| 1 | Design, Drawing, fabrication, supply, erection, testing and commissioning of Vertical lift fix wheel type sliding gate/inter changeable Stop log gates consisting of skin plate, stiffeners, horizontal girders, pulley, pulley supports, bracings, lifting lug, bracket, rubber seals, clamps plates etc., with all accessories as per relevant for Canal , sluice Vertical gates and spillway gates including cost of all materials, machinery, labour, cutting, bending, aligning, anchoring, welding, seal fixing, tools and tackles etc., finishing, cleaning, applying two coat of zinc rich epoxy primer to give dry film thickness of 70± 5 microns and finish coat(two coats)of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150± 5 microns per coat thus total dry film thickness of all coats, including primer coating, should not be less than 350 microns., complete as per specifications and approved drawings complete, including packing & forwarding, transportation charges for structural steel components and other materials. |
| 2 | Design, Drawing, fabrication, supply, erection, testing and commissioning of Adequate capacity Electrically operated screw type hoist according to relevant IS code, consisting of supporting structure, platform bridge etc., operating handle ,gate position indicator, plumber block, couplings, motor, reduction gear unit, limit switch, control panel, cables, with inbuilt manually operation with all required accessories for operating Head/cross/ escape regulator gate including cost of all materials, machinery, labour, tools and tackeles, cutting, aligning, anchoring, welding, finishing, cleaning, greasing, oiling, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings with all lead and lifts, including packing & forwarding, transportation charges for all materials |
| 3 | Painting of Spillway gates, sluice gates, canal gates (both vertical or radial), stop log gates, exposed embedded parts and all un machined ferrous surface ( hoist cylinders, cylinder heads, hydraulic piping, pipe fittings , bonnet covers),exposed to water as per IS 14177, for which surface preparation by blast cleaning of class “B” primer coat (one coat) of inorganic zinc silicate (preferably airless spray) or alternatively, two coats of zinc rich primer (containing not less than 85% zinc on dry film) to give dry film thickness of 70 ± 5 micron and finish coat (two coats) of solvent less coal tar epoxy paint using airless spray to provide dry film thickness of 150± 5 micron per coats. Thus, total dry film thickness of all the coats, including primer coating, should not be less than 350 microns; this will include expenses on mobilization and demobilization of equipments. For maintenance painting the surface preparation shall be done by appropriate hand And power tool cleaning, prior to hand power tool cleaning. Any heavy layer of rust should be removed by chipping visible oil, grease, dirt and other foreign material be cleaned using solvents like clean mineral spirits, xylot or white gasoline. After hand and power tool cleaning the surface should be cleaned of loose dust and debris and /or blast cleaned as laid down in para 7.0 of IS code 14177.After the surface preparation the primer and finishing coats shall be carried out as provided above for painting etc. completeUpto 1.5M Height |
| 4 | Beyond 1.5M Height |
| 5 | Painting of machinery, including gearing, housing, shafting, bearing, pedestals, oil tanks, control cabinets, hoist beams, pipe support, clamps, ladders etc., of hoists and supporting structures, asupto 1.5 m height |
| 6 | Beyond 1.5M Height |
| 7 | cleaning gates /hoist /embedded parts for repainting by removing rust oil, paint grease etc . By using wire brush , scrubber , rust remover and applying a coat of rust remover and applying a coat of rust inhibitive compound etc. complete |
| 8 | Supplying and fixing bulb type Teflon cladded rubber seals and stainless steel counter sunk bolts/ nuts/ washers of approved quality |
| 9 | Supplying and fixing flat rubber seals and stainless steel counter sunk bolts/ nuts/ washers of approved quality including cost of all materials, labour, removing existing worn-out/ damaged flat type rubber seals, from gates, cleaning surface, making holes in new seals, fixing new seals/ bolts/ nuts/ washers tightly in position, scaffolding etc. Complete. R/C gate size 12×5m |
| 10 | Supply ,installation of PV Module 75 Wp Under STC ,MNRE Approved 012 Battery, Minimum 360 Wh LiFePo4 Battery, BIS Certified, 30AH/12.8 Volt013 12 Watt, W-LED luminary, Light(White LED based Light) 01 , Erection of System with 5 Year warranty as per MMRE technical specification. |
| 11 | Supply of steel tubular pole swaged type as per IS:2713- 1980 Complete with base plate and top Canopy42.3.1 410 SP-2 - 7 metre Each 7761.00 8623.00 |
| 12 | Supplying and fixing of 32 mm dia. X 2.00 meter long G.I. Pipe (Medium class bracket for mounting of fluorescent / S.V/M.H/L.E.D lamp steet light fitings on poles including bending the pipe to the required shape and wiring with 1.5 sq.mm W.P./PVC wire etc. as required. |
| 13 | Designing and construction of footing foundation for octagonal pole of desired size including excavation in soil/soft rock, base concrete M-7.5 (1:4:8), 15mm thick and pedestal of RCC M-20 (1:1.5:3), required tar steel reinforcement for required size from base concrete, |
| 14 | Supply & fixing anti climbing device with 2 ply G.I. barbed wire 1 Kg. per pole complete as per MPMKVVCO. Specification. |
| 15 | Supplying, installing, testing and commissioning of Lightning protection system with Early Streamer Emission (ESE), OPR (Optimized Pulse Rod) technology, of protection level -1, having a coverage range and mounted at a height as mentioned below including stainless steel mast & mounting structure kit as per specifications.OPR 30, radius 67Mt., Height 3 Mt |
| 16 | OPR 60, radius 97Mt., Height 3 Mt |
| 17 | Supplying, installing, testing and commissioning of Lightning Discharging Counter to verify the lighting discharge occurrence. |
| 18 | Providing & fixing 25mm X 5mm G.I. strip in 40mm dia G.I. Pipe(B class) from earth electrode as required. |
| 19 | Supplying and erecting earth pit of minimum bore dia. 150mm size , approved make Safe Earthing Electrode consisting Pipe-in-Pipe technology as per IS 3043-1987 made of corrosion free G.I. Pipes with constant ohmic value surrounded by highly conductive compound with high charge dissipation suitable for effective and maintenance free earthing as mentioned below : With 3 mtr. Pipe of 80mm outer dia. , 40mm inner dia and 14mm terminal dia. In soft rock/marshy soil with 50 kgs.(Two Bag) Back filling Compound. |
| 20 | Providing and fixing of limit switch |
| 21 | Providing and fixing DOL startar reverse forward type for 5 hp motor |
| 22 | Providing and fixing MPCB of type 3RB2032-4DA10 (18-25 Amp) |
| 23 | Providing and fixing of Penal Enclouser double door type |
| 24 | Providing and fixing of HRC fuse with holder |
| 25 | Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make.Supplying and laying of submersible flat cable ISI marked 3 core copper wire of suitable size with proper clamping of approved make.4.0 sq.mm |
| 26 | Providing and fixing of control & power wiring as per required size & length at site |
| 27 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor of 25 Sq. mm armoured type 3½ core. |
| 28 | Supplying and fixing PVC conduit ISI marked FRLS along with accessories on surface etc. as required 20 mm. MMS PVC conduit 20 mm. (MMS) |
| 29 | Supplying and fixing PVC conduit ISI marked FRLS along with accessories on surface etc. as required 40 mm. MMS |
| 30 | Supply and fixing street light with high power LED of 3 to 6 Watt each on existing bracket assembled on single MCPCB and additional unique peanut lens on each LED, system lumens output with efficacy>120 lm/Watt. luminiare having color temp upto 6500K & 50000 hrs. burning life with minimum @ L 70, The colour rendering index of LED light should be more than 70. Luminiare comprises of driver, PF> 0.95 & surge protection 10KV. Housing made of pressure die cast aluminium with heat resistant flat glass, IP65 protection. Submission LM 79- 08/IS16106 (2012), IEC60598, IEC61347 i/c connection wire, testing etc. to complete the job. 90Watt, color temp 3000-6500k as required. |
| 31 | Supplying and fixing of 32 mm dia. X 2.00 meter long G.I. Pipe (Medium class bracket for mounting of fluorescent/ S.V/ M.H /L.E.D lamp steet light fitings on poles including bending the pipe to the required shape and wiring with 1.5 sq.mm W.P./PVC wire etc. as required. |
| 32 | Supply of steel tubular pole swaged type as per IS:2713- 1980 Complete with base plate and top Canopy 410 SP-2 - 7 metre Each |
| 33 | Providing and fixing of 100 Amp SFU |
| 34 | Supplying of ISI Marked and approved make of Moulded Case Circuit Breaker (MCCB) suitable for 3 phase, 3 pole, 50 Hz, 415 Volts , AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828 MCCB with Breaking Capacity 25 KA at 415 V Current Rating -63 Amps |
| 35 | Supplying of ISI Marked and approved make of Moulded Case Circuit Breaker (MCCB) suitable for 3 phase, 3 pole, 50 Hz, 415 Volts , AC supply with respective interrupting capacity (KA) at 415 Volts cited against their range standard conforming to IS – 8828 MCCB with Breaking Capacity 25 KA at 415 V Current Rating -200 Amps |
| 36 | Supplying of ISI Marked On-Load Change over switches panel mouniting type confirming to IS : 13947 (part I & III ) with front operated 4 pole, 415 V with two earthing terminals if required. 200 Amps |
| 37 | Supplying, fixing, testing & commissioning wall / floor mounted LT Panel primer coated with powder coated paint & provided with required gasket for dust / vermin proof with degree of protection IP42 suitable for 415V 3 phase, 50 Hz, 4 wire system fabricated out of CRCA sheet up to 2 mm thick (1.6 mm for doors) duly compartmentalized for Providing & fixing of Distribution Panal for Thawar Dam ESTIMATE incomer, bus section, outgoings, cable alleys & CT, PT Ampere Meter, Volt Meter, selector switches, Frequency Meter, phase indicating lamps, Energy Meter complete including cost of busbar supports, detachable cable gland plates, 2 earthing terminals, internal wiring & fixing of separately supplied MCBs, MCCBs , ACB, panel mounted Changeover switch / SFUs, etc. as required but excluding cost of bus bar strips, Ampere Meter, Volt Meter, Selector switch as per approved design & specification |
| 38 | Supplying and fixing of LT Panel accessories of approved make in existing LT Panel including connections etc.as required as per spececificationDigital Ampere Meter with CTs with selector switch |
| 39 | Digital Volt Meter with selector switch & HRC fuse |
| 40 | Frequency Meter |
| 41 | Copper bus bar strips with PVC sleeves |
| 42 | LED lamp indicator |
| 43 | Supplying & Installation of Five star BEE rating ISI Marked required capacity of Three phase, 50 Hz, 415V, Open well Submersible pump, with Control Panel Starter with Dry Run Protection, single phase preventer, connections, etc. as required as per specifications but excluding pipe and connection cable.5.0 H.P. Head Mt.15-24, Discharge LPM 930-420 |
| 44 | Providing laying and jointing of following galvanized Iron (MS) Pipes with specials (such as bends, elbows, tees etc) class light, medium & heavy including testing of joints, cost of pipes, specials and jointing materials all complete. Pipes and sockets conforming to IS-1239/2011 Part- II25mm dia R Mtr. (Heavy) |
| 45 | 20 mm dia R Mtr. (Heavy) |
| 46 | Providing and fixing following class-II Globe wheel valves, confirming to IS 778/1984 (Reaffirmed 2005), tested to 21.09 kg/sq.cmt.25 mm dia Each 1053.00 |
| 47 | 20 mm dia Each 1053.00 |
| 48 | Supplying and laying of submersible flat cable ISI marked 3 Core copper wire of suitable size with proper clamping of approved make.4.0 sq. mm multi strand |
| 49 | Overhead water tank 1000 liter |
| 50 | Supply, installation, testing and commissioning of 'Silent Type' diesel generating set comprising with diesel engine air cooled, Synchronous alternator, AMF control panel single/three phase, acoustic enclosure, battery with charger and related accessories including PCC 1:2:4 platform, incoming cable 10 mtr, earthing Cu/GI plate 2No/2No, exhaust pipe 'B' class with insulation as per CPWD specification and CPCB - II NormsSupply, installation, testing and commissioning of diesel generating set three phase, air cooled with AMF control panel, 30 KVA, 415V. |
| 51 | Design, Drawing, fabrication, supply,erection and commissioning of Trestle assy/ Railing decking/Trash rack/Structural steel hoist bridge/ structural steel hoist supporting structure for monorail /Catwalk bridge for connecting spillway piers for all type of sluice with embedded parts consisting of columns, beams, bracings, stiffeners, ties, chequered plate covering, hand railing, ladder etc., with all other accessories for operating gates, other structure including cost of all materials, machinery, labour, tools and tackles, cutting,aligning, anchoring, welding, finishing, cleaning, applying two coats of zinc chromate red oxide primer and three coats of approved synthetic enamel paint etc., complete as per specifications and approved drawings , including packing & forwarding, transportation charges for structural steel components and other materials. Please Enable Macros to View BoQ information |