| 1 | Receiving complaints from JE incharge lodged by the user/occupants of electrification nature, rectification of the fault as per the compaint lodged by the user onward kWH meter in respect of main distribution board having switch board, fused, MCB distribution board in sheet metal enclosure, point wiring fixture for light/fan /bell /light or power sockets, metal clad plug socket complete repair to extend by removing connections from the system, removing faults in (surface /concealed) wiring/ circuits, sunken boxes, Junction boxes, main switches, MCBs/DBs any type of utility light fittings, lamp holders, AC ceiling fan/exhaust fans and other connected fixtures of internal electrification including providing stores such as wires of appropriate size and conductor matching to existing one upto the light of 2 m, insulation tape, screws, nuts as per the site requirement to rectify the fault with regard to complaint lodged and refixing of fitting and fixture to their original position as dismentled complete all as directed at site to the entire satisfaction of Engineer -in- Charge.Notes : (i) Any copmplaint which is left out/unattendent for 2 days by the electrician by any reasons the same to be communicated to the JE incharge /AGE E/M with reason.(ii) New material/stores provided for completing the job shall be measured and paid for separetely under relevent items of sch 'A'.(iii) Contractor shall provide the all type of T & P to each electrician for attending the internal electric complaints. (iv) Contractor shall provide the complaint register and complaint slip serially numbered in duplicate as per sample. The rate of such items included in this items.(v) Any unattended complaints not done in specified time limit. The contractor shall penalty Rs. 200/- on each complaints per day.(vi) Docket shall be taken from MES complait cell at every morning at 09.00 AM by rep of Contractor and submitted at Complaint cell on next morning at 09.00 AM after satisfactorily completion on daily basis. |
| 2 | Supply only switch piano type 5 Amps one way AC 230 Volts. |
| 3 | Supply only switch piano type 5 Amps two way AC 230 Volts. |
| 4 | Supply only of bell push 5 Amps, AC 230 Volts. |
| 5 | Supply only switch socket combination outlet 3 pin 5 Amps flush type (Multi purpose) piano type AC 230 Volts. |
| 6 | Supply only switch/socket combination outlet 2 in 1, 3 pin 5 Amps and 15 Amp flush type (Multi purpose) piano type AC 230 Volts. |
| 7 | Supply only electronic dimmers, 450W, 250V flush type on the exiting phenolic laminated sheet etc. as reqd. |
| 8 | Supply only stepped type electronic fan regulator, flush type on the exiting phenolic laminated sheet etc. as reqd. |
| 9 | Supply only switch modular type 6 Amps one way AC 230 Volts. |
| 10 | Supply only switch modular type 16 Amps one way AC 230 Volts. |
| 11 | Supply only modular type bell push 6 Amps, AC 230 Volts. |
| 12 | Supply only modular type socket 6 Amps 2/3 pin combined, AC 230 Volts. |
| 13 | Supply only modular type socket 6/16 Amps 2/3 pin combined, AC 230 Volts. |
| 14 | Supply only modular type fan regulator, AC 230 Volts. |
| 15 | Supply only modular white cover plate with frame, 2 module. |
| 16 | Supply only modular white cover plate with frame, 4 module. |
| 17 | Supply only modular white cover plate with frame, 6 module. |
| 18 | Supply only modular white cover plate with frame, 8 module. |
| 19 | Supply only ceiling rose 65x50mm two to three terminal AC 230 Volts complete all as specified. |
| 20 | Supply only buzzer,AC, 230 Volts, single phase. |
| 21 | Supply only bell, ding dong, AC, 230 Volts, single phase. |
| 22 | Supply only bell multi music type AC, 230 Volts, single phase. |
| 23 | Supply only lamp holder insulated body with back plate batten/angle type for batten fittings. |
| 24 | Supply only sheet metal enclosures with plug socket single pole and neutral with two pin and earth plug and with one MCB of 20 Amps (SP) |
| 25 | Supply only of 45 Watt LED streetlight fitting luminaire, energy saving and environmental friendly long life LED street light made up of pressure die cast aluminium housing with high efficiency LED as lighting source and lens embedded PC cover having Bottom Opening seperate driver compartment with IP66 protection and impact resistance of IK08. |
| 26 | Supply only cable flexible PVC insulated twin core with copper conductor of size 23/0.0076 |
| 27 | Supply only cable flexible PVC insulated twin core with copper conductor of size 40/0.0076 |
| 28 | Supply only plug top 3 pin 5 Amps AC 230 Volts. |
| 29 | Supply only plug top 3 pin 15 Amps AC 230 Volts. |
| 30 | Supply only rigid non metalic PVC conduit including junction boxes terminal, tees bends, elbows reducers, bell mouth tube ends. |
| 31 | Supply only of 20 Watt inverter LED 6500 K (PRIDE PLUS) LED batten with square profile and polycarbonate channel Lithium ION battery with charging time 8hours-10 hours and back up time upto 4 hours. |
| 32 | Supply only of sheet metal enclosure (factory made) double door shutter type for distribution board (when MCBs are to be used) single pole and neutral 240 Volts 8 way with 200 Amps rated busbar. |
| 33 | All as per srl item No 32 here in beflore but 4 way SPN with 200 Amps rated bus bar. |
| 34 | All as per srl item No 32 here in beflore but 4 way TPN 415 Volts. |
| 35 | Supply only MCB SP, 6 to 32 Amps 10 kA single pole AC 230 Volts |
| 36 | Supply only MCB SPN 6 to 40 Amps 10 kA AC 230 Volts . |
| 37 | Supply only MCB TPN, 415 Volts, 63 Amps, 10 kA.. |
| 38 | Supply only PVC casing caping and fixing accessories . |
| 39 | Supply only smart extruded aluminium LED batten (4 ft) for surface application indoor decorative type with opal diffuser, IP 20 protection, 6500 K CCT, microwave sensor to save more energy and reduce the light intensity by 70% during non-occupancy. |
| 40 | Supply only LED light fitting 1x10W (2 Ft), 220V, AC, LED batten with square profile and polycarbonate channel, Lithium Ion battery with charging time 8-10 hours and back up time upto 4 hours. |
| 41 | Supply only LED luminaire 600x600mm, 36 Watt, 220 Volts AC recessed/ surface type fittings, epoxy powder coated CRCA sheet housing with electronic driver, connector block, etc. |
| 42 | Supply only LED lamp 9 Watt capacity. |
| 43 | Supply only invertor LED lamp 12 Watt capacity. |
| 44 | Taking down carefully aluminium point wiring (light, fan, socket, bell or power) complete including all fittings and fixtures, removing, materials from site and making good disturbed surfaces of wall, ceilings etc. |
| 45 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked including medium grade, PVC casing & caping and accessories surface on wall/roof/floor etc, ISI marked (IS-9537-1983 for PVC casing & caping and IS:3419:1976 for accessories), with mild steel/pressed steel sunken boxes (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with modular plate suitable for fixing Modular switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed at site Note :- Modular plates and Steel sunken box included in quotated rates (ii) Making good the disturbed surface to match with existing surface |
| 46 | All as per item No. 44.00 above but for one light controlled by two switches. |
| 47 | All as per item No. 44.00 above but 2/3 pin socket out let 5 Amps with 1.5 Sqmm on same board. |
| 48 | All as per item No. 44.00 above but for bell point. |
| 49 | All as per item No. 44.00 above but 2/3 pin socket out let 5 Amps with 1.5 Sqmm on independent board. |
| 50 | All as per item No. 44.00 above but for 2 in 1 three pin socket outlet 15/25 Amps on independent board with 4 Sqmm cable FRLS copper conductor multistranded including 4 sqmm PVC insulated and unsheathed FRLS copper conductor cable as earth continuity wire all as specified and directed. |
| 51 | S&F Modular switch,1 way 6A with \\"light / fan Marking\\" , 1 module, 230 Volts complete all as specified and directed. |
| 52 | S&F Modular 16A 1 Way Switch with Indicator, 1 module, 230 Volts complete all as specified and directed. |
| 53 | S&F Modular 6A Bell Push Switch with Indicator, 1 module, 230 Volts complete all as specified and directed. |
| 54 | S&F Modular Switch two way 6 Amps, 230 Volts complete all as specified and directed. |
| 55 | S&F Modular socket 6A, 3 Pin Round Socket with Shutter (ISI mark), 2 module, 230 Volts complete all as specified and directed. |
| 56 | S&F Modular socket 6A/16A 3 Pin Socket with Shutter (ISI Mark), 2 module, 230 Volts complete all as specified and directed. |
| 57 | S&F Modular fan regulator flush type 2 Module with 4 Step Regulator 100W (ISI mark), 230 Volts complete all as specified and directed. |
| 58 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of 2.5 Sqmm, earth continuity conductor of size 2.5 Sqmm to be drawn through and including PVC casing capping not less then 20mm dia medium Grade fixed on walls/roof/floors all as directed..Notes:- Two runs of 2.5 sqmm and onerun of 2.5 sqmm for earthing and one run of PVC casing/caping shall be measured as one unit. |
| 59 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 runs of 4 Sqmm, one run of earth continuity conductor of 4 Sqmm to be drawn through and including PVC casing capping not less then 32mm dia medium Grade fixed on walls/roof/floors all as directed.Notes:- Two runs of 4 sqmm and one run of 4 sqmm for earthing and one run of PVC casing capping shall be measured as one unit. |
| 60 | S&F Sheet metal enclosure factory made for DBs single pole and neutral double door 240 Volts 8 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed. |
| 61 | S&F Sheet metal enclosure factory made for DBs single pole and neutral double door 240 Volts 4 way with 200 Amps rated bus bar fixed on walls, including dressing and connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning and making good of wall, surfaces all as specified and directed. |
| 62 | S&F MCB, single pole and neutral, 240 Volts , 40-63 Amps all as specified and as directed. |
| 63 | S&F MCB, single pole and neutral, 240 Volts , 6-40 Amps all as specified and as directed. |
| 64 | Taking down/maintenance for parts of geysers of any capacity /make after disconnecting the wire from existing power point and refixing the same after replacement of heating element, thermostate, geyser assembly, PVC pipe & anchor bolts, etc. (if required) complete all as specified and directed.,Notes :- (i) Work shall be carried out at the site on routine basis. (ii) Spares (heating element, thermostate, ARV, NRV, PVC pipe, gasket and anchor bolts etc. will be measured and paid separately) |
| 65 | Supply only heating element tringle type 1500 Watt, complete all as specified and directed. |
| 66 | Supply only heating element cup type 2000 Watt, complete all as specified and directed. |
| 67 | Supply only themostate for geyser, complete all as specified and directed. |
| 68 | Taking down of ceiling fan/exhaust fan of any size /sweep after disconecting the wire from existing ceilling rose and refixing the same after repair/ rewinding, cleaning dust, oiling, greasing & hanging clamps (if required) complete including providing flexible twin core copper conductor 40/0.0076 stranded cord from ceilling rose to connection of fan upto 1 m length complete all as directed. |
| 69 | Dismantling of 1200 mm sweep ceiling fan, transporting the work shop for segregation of unserviceable parts, cutting and removing out copper winding, cleaning the armature, rewinding of fan armature with appropriate gauge of super enamelled copper wire with necessary insulating materials such as vertex paper, cotton tape, PVC insulation tape, Rotter soft etc varnishing with approved grade of insulation varnish and heating up, re-assembling the fan complete with replacement of unserviceable spares parts (spare parts will be measured & paid separately) including necessary lathe work for fixing of bush/bearing greasing the same with approved grade of grease, making all electrical connection and including S&F the following items (Split pin - 02 Nos, Connection block - 1 No and Insulation rubber bush. - 01 No) complete all as specified and directed. |
| 70 | Overhauling of ceiling fan of any make and sweep after opening and cleaning rotor bearing and stator properly and oiling/greasing of bearing/ bushes, reassembling the same, fixing and coonecting on its existing position and testing on completion all as specified and as directed including taking down. (Note- (i) Overhauling of ceiling fans will be carried out at AGE E/M Yard only.(ii) The spares required shall be measured and paid separately in the relevant items). |
| 71 | Taking down old universable rusted ceilling fan blades and providing new ceilling fan blades with fixing new screw as apporpriate shape /size suitable for ceilling fan of any make and 1200mm sweep size complete all as specified and directed. |
| 72 | Taking down old universable rusted ceilling fan blades and providing new ceilling fan blades with fixing new screw as apporpriate shape /size suitable for ceilling fan of any make and 1400mm sweep size size complete all as specified and directed. |
| 73 | Taking down old universable rusted exhaust fan blades and providing new exhaust fan blades with fixing new screw as apporpriate shape /size suitable for exhaust fan of any make and 380/450mm size of sweep complete all as specified and directed. |
| 74 | S&F starter and rotor assembly including body cell of ceiling fan for 1200 mm sweep complete including carbon brush, wire, etc all as specified and directed. |
| 75 | Painting of exhaut fan 225 to 450 mm sweep complete including fan blade down rod with synthetic enamelled paint of white tint including cleaning and removing dust and dirt and making smooth surface for painting including writing MES No complete all as specified. |
| 76 | S&F new gun mettal bush for various make of ceilling fan of size 1200 to 1400 mm sweep including taking down old gun metal bush complete all as specifide and as directed. |
| 77 | S&F bearing for ceiling fan (Bearing No.6201 Z Type). |
| 78 | S&F bearing for ceiling fan (Bearing No.6202 Z Type). |
| 79 | S&F bearing for ceiling fan (Bearing No.6203 Z Type). |
| 80 | S&F bearing for ceiling fan (Bearing No.6204 Z Type). |
| 81 | S&F new capocitor of 2.5 MFD 230 Volts with conector (capacitor holder with PVC clamps nuts) including taking out defective capacitor for ceilling fan complete all as specified as directed. |
| 82 | S&F new capocitor 4 MFD including taking out defective capacitor for exhaust fan complete all as specified as directed. |
| 83 | S&F brushless direct current (BLDC) ceiling fan 1200 mm sweep (ISI Marked) with super enamelled copper wire, white color, Class of insulation \\"B\\", 5 Satr rated, ISI marked, rated Voltage 230 Volt AC, 50 Hz , Rated power 26 Watt (+-) 10%, Rated speed 350 RPM (+-) 10%, power factor 0.9 at 5th speed, Air delivery 220 Cum/min (CMM) , service value 8.5 cum/min/W, operating temp 75 degree max, 3 Nos aluminium blades and thickness 1.1 mm (after painting), double ball bearing, speed control through regulator, Low Voltage starting i.e. 185 Volt minimum, Insulation resistance more than 2 mega ohm and lekage current 210 micro Amps Max includung connection rod as per existing length, writing MES Nos on ceiling fans complete all specified and directed. |
| 84 | M&L for Earthing complete with galvanised steel earth plate electrode 600x60x6.3 mm thickness burried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of earth plate not less than 1.5 m below normal ground level connected to and incl galvanised earth lead wire of 4.00mm dia by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4 type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25x25mm, excavation and earth work in any type of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire -mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical Plate No 3 of MES Sch 2009 (Part I) connected main switch board all as specified and testing on completion. |
| 85 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m deep and getting out in soft loose soil all as specified and directed |
| 86 | Returining, filling in including spreading, levelling watering and well ramming in layer not exce 25 cm, all as specified and directed |
| 87 | Removing excavated soil to a distance not exce 50 m and deposited where directed at a level not exceding 1.5 m abvoe the starting point all as specified and directed. |
| 88 | Taking out of centrifugal pump set from foundation after disconnection from motor and transportation to workshop, dismantling the pump for repair/ overhauling incluiding cleaning of all parts of pump assembly throughly, including machine work of pump shaft inorder to obtain smooth finish including necessary polishing etc and installing back including helium gasket sheet not less then 1mm thick complete all as specified and directed. Make: Kirloskar, DSM -65-32A (Note:- Spares as required shall be measure & paid seperately against the relevant items). |
| 89 | (a) S&F Casing Wear Ring- |
| 90 | (b) S&F shaft sleeve- |
| 91 | (c) S&F Inter Stage Ring- |
| 92 | (d) S&F Ball bearing DE SKF |
| 93 | (e) S&F Ball bearing NDE SKF |
| 94 | (f) S&F Bearing cartridge DE |
| 95 | (g) S&F Bearing cartridge NDE |
| 96 | (h) S&F split gland bush |
| 97 | Disconnecting electrically and disengaging the Monoblock pump set 3 phase 415 Vlots, 50 Cycles, 3 HP, 1440 RPM capacity, removing from foundations, overhauling thoroughly including complete varnishing and reinsulation replacement of DE /NDE bearings, greasing, reassembling the monoblock pump set, mounting on the foundations, testing and commissioning all as directed. (Note- Rewinding will be measure & paid seperately under relavant item of sch.) |
| 98 | Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Vlots, 50 Cycles and taking out to local workshop submersible induction motor 30 HP for repair purpose including complete cleaning, varnishing, insulation, replacement of DE/NDE bearings and greasing and including shifitng back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. (Note- Rewinding will be measure & paid seperately under relavant item of sch.) |
| 99 | M&L for Rewinding the motor with super enamelled copper winding wire with appropriate same gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paper applying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulations as directed. |
| 100 | Supply and laying 20 mm dia GI tubing medium grade with all fittings and fixed complete including taking down complete all as specified and directed. |
| 101 | Supply and laying 25 mm dia GI tubing medium grade with all fittings and fixed complete including taking down complete all as specified and directed. |
| 102 | Supply and laying 40 mm dia GI tubing medium grade with all fittings and fixed complete including taking down complete all as specified and directed. |
| 103 | S&F in repair 40 mm dia Gun metal Globe or Gate valve with iron wheel head, screwed both ends for iron pipe and fixed with required necessary GI fittings complete |
| 104 | S&F in repair 25 mm dia Gun metal Globe or Gate valve with iron wheel head, screwed both ends for iron pipe and fixed with required necessary GI fittings complete |
| 105 | S&F in repair 20 mm dia Gun metal Globe or Gate valve with iron wheel head, screwed both ends for iron pipe and fixed with required necessary GI fittings complete |
| 106 | Dismantling/taking out unserviceable sluice valve/NRV/Airrelease valves of size 100mm to 150mm bore dia by opening/cutting rusted nuts, bolts etc all as specified and directed. |
| 107 | S&F in repair 150 mm dia CI sluic valve both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.6 ISI marked complete all as specified and directed. |
| 108 | S&F 100 mm CI sluic valve (ISI marked) both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 complete all as specified and directed. |
| 109 | S&F 150 mm CI sluic valve (ISI marked) both ends flanged and drilled, bonnet wedge stuffing box. Gland trust plate, hand wheel made out of grey CI, complete valve confirming to IS 14846 and its fittings suitable for hydraulic test pressure of 15 Kg/sqcm PN 1.0 complete all as specified and directed. |
| 110 | S&F of non return valve flanged of class 1.6 PN, with flanged as per IS:5312 body ring -Bronze IS: 318 gaskit-natural rubber Flange drilling-IS: 1538 P 1.6 complete all as directed of size 100 mm completed all as specified and directed. |
| 111 | M&L for 50,000 gallons capcity draining water from OH reservoirs not exc. 21 m head/staging, and cleaning internal portion of tank (bottom and walls) by means of coir / wire brush etc. and wash the internal portion of tanks by using bleaching powder @ 25 grams per 1000 Ltrs of water after removing sludge and mud etc to a distance not exc 50 m and writing letters with white paint (date of cleaning and capcity of tank) on black painted surface of tanks all as directed.Note:- All safety eqpts and lights required for cleaning shall be arranged by the contrcator. |
| 112 | M&L for 50000 gallons capcity draining water from UG reservoirs, cleaning internal portion of tank (bottom and walls) by means coir / wire brush etc. and wash the internal portion of tanks by using bleaching powder @ 25 grams per 1000 Ltrs of water after removing sludge and mud etc to a distance not exc 50 m and writing letters with white paint (date of cleaning and capcity of tank) on black painted surface of tanks all as directed.Note: All safety eqpts and lights required for cleaning shall be arranged by the contrcator. |
| 113 | M&L for 25000 gallons capcity draining water from UG reservoirs, cleaning internal portion of tank (bottom and walls) by means coir / wire brush etc. and wash the internal portion of tanks by using bleaching powder @ 25 grams per 1000 Ltrs of water after removing sludge and mud etc to a distance not exc 50 m and writing letters with white paint (date of cleaning and capcity of tank) on black painted surface of tanks all as directed.Note: All safety eqpts and lights required for cleaning shall be arranged by the contrcator. |
| 114 | M&L for Dehydration of tranformer oil, obtained from transformers/Voltage stabilizer/OCBs etc. Dielctric strength shall not be less than 40 kV in 2.5 mm gap electrode after dehydration. Dehydration of transformer shall be carried out by using electrically operated dehydration machine and topping up/ replacement of unserviceable transformer oil complete all as directed. Note :- Filteration of transformer oil shall be off loaded position of transformer. Please Enable Macros to View BoQ information |
| 115 | M&L for Dehydration of tranformer oil, obtained from transformers/Voltage stabilizer/OCBs etc. Dielctric strength shall not be less than 40 kV in 2.5 mm gap electrode after dehydration. Dehydration of transformer shall be carried out by using electrically operated dehydration machine and topping up/ replacement of unserviceable transformer oil complete all as directed. Note :- Filteration of transformer oil shall be off loaded position of transformer. Please Enable Macros to View BoQ information |