| 1 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as reqd. |
| 2 | P&F 25 mm X 5 mm G.I. strip on surface or in recess for connection etc. as reqd. |
| 3 | S&F of full stainless steel body self-contained drinking water cooler with cooling capacity 150ltr per hr, storage capacity 150ltr and suitable for 230V supply as reqd. |
| 4 | P&L in position cement concrete 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as reqd. |
| 5 | 6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand) |
| 6 | S&L of following size of C PVC pipe in along with all accessories like socket, bend, couplers etc. conforming to IS :4985:2000, Part II complete with fitting and cutting, jointing etc. direct in ground ( 50 cm below ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. 25 mm dia |
| 7 | Wiring for light / power plug with 2 X 4 sqmm FRLSPVC insulated copper conductor single core cable in surface / recessed steel conduit alongwith 1 no 4sqmm FRPVC insulated copper conductor single core cable for loop earthing as reqd. |
| 8 | S&F suitable size GI box with modular plate and cover in the front of surface or in recess including providing and fixing 6 pin 5/6 and 15/16A modular socket outlet and modular 15/16A modular switches connections etc as reqd. |
| 9 | S&F following rating, Two pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.(a) 25 Amp. |
| 10 | P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. |
| 11 | P&F of Stainless steel name plate of size 6x8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as reqd |
| 12 | Supplying AND Installation of Reverse Osmosis (RO) water purifier of capacity 50 ltr/hr complete as reqd. |
| 13 | S&F 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as reqd. SPN |
| 14 | P&F name board made of MS Sheet 90x60 cm, 1mm thick with frame of MS angle 50x50x6mm, two diagonal braces at the back of the sheet of MS flat 40x6 mm, total height of the board above ground level 2.4 metre, length of legs below ground 0.3 m embedded in CC Block 1:2:4 ( 1 Cement: 2 Coarse sand : 4 Graded stone aggregate 20 mm nominal size ) 20x30x45 cm i/c excavation and removal of surplus earth with in 50 m lead, applying priming coat of approved steel primer, painting with synthetic enamel paint of approved quality and lettering with enamel paint of approved colour ( one side) as per drawing/direction of Engineer-in- Charge. Please Enable Macros to View BoQ information |