| 1 | Supply and fixing in repairs LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete all as specified and directed. |
| 2 | All as per item No. 1.00 above but 90 watt |
| 3 | All as per item No. 1.00 above but 100 watt |
| 4 | All as per item No. 1.00 above but 120 watt |
| 5 | All as per item No. 1.00 above but 150 watt |
| 6 | Supply and fixing in repairs LED flood light 30 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver etc all as specified and directed. |
| 7 | All as per item No. 6.00 above but 50 watt |
| 8 | All as per item No. 6.00 above but 100 watt |
| 9 | All as per item No. 6.00 above but 150 watt |
| 10 | All as per item No. 6.00 above but 200 watt |
| 11 | Supply and fixing in repairs LED high bay light 100 watt 230 V AC UFO type outdoor with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver etc all as specified and directed. |
| 12 | Supply and fixing in repairs LED high bay light 200 watt 230 V AC UFO type outdoor with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver etc all as specified and directed. |
| 13 | Supply and fixing in repairs post top lantern LED type 20/ 25 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete |
| 14 | Supply and fixing in repairs post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete |
| 15 | S&F in repairs, connecting and testing decorative LED Bollard light with opal diffuser & aluminium reflector of 8/ 10watt 2 Feet LED including nut, bolts, washers, clamps etc complete all as specified and directed by Engr -in-charge. |
| 16 | S&F in repairs, Aesthetically designed decorative hot dipped galvanised mild steel step 3.5M pole with grey powder finish, Compatible for post top range. Window - Plasma cut & duly chamfered opening window of 300x110 mm for terminal connections & mounting accessories Window cover is fitted with allen screws to the pole including fdn bolts and RCC foundation of size 600x600x600mm with RCC 1:2:4 type B1 using 20 mm graded stone aggregate complete all as specified and as directed. Make Havells cat no - DECO POLE 3.5M TOP 76Ø or equivalent in Bajaj / Philips/ Crompton. |
| 17 | S&F in repairs, 60W Circular LED post-top offering excellent uniform illumination and aesthetics in one go Made up of Pressure Die Cast aluminium body and opal PC cover., IP 66 and IK 07 rating complete all as specified and as directed. Make Havells cat no RINKPT60WLED757PSYMTOPC or equivalent in Bajaj / Philips/ Crompton |
| 18 | Dismantling and taking down carefully from its position street light/ perimeter lighting luminaries such as LED/ fluorescent tube/ HPSV lamp type of any wattage and description from over head line distribution feeder poles for carrying out repairs or replacement of burnt/ worn out accessories and removing unserviceable items from fitting including material and labour for replacement worn out wiring of the accessories in the control gear with PVC insulated copper conductor single core cable of required size, connector block, screws etc. Refixing the luminaries after repairs, testing and commissioning to their position or as directed by Engr-in-Charge.Note: (a) Accessories/ Components requiring replacement shall be measured and paid separately under respective item of Sch ‘A’ |
| 19 | Supply and fix in replacement driver suitable for LED light of capacity 50 to 70 watt as per existing make. |
| 20 | Supply and fix in replacement driver suitable for LED light of capacity 75 to 90 watt as per existing make. |
| 21 | Supply and fix in replacement driver suitable for LED light of capacity 95 to 120 watt as per existing make. |
| 22 | Supply and fix in replacement driver suitable for LED light of capacity 150 to 200 watt as per existing make. |
| 23 | Supply and fix in replacement surge protection device of 10 KV rating compatible with industrial and outdoor fittings with rated power up to 150 w all as specified and directed. |
| 24 | Material and labour for replacement of unserviceable street light bracket made out of GI pipe 1.2 mtr long 40mm dia light grade bent to shape as directed including MS clamps made out of 40mmX6mm flat iron for fixing bracket suitable for PCC/ street poles including nuts and bolts of required size all as directed incl taking down of old Unsv bracket |
| 25 | S & F in replacement hot press moulded SMC junction / terminal box of size with internal dimensions of 240 x 190 x 110 mm with hinged door, incl provision of 2 way connector 415 Volts made out of polycarbonate or Bakelite and 1 No MCB of 6 Amps with DIN bar, drilling holes for cable connections, connecting incoming and or out going cables by providing suitable of size of cable lugs/ glands, fixed on pole by means of clamps made out of MS flat iron of size 25 mm x 3 mm including dismantling of old unserviceable all as specified and as directed. |
| 26 | Supply and fixing in replacement off multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 1.5 Sqmm, 3 core panel to street light inside/ outside pole complete all as specified. |
| 27 | Supply and fix in replacement of MCB SP 6 to 32 Amp 10 KA C Curve |
| 28 | Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/ wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor, MCBs and copper circuit wiring (min.10sqmm) should enough to take: three-phase load of 12-15KW;contactor Rating 32Amps; MCB(spn) Rating 32Amps. Healer Enterprises Model no SWADEEP-02EC12KW3P or equivalent in Seimens and Havells. |
| 29 | Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/ wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor, MCBs and copper circuit wiring (min.6sqmm) should enough to take: three-phase load of 8-11KW;contactor Rating 20Amps; MCB(spn) Rating 20Amps. Healer Enterprises Model no SWADEEP-02EC8KW3P or equivalent in Seimens and Havells. |
| 30 | Supply & fixing in replacement of automatic street light switch using Nature Switch for automatic switching of street lights based on LUX level of natural light the sensor (nature switch) along with suitable power contactors and MCBs (Input-output) should be enclosed in pole/ wall mountable enclosure made of rust proof, Electric shock proof, termite proof and FR grade SMC junction box (sintex make) conforming to IP 54.the contactor, MCBs and copper circuit wiring (min.6sqmm) should enough to take: single-phase load of 5-8KW;contactor Rating 40Amps; MCB(spn) Rating 32Amps. Healer Enterprises Model no SWADEEP-02EC8KW1P or equivalent in Seimens and Havells. |
| 31 | S&F in replacement of XLPE insulated armoured heavy duty electric cable with aluminium conductor stranded of size 10 Sqmm 2 core. |
| 32 | All as per item 31.00 above but 10 sqm 4 core. |
| 33 | All as per item 31.00 above but 16 Sqmm x 2 core. |
| 34 | S&F in replacement of GI pipe light grade 40mm bore for cable protection complete all as specified and directed |
| 35 | Excavation in trenches n.exc 1.5 mtr in depth and n.exc 1.5 m in width in any type of soil for laying cables and getting out complete all as specified. |
| 36 | All as per item No 35.00 above but depth exc 1.5 mtr but not exc 3 mtr. Please Enable Macros to View BoQ information |
| 37 | All as per item No 35.00 above but depth exc 1.5 mtr but not exc 3 mtr. Please Enable Macros to View BoQ information |