| 1 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles and removing the debris outside from defence land complete all as specified and directed. |
| 2 | Demolition of cement concrete or lime concrete (unreinforced) in ground floors and Pavings not exc 15 cm thick (below or above ground level ) and removing the debris outside from defence land complete all as specified and directed. |
| 3 | Taking down cement or cement lime plaster, any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed. |
| 4 | M&L for PCC 1:4:8, Type D-2 using 40mm graded aggregate as in foundation filling and mass concrete complete all as specified & directed. |
| 5 | M&L for walling of random rubble masonary, uncoused, well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified and directed. |
| 6 | All as per item No 05 above but except stone, built in cement mortar 1:4 complete all as specified and directed. (Old stone obtained from demolition shall be reused) |
| 7 | M & L for brick work with old size bricks, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed. |
| 8 | M&L for 20mm thick rendering on stone masonry surfaces or surface other than fair face of brick-work or on one side of lathing in CM (1:4), finished surfaces even and smooth without using extra cement complete all as specified and directed. |
| 9 | M&L 15mm thick rendering on fair faces of brick surfaces in CM (1:4), finished surfaces even and smooth without using extra cement complete all as specified and directed. |
| 10 | M&L for Flush pointing in cement mortar 1:4 to random rubble masonry ,uncoursed or brought upto courses complete all as specified and directed. |
| 11 | M & L for PCC 1:2:4, type B-0 using 12.5mm graded aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, all including necessary formwork complete all as specified and directed. |
| 12 | M&L for Providing precast cement concrete 1:2:4 type B-1 using 20mm graded aggregate set in cement mortar 1:6 in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in mortar complete with joints to match complete all as specified and directed. (Note:- The quantity of PCC Bond stone shall be deducted from stone masonry items above) |
| 13 | M&L for Broken stone / Boulder filling dry, hand packed tightly as in back of wall and raising (or lowering) to the required level complete all as specified and directed. |
| 14 | Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surface n.exc 40mm to face stones and dressing of face beds and joints,as specified,of random rubble walling,uncoursed or brought upto courses for Granite or Trap Stone complete all as specified and directed. |
| 15 | S & F 110 mm bore of pipe PVC (SWR) pipes single socket in any length as in weep holes etc complete all as specified and directed. |
| 16 | M&L for preparation of newly plastered surfaces of wall and applying two coats cement base paint over a coat of alkali resistant priming complete all as specified and directed. |
| 17 | M & L for 100 mm thick PCC 1:2:4, type B-2, (using 40 mm graded aggregate) as in path/hardstanding complete all as specified and directed. |
| 18 | M&l for PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate in surface channels and drains including necessary formwork complete all as specified and directed. Please Enable Macros to View BoQ information |