Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #55344654

Tender For Construction Of Mukhyamantri Solar Powered Lift Irrigation Scheme At Jhariya East Singhbhum,Jharkhand

Issued by Government Departments · Potka, Jharkhand
Tender Value
1.22 Crore
Estimated cost
Bid Submission
12 May 2026
0 days left
EMD
2.45 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Potka → Jharkhand
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Construction Of Mukhyamantri Solar Powered Lift Irrigation Scheme At Jhariya East Singhbhum,Jharkhand

BOQ

Name of Work:- CONSTRUCTION OF MUKHYAMANTRI SOLAR POWERED LIFT IRRIGATION SCHEME AT JHARIYA EAST SINGHBHUM,JHARKHAND
Sl. No. Item Description
1Solar Module Mounting (Galvanised Steel) surface structure ( For 10 Kw) having hot deep galvanised of zinc thickness 80 micron and as per IS4759 with C Channel 5 anti theft with per nut bolt of grade SS304,which should also withstand high wind velocity upto 150 km/hr or as per MNRE.(Approved rates by S.E. M.I. Circle Ranchi, through letter no.-138, dated -25/02/2025 (Or S.E. Circle M.I. Circle Chaibasa Lt 136 Dt 03/03/25))
210kWp SPV module of 330wP or higher rating, which must have Specification as per IS 14286/IEC 61215 .The module must have to quilify IS/IEC 61730 part I $ II (or having mechanical load test of 5400Pa) for safety purpose.Module to Module wattage mismatch in SPV Array shall be +/-3% and to qualify IEC TS 62804-:2015 for the detection of potential induced degradation and warranted for output wattage not less than 90% in 10yrs and 80% at the end of 25yrs as per MNRE.(Approved rates by S.E. M.I. Circle Ranchi, through letter no.-138, dated -25/02/2025 (Or S.E. Circle M.I. Circle Chaibasa Lt 136 Dt 03/03/25))
3USPC Controller with SPV module/VFD integrated with GPRS,having MPPT ,Protection IP 65 or above as per MNRE to run 10 HP AC induction motor pump set(Approved rates by S.E. M.I. Circle Ranchi, through letter no.-138, dated -25/02/2025 (Or S.E. Circle M.I. Circle Chaibasa Lt 136 Dt 03/03/25))
4Solar cable 4 mm2 used as per IS 694 or as per MNRE.(Approved rates by S.E. M.I. Circle Ranchi, through letter no.-138, dated -25/02/2025 (Or S.E. Circle M.I. Circle Chaibasa Lt 136 Dt 03/03/25))
5copper cable 95 mm2 used as per IS 694 or as per MNRE.(Approved rates by S.E. M.I. Circle Ranchi, through letter no.-138, dated -25/02/2025 (Or S.E. Circle M.I. Circle Chaibasa Lt 136 Dt 03/03/25))
6Copper cable 16 mm2 for earthing as per IS 694 or as per MNRE.(Approved rates by S.E. M.I. Circle Ranchi, through letter no.-138, dated -25/02/2025 (Or S.E. Circle M.I. Circle Chaibasa Lt 136 Dt 03/03/25))
7Supplying and commissioning of earthing and lightening arrestor and surge protection as per IS 3043, IEC 62305-3, AND IEC 63227 for 10 HP AC induction motor pump set.(Approved rates by S.E. M.I. Circle Ranchi, through letter no.-138, dated -25/02/2025 (Or S.E. Circle M.I. Circle Chaibasa Lt 136 Dt 03/03/25))
810 H.P. A.C. induction motor Solar pump set of having performance with respect to Total Head,Maximum Current,Capacity,Voltage Range etc as per MNRE guidelines. (Approved rates by S.E. M.I. Circle Ranchi, through letter no.-138, dated -25/02/2025 (Or S.E. Circle M.I. Circle Chaibasa Lt 136 Dt 03/03/25))
9Miscllaneous Accessories for Installation of 10 H.P. A.C. induction Motor Solar Pump (L.S)(Approved rates by S.E. M.I. Circle Ranchi, through letter no.-138, dated -25/02/2025 (Or S.E. Circle M.I. Circle Chaibasa Lt 136 Dt 03/03/25))
10Supplying ,installation and commissioning charge of Module and Structure for 10kW.(Approved rates by S.E. M.I. Circle Ranchi, through letter no.-138, dated -25/02/2025 (Or S.E. Circle M.I. Circle Chaibasa Lt 136 Dt 03/03/25))
11Maintenance for atleast 5 years or as per MNRE guidelines(Approved rates by S.E. M.I. Circle Ranchi, through letter no.-138, dated -25/02/2025 (Or S.E. Circle M.I. Circle Chaibasa Lt 136 Dt 03/03/25))
124\\" dia M.S Suction pipe (C.E. Lt-2873, DT-31/12/2013, (item-1))
13Supplying C.I. foot valve having single leather flap and gun metal seating. Valve shall be fixed on suction side of pump as per requirement including jointing material and hardware. 100 mm (Common Part-A, M-1063, (pg-134)
14G.I. Fittings (conforming to I.S. - 1879) [A] G.I. Bend 100 mm (Common Part-A, M-930(A-ix), (pg-92)
154\\" dia G.I. Flange (C.E. Lt-2873, DT-31/12/2013, (item-39)
16Providing double flange sluice valve( size 50mm to 1200 mm) confirming for IS - 2906 / 14846 including worm gear arrangements as per test pressure stainless steel spindle , caps,transportation etc. all complete with bypass arrangement -PN-1 (Dia.100mm) (Common Part A M1039(B)4, Pg-120)
17G.I. Fittings (conforming to I.S. - 1879) [J] G.I. Nipple 100 mm dia x 100 mm long (Common Part-A M-930(J-ix), (pg-94)
18G.M. Non Return Valve Horizontal (ISI marked) 100 mm dia wt. not less than 1.80 kg (Common Part A M-926(ix) (pg-91)
194\\" x 8\\"/10\\" Reducer (C.E. Lt-2873,dt-31/12/2013, item-96)
2010\\" M.S. Pipe (C.E. Lt-2873,dt-31/12/2013, Sl. No.-5)
21G.I. Fittings (conforming to I.S. - 1879) [D] Reducing Tee Plain (Taking Larger Dimension) 100 mm (Common Part-A, M930,(D)-(viii), Pg-92
22Providing and Supplying in standard lengths High Density Polyethylene Pipe (HDPE Pipe) Confirming to IS 4984/14151/12786/13488 (Latest Revision with necessary jointing materials like mechanical connector i.e. thread/ insert joint/ quick release coupler joint / compression fitting joint or flanged joints excluding coupler / specials and taxes). HDPE pipe of material grade PE80-PN10 . 250 mm dia (Common Part-A, M-1028, PG-104)
23Providing and Supplying ISI mark CI D/F reflux valves (Non Return Valves) of 250 mm dia with inspection charges,unloading from railway wagon, loading into truck transportation upto departmental stores / site unloading stacking etc complete reflux valve as per IS 5312 part I (1984) (Common Part-A, M1039, (A)-8, Pg-118)
2410\\"(250mm) Flange (C.E. Lt-2873,dt-31/12/2013, item-42)
2510\\"(250mm) M.S. bend(C.E. Lt-2873,dt-31/12/2013, item-47)
266\\" M.S. pipeTATA(C-class) (C.E. Lt-2873, dt-31/12/2013, Sl.No.-3)
27G.I. Fittings (conforming to I.S. - 1879) [A] G.I. Bend 150 mm (Common Part-A, M-930(A-ix), (pg-92)
28Providing and Supplying in standard lengths High Density Polyethylene Pipe (HDPE Pipe) Confirming to IS 4984/14151/12786/13488 (Latest Revision with necessary jointing materials like mechanical connector i.e. thread/ insert joint/ quick release coupler joint / compression fitting joint or flanged joints excluding coupler / specials and taxes). HDPE pipe of material grade PE80-PN10 . 110 mm dia (Common Part-A, M-1028, pg-104)
29Providing and Supplying in standard lengths High Density Polyethylene Pipe (HDPE Pipe) Confirming to IS 4984/14151/12786/13488 (Latest Revision with necessary jointing materials like mechanical connector i.e. thread/ insert joint/ quick release coupler joint / compression fitting joint or flanged joints excluding coupler / specials and taxes). HDPE pipe of material grade PE80-PN10 . 160 mm dia (Common Part-A, M-1028, PG-104)
30Providing double flange sluice valve size (150 mm) confirming for IS - 2906 / 14846 including worm gear arrangements as per test pressure stainless steel spindle , caps,transportation etc. all complete (Common Part A M1039(B)6, Pg-120)
31G.I. Fittings (conforming to I.S. - 1879) [E] Socket Plain 100 mm (Common Part A M930(E-ix) Pg93)
324\\" PVC Tee(C.E. Lt-2873, dt-31/12/2013, Sl.No.-105)
334\\" PVC Tail piece(C.E. Lt-2873, dt-31/12/2013, Sl.No.-65)
34Solvent Cement(Sl No.134) (C.E. Lt-2873,dt-31/12/2013, item-134)
35M-Seal(Sl No.136) (C.E. Lt-2873,dt-31/12/2013, item-136)
36E/W in excavation in foundation trenches in ordinary soil (vide classification of soil item -A) and disposal of excavated earth as obtained to a distance upto 50 m. including all lifts, levelling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I. (5.1.1. BCD)
37Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) (5.1.10. Part A)
38Filling in foundaion trenches and plinth in layers not exceding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) (5.1.7 BCD)
39Supplying labours and tools for laying and jointing H.D.P.E. pipes in trenches and making butt welded joint, supplying heating mirror, jack etc and providing night guard, barrier and red light to safe guard against accident all complete as per specification and direction of E/I. 210/200mm dia Phed Part B (3.1.37 E) Page-114
40Supplying labours and tools for laying and jointing H.D.P.E. pipes in trenches and making butt welded joint, supplying heating mirror, jack etc and providing night guard, barrier and red light to safe guard against accident all complete as per specification and direction of E/I. 110/100mm dia Phed Part B (3.1.37 B) Page-114
41L/C for fitting and fixing of 125 mm to 150 mm dia C.I. foot valve or flange (all of standard make with or without check) in position with respective 125 mm to 150 mm dia G.I. pipe including supply of 22 mm thick rubber packing and proper size of nut and bolts of hard steel, including marking of valve seat etc complete job including carriage of materials from site godown to work site as per specification and direction of E/I. (WRD 8.1) Page-155
42L/C for fitting and fixing 150 mm dia all pressure P.V.C. tail piece (All of standard make) in posiotion including carriage from site godown to the work site, tools and plants etc. all complete as per specification and direction of E/I. (WRD 8.62)Page-159
43L/C for fitting and fixing of 125 mm to 150 mm dia G.I. M.S. bend of any degree with 125 mm G.I. or M.S. pipe (All of standard make) including threading if required and carriage to site godown all complete job, leak proof,as per specification and direction of E/I. (WRD 8.5)Page-155
44L/C for fitting and fixing 200mm/250mm G.I. Reducing socket (all of standard make) in position including cost of hard steel nuts and bolts of proper size , rubber packing, safed etc including cost of carriage from site godown to work site and T&P, all complete job leak proof as per specification and direction of E/I.(WRD 8.85)Page-155
45L/C for fitting & fixing 150 mm x 150 mm x 150 mm P.V.C Tee ( of standard make) of all pressure in position including carriage from site godown to work site tools and plants etc all complete job as per specification and direction of E/I.(WRD 8.67)
46L/C for fitting and fixing sluice or N.R. valve 125 mm dia (all of standard make) in series (only one end) in position including cost of hard steel nuts and bolts of proper size in 10 mm thick rubber packing, safed etc and also including cost of carriage from site godown to work site tools and plants etc , all complete leak proof as per specification and direction of E/I.(WRD 8.12) PAGE-156
47Labour charge for fitting and fixing 250mm dia. Sluice or N.R valve (all of standard make) in position (both ends) including cost of hard steel nuts and bolts of proper size in 10 mm thick rubber packing, safed etc and also including cost of carriage from site godown to work site tools and plants etc , all complete leak proof as per specification and direction of E/I. (WRD 8.17) page-156
48Labour charge for threading of pipes 200 mm dia including carriage from site godown to work site as per specification and direction of E/I.(WRD 8.88)
49Providing Angle (75x75x8 ) @ 8.9kg/M ….do…do -… E/I.(M-195(P-40) WRD)
50Providing Barbed wire of 4 point ,2 ply 12 swg , 150 mm apart all complete job. As per specification and direction of E/I. (M215 P56 SN.31 COMMON PART A)
51Labour for cutting of MS angle iron post to require length, one end splitted as fishtailed in a length of 150mm complete as per building specification and direction of E/I. (5.5.24 BCD PART B)
52Drilling 6mm dia holes MS angle iron for fixing of staples etc as as per building specification and direction of E/I.(5.5.23 BCD PART B)
53Labour for fitting and fixing barbed wire fencing in 6 rows,horizontal upto aheight of 1.85 M and 2 Diagonals including fixing of post in cement concrete at 2.5 M centres including cost of staples as per building specification and direction of E/I.(5.5.22 BCD PART B)
54Supplying, Fitting and fixing M.S. grill gate M.S grill made of 20 x 6mm M.S. flat or 16 mm M.S. square bars fitted on 25x25x6 mm M.S. angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.(5.5.30 BCD PART B)
55Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B)(5.1.1 + 5.1.2 B.C.D)
56Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.(5.6.3 B.C.D)
57Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)(5.3.1.2 B.C.D)
58Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). (5.3.10 B.C.D)
59Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size). (5.3.9.1 B.C.D)
60Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete. (5.3.17.1 B.C.D)
61Centering and shuttering including strutting, propping etc. and removal of form for Columns, Pillars, Piers, Abutments, Posts and Struts. (5.3.17.6 B.C.D)
62Providing designation 75 B brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.(5.2.14 B.C.D)
63Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.(5.7.3 B.C.D)
64Providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL)(5.5.4 (a) BCD PART B)
65Providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. (a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}(5.5.5 (a) BCD PART B)
66Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper scaffolding , curing and taxes all complete as per building specification and direction of E/I. (5.8.24 B.C.D)
67Stone crusher dust finer than 3mm with not more than 10% passing 0.075 Sieve at Quarry .(RCD M-004)
68Providing and laying 80mm thick factory made cement concrete interlocking paverblock of M 40 grade made by block making machine with strong vibratory compaction of approved size design and shape laid in required colour over bed as per relevant IRC code, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge RCD4.23B
69Supplying labour and equipment for digging well (vide classification of soil item-A) including removing the spoils to a safe distance upto 50 m from the edge of the well all complete as per specificition and direction of E/l. (A) E/W up to 3 metre depth below G.L.(3.1.64 PHED PART B)
70Supplying labour and equipment for digging well (vide classification of soil item-A) including removing the spoils to a safe distance upto 50 m from the edge of the well all complete as per specificition and direction of E/l. (i) 3M to 4M (3.1.64 PHED PART B)
71Supplying labour and equipment for digging well (vide classification of soil item-A) including removing the spoils to a safe distance upto 50 m from the edge of the well all complete as per specificition and direction of E/l. (ii) 4M to 5M (3.1.64 PHED PART B)
72Supplying labour and equipment for digging well (vide classification of soil item-A) including removing the spoils to a safe distance upto 50 m from the edge of the well all complete as per specificition and direction of E/l. (iii) 5M to 6.00M(3.1.64 PHED PART B)
73Supplying labour and equipment for digging well (vide classification of soil item-A) including removing the spoils to a safe distance upto 50 m from the edge of the well all complete as per specificition and direction of E/l. (iv) 6M to 6.25M (3.1.64 PHED PART B)
74E/W in filling in foundation trenches or back filling of masonary structures with suitable earth in layers not exceeding 150 mm thick well watered rammed and fully compacted and finally dressed with earth obtained from excavation of foundation trenches and kept at a lead of 30 m and initial lift of 1.5 m complete as per specification and direction of E/I.(6.1.16 WRD PART B)
75Providing rough dressed coarse stone masosry in cm. (1:4) in superstructure with approved quality of coarse sand of requisite rn (2.5 to 3) washed and screened with risking out joints to 12mm depth, curing scaffolding and its removal where required royally and all taxes etc. complete Job as per specificition and direction of E/l. (5.2.31 BCD PART B)
76Supplying materials and labour for providing R.C.C well curve(1:2:4) including centering and shuttering but excluding the cost of reinforcement all complete as per specification and direction of E/I.(3.1.68 PHED PART B)
77Supplying and laying boulder in rock toe in trenches of the dam as per design, drawing including the cost of materials royalty and taxes etc. but excluding the cost of carriage all complete as per specification and direction of E/l.(5.6.4 COMMON PART A SL NO 6.4)
78Supplying and laying sand filter blanketing in horizontal portion of the dam as per design drawing and specification and direction of E/l.(5.6.1 COMMON PART A SL NO 6.1)
79Supplying and laying gravel filter (size 5mm to 15mm) in filter blanket and in the toe drain (in horizontal portion) of the dam as per design, drawing including the cost of materials but excluding the cost of carriage as per specification and direction of E/l.(5.6.2 COMMON PART A SL NO 6.2)
80Supplying and laying good quality of stone metal filter (20mm to 63mm size) in the rock toe, heel trenches, toe drain as per design drawing and specification and direction of E/l.(5.6.3 COMMON PART A SL NO 6.3)
81Labour charge for fitting and fixing 600mm x 300mm C.I. grating in the steining walls of intake well as per specification and direction of E/I.(8.59 WRD PART B)
82Providing 25mm precast R.C.C. M-150 with nominal mix of (1:2:4) jali with approved quality of stone chips of 6mm nominal size and properly grouted with cement mortar (1:3) including cost of curing, scaffolding and finishing all complete as per building specification and direction of E/l.(5.3.21.3 BCD PART B)
83Supplying materials and labour for fixing 20mm dia M.S. bar steps in steining wall of 0.30 M interval and staggered in (1:2:4) cement concrete including scaffolding and curing etc. all complete as per specification and direction of E/I.(3.1.71 PHED PART B)
84Providing 25mm thick cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.(5.7.12 BCD PART B)
85Providing R.C.C. M-200 with nominal mix of (1:1½:3) in beam of all types with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of requisite F.M (2.5 to 3) including screening, shuttening, mixing cement mortar in mixer and placing in position, vibriting, striking, curing (but excluding the cost of reinforcement) tax and royalty all complete as per building specification and direction of E/l.(5.3.11 BCD PART B)
86Hire charge of diesel operated pump for bailing out of water during construction all complete as per building specification and direction of E/l.(PM-29 SN.10 Pg-83 WRD PART B)
87Providing coarse clean local sand filling in foundation trenches including ramming watering royalty and all other taxes complete job as per specification and direction of E/I.(7.1.37 WRD PART B)
88Providing brick flat soling with designation 75 A brick, joints filled with coarse sand of approved quality including royalty and all taxes all complete job as per specification and direction of E/I.(7.7.14 WRD PART B)
89Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)(5.3.9.2 BCD PART B)
90Providing designation 75A brick work in C.M (1: 6) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I.(5.2.3 BCD PART B)
91Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand(zone-III) : 4 graded stone aggregate 20mm nominal size).(5.3.5 BCD PART B)
92Providing designation 75 A brick work in C.M. (1: 6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.(5.2.11 BCD PART B)
93Providing 50mm thick 2nd class patent stone flooring (1:2:4) with 20mm, to 6mm size graded stone chips finished with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.(5.6.9 BCD PART B)
94Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I.(5.5.29 BCD PART B)
95Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.)(5.5.12 BCD PART B)
96Providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing inclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. (a) 10mm (TMT coil Fe 500) (only valid for Tata (Tiscon), SAIL, JSPL,Electrosteel Steels Ltd. Bokaro and Vizag (RINL)}(5.5.5 (b) BCD PART B)
97Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.(5.7.6 BCD PART B)
98Providing primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dust, dirt, scales smokes and grease and cleaning the surface throughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurement area shall be multiplied by the co-efficient as indicated in building specification)(5.8.41 BCD PART B)
99Providing two coat of painting with ready mixed paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I.(5.8.43 BCD PART B)
100Providing designation 75 A brick work in C.M. (1: 4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including, providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.(5.2.10 BCD PART B)
101Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.(5.7.1 BCD PART B)
102Providing shuttering including structing, propping etc. and its removal after use in foundation work as per as per specification and direction of E/l.(5.3.17 WRD)
103Providing shuttering including structing, propping etc. and its removal after use in super structure portion of various components of dam work as per specification and direction of E/l.(5.3.18 WRD)
104Providing 12mm cement plaster (1:4) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.(5.7.2 BCD PART B)
105Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I.(5.7.11 BCD PART B)
106Point wiring in PVC Cunduct with Piano Type switch. Wiring for Light point, fan point, exhaust fan point, call bell point with 1.5 sq mm FR PVC insulated copper cunducter sigle core in surface/recessed PVC cunduit, piano type switch, phenolic laminated switch with suitable size PVC/MS box etc. as required. (1.1.1 Group A) Energy PART B
107S.I.T.C. of floowing rating LED Street lighting laminarie with pressure die cast housing and toughened glass cover, IP 66 protection, Luminous EFFICARY greater or equal to 110 LM/W with lens in existing pole/pipe for supply voltage 110 - 270 V AC, 50 Hz, Luminarie shall be confirmed to IS:10322 part - 5/ Section - 3 and shall be complete with all necessary accessories as required.30W Led Street Light. 9.1 (9.1.3) Energy PART B.
10863A TPM 415/440 V main switch .( C.E.Lt-2873, dt-31.12.2013)S.L NO-187
109Voltmeter - 500 V ( C.E.Lt-2873, dt-31.12.2013)S.L NO-188
110Ampere Meter - 60 A ( C.E.Lt-2873, dt-31.12.2013)S.L NO-189
111Wooden panel board for fitting main switch, volt meter, amp. meter etc. ( C.E.Lt-2873, dt-31.12.2013)S.L NO-202
1127/20 Copper Wire, ( C.E.Lt-2873, dt-31.12.2013). S.L NO-194
1137/18 Copper Wire ( C.E.Lt-2873, dt-31.12.2013)S.L NO-197
114Batten Holder. ( C.E.Lt-2873, dt-31.12.2013)S.L NO-194
1155 Ampere switch.( C.E.Lt-2873, dt-31.12.2013)S.L NO-214
116100 Watt Bulb.( C.E.Lt-2873, dt-31.12.2013)S.L NO-203
117PVC Tape.( C.E.Lt-2873, dt-31.12.2013)S.L NO-195
1181½\\" P.V.C. Flexible Pipe.( C.E.Lt-2873, dt-31.12.2013)S.L NO-199
11963A Copper bushbar - 3 Phase 4 Pole( C.E.Lt-2873, dt-31.12.2013)S.L NO-201
120Carriage of materials: -(i) Sand -
121(ii) Cement -
122(iii) Stone Chips -
123(iv) Bricks -
124(v) Paver Blocks -
125(vi) Stone Metal -
126(vii) Boulder -
127Add GST @ 18% on S.N 12 to 126 only
128Add Labour Cess @1% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55344654
AUTHORITY Government Departments
TENDER VALUE 1.22 Crore
LAST DATE 12-05-2026
Authority
Authority Name Water Resources Department
Work Description Tender for Construction Of Mukhyamantri Solar Powered Lift Irrigation Scheme At Jhariya East Singhbhum,Jharkhand
Basic Detail
Tender No WRD/MID/JAMSHEDPUR/F2-01/26-27
Bidding Type Tender
Location
City Potka
State Jharkhand
Key Dates
Publish Date 05 May 2026
Submission Date 12 May 2026
Open Date 14 May 2026
Finance
Tender Value 1.22 Crore
Tender Fee 10000
EMD 2.45 Lakhs
Exemption Available
Document List
613ebc50-4a53-4741-9674-07d373779299.html
BOQ_153493.xls
SOP-GUIDELINE.pdf
TENDER-DOCUMENT.pdf
Tendernotice_1 (8).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 05, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
May 12, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

613ebc50-4a53-4741-9674-07d373779299.html

xls

BOQ_153493.xls

pdf

SOP-GUIDELINE.pdf

pdf

TENDER-DOCUMENT.pdf

pdf

Tendernotice_1 (8).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender