase, 50 Hz squirrel cage induction motor, directly coupled, running at suitable RPM, complete in all respects including cast iron pump casing, CI / bronze semi-open impeller, stainless steel shaft, mechanical seal / gland packing, suitable for handling muddy rain water with suspended solids, including suction pipe with strainer, delivery pipe with non-return valve, with thermal overload protection, necessary foundation bolts, vibration pads, electrical connections, testing and commissioning at site, as per directions of Engineer-inCharge. 13700 LPM 65.00 BHP |
| 3 | Providing and installing centrifugal mono block pump set suitable for storm water / rain water dewatering, having required discharge of against total required head in metres, complete with Degines BHP, 415 Volts, 3 Phase, 50 Hz squirrel cage induction motor, directly coupled, running at suitable RPM, complete in all respects including cast iron pump casing, CI / bronze semi-open impeller, stainless steel shaft, mechanical seal / gland packing, suitable for handling muddy rain water with suspended solids, including suction pipe with strainer, delivery pipe with non-return valve, with thermal overload protection, necessary foundation bolts, vibration pads, electrical connections, testing and commissioning at site, as per directions of Engineer-inCharge. 5600 LPM 25 BHp 12.00 Mtr Head |
| 4 | Providing and installing centrifugal mono block pump set suitable for storm water / rain water dewatering, having required discharge of against total required head in metres, complete with Degines BHP, 415 Volts, 3 Phase, 50 Hz squirrel cage induction motor, directly coupled, running at suitable RPM, complete in all respects including cast iron pump casing, CI / bronze semi-open impeller, stainless steel shaft, mechanical seal / gland packing, suitable for handling muddy rain water with suspended solids, including suction pipe with strainer, delivery pipe with non-return valve, with thermal overload protection, necessary foundation bolts, vibration pads, electrical connections, testing and commissioning at site, as per directions of Engineer-inCharge. 4500 LPM 12.00 Mtr Head 20 BHP |
| 5 | Providing and installing centrifugal mono block pump set suitable for storm water / rain water dewatering, having required discharge of against total required head in metres, complete with Degines BHP, 415 Volts, 3 Phase, 50 Hz squirrel cage induction motor, directly coupled, running at suitable RPM, complete in all respects including cast iron pump casing, CI / bronze semi-open impeller, stainless steel shaft, mechanical seal / gland packing, suitable for handling muddy rain water with suspended solids, including suction pipe with strainer, delivery pipe with non-return valve, with thermal overload protection, necessary foundation bolts, vibration pads, electrical connections, testing and commissioning at site, as per directions of Engineer-in Charge. 6750 LPM 12 mtr head 30.00 BHP |
| 6 | Providing, erecting, installing, testing and commissioning of factory-assembled electrical control panel (DOL / Star-Delta) suitable for operation of required HP, 415 Volts ±10%, 3-phase, 50 Hz squirrel-cage induction motor, complete with MCCB of adequate breaking capacity, copper bus bars, magnetic contactors, thermal overload relay (OLR), electronic single-phasing and phase-reversal preventer, under-voltage and over-voltage protection, dry-running protection through current sensing / water level relay, automatic reset / manual reset arrangement, ammeter and voltmeter with selector switches, R-Y-B LED indication lamps, start/stop push buttons, internal wiring with FRLS copper conductors, proper ferruling, brass cable glands, double earthing terminals, panel enclosure of CRCA sheet steel with IP-54 / IP-55 protection, including all accessories, testing, trial run and commissioning at site, complete in all respects as per relevant IS/IEC standards and directions of Engineer-inCharge. 4500 LPM 12.00 Mtr Head 20 BHP |
| 7 | Providing, erecting, installing, testing and commissioning of factory-assembled electrical control panel (DOL / Star-Delta) suitable for operation of required HP, 415 Volts ±10%, 3-phase, 50 Hz squirrel-cage induction motor, complete with MCCB of adequate breaking capacity, copper bus bars, magnetic contactors, thermal overload relay (OLR), electronic single-phasing and phase-reversal preventer, under-voltage and over-voltage protection, dry-running protection through current sensing / water level relay, automatic reset / manual reset arrangement, ammeter and voltmeter with selector switches, R-Y-B LED indication lamps, start/stop push buttons, internal wiring with FRLS copper conductors, proper ferruling, brass cable glands, double earthing terminals, panel enclosure of CRCA sheet steel with IP-54 / IP-55 protection, including all accessories, testing, trial run and commissioning at site, complete in all respects as per relevant IS/IEC standards and directions of Engineer-inCharge. 5200 LPM - 50 BHP |
| 8 | Providing, erecting, installing, testing and commissioning of factory-assembled electrical control panel (DOL / Star-Delta) suitable for operation of required HP, 415 Volts ±10%, 3-phase, 50 Hz squirrel-cage induction motor, complete with MCCB of adequate breaking capacity, copper bus bars, magnetic contactors, thermal overload relay (OLR), electronic single-phasing and phase-reversal preventer, under-voltage and over-voltage protection, dry-running protection through current sensing / water level relay, automatic reset / manual reset arrangement, ammeter and voltmeter with selector switches, R-Y-B LED indication lamps, start/stop push buttons, internal wiring with FRLS copper conductors, proper ferruling, brass cable glands, double earthing terminals, panel enclosure of CRCA sheet steel with IP-54 / IP-55 protection, including all accessories, testing, trial run and commissioning at site, complete in all respects as per relevant IS/IEC standards and directions of Engineer-inCharge.13700 LPM 65.00 BHP |
| 9 | Providing, erecting, installing, testing and commissioning of factory-assembled electrical control panel (DOL / Star-Delta) suitable for operation of required HP, 415 Volts ±10%, 3-phase, 50 Hz squirrel-cage induction motor, complete with MCCB of adequate breaking capacity, copper bus bars, magnetic contactors, thermal overload relay (OLR), electronic single-phasing and phase-reversal preventer, under-voltage and over-voltage protection, dry-running protection through current sensing / water level relay, automatic reset / manual reset arrangement, ammeter and voltmeter with selector switches, R-Y-B LED indication lamps, start/stop push buttons, internal wiring with FRLS copper conductors, proper ferruling, brass cable glands, double earthing terminals, panel enclosure of CRCA sheet steel with IP-54 / IP-55 protection, including all accessories, testing, trial run and commissioning at site, complete in all respects as per relevant IS/IEC standards and directions of Engineer-inCharge.21900 LPM 100 BHP Non-Clog Pumping Machinery |
| 10 | Providing, erecting, installing, testing and commissioning of factory-assembled electrical control panel (DOL / Star-Delta) suitable for operation of required HP, 415 Volts ±10%, 3-phase, 50 Hz squirrel-cage induction motor, complete with MCCB of adequate breaking capacity, copper bus bars, magnetic contactors, thermal overload relay (OLR), electronic single-phasing and phase-reversal preventer, under-voltage and over-voltage protection, dry-running protection through current sensing / water level relay, automatic reset / manual reset arrangement, ammeter and voltmeter with selector switches, R-Y-B LED indication lamps, start/stop push buttons, internal wiring with FRLS copper conductors, proper ferruling, brass cable glands, double earthing terminals, panel enclosure of CRCA sheet steel with IP-54 / IP-55 protection, including all accessories, testing, trial run and commissioning at site, complete in all respects as per relevant IS/IEC standards and directions of Engineer-inCharge.5600 LPM 25 BHp 12.00 mtr head |
| 11 | Providing, erecting, installing, testing and commissioning of factory-assembled electrical control panel (DOL / Star-Delta) suitable for operation of required HP, 415 Volts ±10%, 3-phase, 50 Hz squirrel-cage induction motor, complete with MCCB of adequate breaking capacity, copper bus bars, magnetic contactors, thermal overload relay (OLR), electronic single-phasing and phase-reversal preventer, under-voltage and over-voltage protection, dry-running protection through current sensing / water level relay, automatic reset / manual reset arrangement, ammeter and voltmeter with selector switches, R-Y-B LED indication lamps, start/stop push buttons, internal wiring with FRLS copper conductors, proper ferruling, brass cable glands, double earthing terminals, panel enclosure of CRCA sheet steel with IP-54 / IP-55 protection, including all accessories, testing, trial run and commissioning at site, complete in all respects as per relevant IS/IEC standards and directions of Engineer-in Charge.6750 LPM 12 mtr head 30.00 BHP |
| 12 | Providing, supplying, installing and commissioning of diesel engine driven auto-priming dewatering pump set model MBH LD 4L, complete in all respects. The pump shall be auto-priming centrifugal type having maximum discharge capacity of 150 m³/hr and maximum head up to 32 meters, suitable for handling solids up to 40 mm size, and operating at 1800 RPM. The pump shall be coupled with 23 HP diesel engine and provided with 100 mm diameter suction and delivery connections. The unit shall be equipped with vacuum assisted auto-priming system consisting of mechanically driven diaphragm vacuum pump of 50 CFM capacity, priming chamber with positive air separation arrangement and stainless steel components, and swing type discharge check valve of ductile iron with nitrile disc. The pump shall be provided with oil lubricated mechanical seal having silicon carbide rotating and tungsten carbide stationary faces, enabling safe dry run operation. The material of construction shall include CI casing (IS:210 FG 260), SS 304 impeller, SS 410 shaft and MS fabricated base frame. The scope shall include supply of complete pump set with engine, priming system, coupling, base frame with trolley, battery, fuel tank, NRV, suction and delivery pipes (minimum 5 m each), weatherproof canopy and all allied accessories, including installation, testing and commissioning at site, complete as per specifications and directions of Engineer-in-Charge. |
| 13 | Provision for Providing and fixing CI pipes, Specials and DI Sluice, NRV of required make i.e. IVC /VAG to be installed inside pump chamber for making connection with proposed pumping machinery complete in all respect.(For Storm Pumping Machinery) |
| 14 | Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 12.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes, SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame,Monorail, Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend)etc. complete in all respect. 21900 LPM 100 BHP Non-Clog Pumping Machinery |
| 15 | Supplying, erection, testing and commissioning of submersible motor pumping set non clog for sewerage having head 25.00 m as per the indicated requirements of discharge in LPM and power capacity in BHP as per IS marked including all accessories (like SS Pipes,SS Chain (Shackle Chain) ,SS Foundation Bolt, complete base frame, Monorail,Chain Guide Line, Auto Compiling, Duct Foot Bend (D/F Bend) etc. complete in all respec Discharge Capacity (LPM) - 5200 Power Capacity (BHP) - 50 |
| 16 | HSR Itmes Please Enable Macros to View BoQ information |