| 1 | Excavating over area n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc.and getting out any type of soil all as specified and directed. |
| 2 | All as per SI No. 01 here-in-above but exc 1.5m deep and n exc 3.0m deep. |
| 3 | All as per SI No. 01 here-in-above but exc 3.0 m deep and n exc 4.5 m deep. |
| 4 | Removing excavated material n. exc.50mtr and depositing where directed at a level n. exc. 1.5m above the starting point all as specified. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming, in layers not exc 25 cm complete all as specified and directed |
| 6 | M&L for PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in foudation, drain in soft loose soil an getting out all as specified and directed. |
| 7 | M&L, Cement concrete type C-2 1:3:6 using 20 mm graded crushed stone aggregate in surface channels and drains etc including necessary formwork. Complete all as specified and directed by Engr-in Charge. |
| 8 | M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in roof padding, lintels upto 1.5 m span,coping,fillets,bed plates,plinth courses,seismic bands and the like finished fair and even including necessary formwork complete all as specified . |
| 9 | M&L Brickwork with sub class ‘B’ (old size) bricks, straight or curved on plan exceeding 6 metre mean radius built in cement sand mortar 1:4 complete all as specified. |
| 10 | M&L for rendering 15 mm thick in CM 1:4 with on bricks masonry or concrete surfaces on fair faces of brick masonry, finished even and smooth without using extra cement complete all as specified and directed. |
| 11 | M&L for providing cement concrete type B 1:2:4 (20 mm graded aggregate) in RCC band,beam, cantilevers,lintel over 1.5 m span. Complete all as specified and directed. |
| 12 | M&L TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips and as specified and directed. |
| 13 | M & L TMT bars 5mm dia and over upto and including 10mm dia as in stirrups cut to length bent to shape required including cranking bending spirally for hooping for columns hooking end and binding with and incl mild steel wiere (annealed) not less than 0.9 mm dia or securing with clips. |
| 14 | M&L precast Reinforced cement concrete 1:2:4 Type B1 fixed in cm 1:4 in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces complete all as specified and directed. |
| 15 | M&L for loose filling with aggregate of broken bricks of gauge 80 to 150mm in Recharge pit etc complete all as specified |
| 16 | M&L for loose filling with gravel of broken stone or boulder gauge 40 mm to 80 mm in each layers n exc 15cm thick spreaded, levelled and rammed incl watering complete all as specified and directed. |
| 17 | M&L for loose pea gravel size of (12.5mm to 20mm ) as filter pack used in recharge pit complete all as specified and directed. |
| 18 | M&L for coarse Sand filling under recharge pit , complete all as specified and directed. |
| 19 | Drilling & development of borewell of size 300 mm dia by direct rotary method generally in accordance to IS 2800-1979 (revised & amended) in all kind of soil strata including electric logging keeping sufficient space for pea gravel packing including disposal of surplus soil within 100 mtr, well ramming & stabiliszation of materials & transportation of drilling rig & other T &P to site complete all specified & directed upto 12 m depth suitable for PVC pipes of dia as catered in this work, complete all as specified and directed. |
| 20 | Supply , assembly incl jointing, lowering slotted PVC pipe casing 200 mm dia incl fittings and fixtures,and surrounded filled by a mixture of gravel and coarse sand complete all as specified and directed. |
| 21 | Providing and fixing nylon filter mesh around slotted PVC casing/strainer pipe including binding with GI/SS wire complete all as specified and directed |
| 22 | S&F of PVC well cap of 200 mm dia of pipe at the top of casing pipe of bore well with locking arrangement complete all as spd and directed. |
| 23 | S&F of PVC bail plug of 200 mm dia of pipe at the bottom of casing pipe of bore well with fixing arrangement complete all as spd and directed. |
| 24 | Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410-0 or Fe 310-0 |
| 25 | Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 26 | Supply ,assembly incl jointing, lowering and fixing PVC pipe 200 mm dia including fittings and fixures complete all as specified and directed. |
| 27 | S&f for half round uPVC rain water gutter pipe of size 150-160mm nominal dia of approved make conforming to relevant IS specification fixed along roof slope eged incl neceassary fittings such as sockets ,bends stop ends ,drop ends couplers,gutter connector, central outlet, support etc as per requirements fixed with brand straps support at 1.2m interval as specified and directed |
| 28 | S&F for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 |
| 29 | S&F, for 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed. |
| 30 | S&F, for 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints,Fixed to wall, complete all as specified and directed |
| 31 | S & F 110 mm bore PVC Bends (SWR), complete all as specified and directed |
| 32 | S & F 110 mm bore PVC(SWR) junction single, (singleT), complete all as specified and directed |
| 33 | M&L for Concrete bed to drain pipes 200mm bore including packing under, and haunching against the sides of pipes complete surrounding after they are laid and tested, in cement concrete 1:4:8 type D2 complete all as specified and directed. |
| 34 | Preparation of new steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zink chrome primer, complete all as specified and directed by engr-in-charge. |
| 35 | S& F Galvanised, corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts or screws complete all as specified and directed |
| 36 | S& F for 0.63mm thick plain, galvanised, mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts or screws, complete all as specified and directed |
| 37 | Fixing only Galvanised, corrugated mild steel sheeting 0.63 mm thick with two corrugations side lap, fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts or screws complete including dismantling of existing plain or corrugated steel sheeting any gauge, thickness all as specified and directed |
| 38 | M & L clean sawn 20 mm thick with butt joint second class soft wood boarding, supplied & fixed with nails in any situation (except flooring and skirting) complete all as specified. |
| 39 | M & L clean sawn second class soft-wood timber in frame work scantlings complete all as specified. Please Enable Macros to View BoQ information |