| 1 | Material and labour for General servicing of 1.5/2.0 TR capacity window type AC after taking down from the existing position, transporting to workshop, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water, replace the unserviceable parts if any including re-fixing the AC in same/ other location and connecting, commissioning complete all as specified and directed. |
| 2 | Material and labour for General servicing of outdoor unit of 1.5/2.0 TR capacity split type AC after taking down from the existing position, transporting to workshop, clean internal parts including condensing coil, blower, fan motor with suitable liquid/ solvent, clean filter, washing with water using jet pump , replacing the unserviceable parts if any including re-fixing the AC in same/ other location and connecting, commissioning complete all as specified and directed. |
| 3 | All as per item No 2 here-in-before but Indoor unit of split type air conditioner 1.5/2.0 TR complete all as specified and directed. |
| 4 | All as per item No 2 here-in-before but deep freezer of capacity upto 420 Litres complete all as specified and directed. |
| 5 | All as per item No 2 here-in-before but refrigerator of capacity 165 Litres to 310 Litres complete all as specified and directed. |
| 6 | Material and labour for general servicing of 1.0/ 1.5/ 2.0 TR capacity window type AC after taking down from the existing position, clean internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water at same location, replace the unserviceable parts if any including re fixing the AC in same/ other location and connecting, commissioning complete all as specified and directed. |
| 7 | Material and labour for general servicing of outdoor unit of 1.5/2.0 TR capacity split type AC after taking down from the existing position, clean internal parts including condensing coil, blower, fan motor with suitable liquid/ solvent, clean filter, washing with water using jet pump , replacing the unserviceable parts if any including re-fixing the AC in same/ other location and connecting, commissioning complete all as specified and directed. |
| 8 | All as per item No 7 here-in-before but Indoor unit of Split type Air Conditioner 1.5/2.0 Ton complete all as specified and directed. |
| 9 | Material and labour for general servicing of 1.5/ 2.0 TR capacity inverter split type AC indoor Unit by using waterproof reusable service bag for washing and coil cleaning for internal parts, clean external cover with suitable liquid/ solvent, clean filter/ washing with water by using jet pump at same location, replace the unserviceable parts if any commissioning complete through OEM complete all as specified and directed. |
| 10 | All as per item No 9 here-in-before, but Outdoor unit of Inverter Split type Air Conditioner 1.5/2.0 Ton complete all as specified and directed. |
| 11 | Material and labour for leak testing of Window type Air Conditioner of capacity 1.0/1.5/2.0 TR including filling of nitrogen gas for pressure testing, finding leaks, Vacuuming the system, necessary brazing work, charging with suitable refrigerant gas of required quantity, testing for proper functioning complete all as specified and directed. |
| 12 | All as per item No 11 here-in-before but Split type Air Conditioner 1.5/2.0 Ton complete all as specified and directed. |
| 13 | Supply and fix in repairs of hermetically sealed compressor unit suitable for Window 1/1.5 Ton capacity in exchange of the existing unserviceable sealed compressor unit including connecting up complete all as specified and directed. |
| 14 | All as per item No 13 here-in-before but 2.0 TR complete all as specified and directed. |
| 15 | All as per item No 13 here-in-before but spilt AC of 1.5 TR complete all as specified and directed. |
| 16 | All as per item No 13 here-in-before but spilt AC of 2 TR complete all as specified and directed. |
| 17 | All as per item No 13 here-in-before but suitable for Refrigerator of capacity upto 310 Litres complete all as specified and directed. |
| 18 | All as per item No 13 here-in-before but suitable for Deep Freezer of capacity upto 420 Litres complete all as specified and directed. |
| 19 | Supply and fix Copper Condensing coil suitable for 1.5/2.0TR capacity Window type Air conditioner including necessary brazing, gas charging, leak testing, Vacuuming etc including taking down old unserviceable condensing coil complete all as specified and directed. |
| 20 | All as per item No 19 here-in-before but Outdoor unit of Split type Air Conditioner 1.5/2.0 Ton complete all as specified and directed. |
| 21 | Supply and fix in repair Running capacitor 100/120 MFD suitable for Window/Split type AC complete all as specified and directed. |
| 22 | All as per item No 21 here-in-before but 45/50 MFD complete all as specified and directed. |
| 23 | All as per item No 21 here-in-before but 36 MFD complete all as specified and directed. |
| 24 | All as per item No 21 here-in-before but 10 MFD complete all as specified and directed. |
| 25 | All as per item No 21 here-in-before but 8 MFD complete all as specified and directed. |
| 26 | Supply and fix in repair Capacitor 6 MFD, 240 Volt suitable for fan motor of Window / Split type AC complete all as specified and directed. |
| 27 | All as per item No 26 here-in-before but 4 MFD, 240 Volt complete all as specified and directed. |
| 28 | All as per item No 26 here-in-before but 2/2.5 MFD, 240 Volt complete all as specified and directed. |
| 29 | All as per item No 26 here-in-before but 1.5 MFD, 240 Volt complete all as specified and directed. |
| 30 | Material and labour for taking down the defective definite purpose magnetic contactor of the split/window AC’s of any make, and Supply and fixing of new contactor of 240 VAC. 30 Amps 50 Hz, and coil volt of 208/240V 50/60Hz and Testing complete all as specified and directed. |
| 31 | Supply and fix in repair swing motor suitable for window/split AC any type any make and capacity complete all as specified and directed. |
| 32 | Material and labour for taking down the damaged air filter set and supply and fix of new air filter set for split/window type AC’s of 1.5 / 2TR capacity complete all as specified and directed. |
| 33 | Material and labour for taking down the defective unserviceable starting relay and supply and fixing new rely suitable for 1.5/2TR Window / Split type AC’s and Testing complete all as specified and directed. |
| 34 | Material and labour for taking down the defective capillary tube set and supply and fixing new suitable capillary set for split type AC’s complete all as specified and directed. |
| 35 | Supply and fix in replacement of damaged drain connection with PVC flexible hose of dia 20mm ( length not less than 1 RM) with necessary clamps, nipple, coupling etc. for 1.0/1.5/2.0 TR capacity AC complete all as specified and as directed |
| 36 | Supply and fix in replacement of damaged drain connection with PVC pipe of dia 20mm necessary clamps, nipple, coupling etc. for 1.0/1.5/2.0 TR capacity of AC complete all as specified and as directed. |
| 37 | Supply and fix in repair MS anchor bolt/fast nut of size 8/10 mm (length of bolt not exceeding 100mm) for fixing of out door/indoor unit of Split AC including taking down old rusted and broken anchor bolt complete all as specified and as directed. |
| 38 | Supply and fix in repair brass flair nut of size 3/8\\"/5/8\\"/1/4\\"/1/2\\" or 3/4\\" length of bolt not exceeding 30mm including taking down old rusted and leaked flair nuts complete all as specified and as directed. |
| 39 | Supply and fix in repair fan bush suitable for indoor/out door fan motor of spit Ac and widow AC of any type and any make completed all as specifed and directed including taking down old u/s fan bush complete all as specified and directed. |
| 40 | Supply and fix in repair indoor fan motor , 240 Volt suitable for Window/split type AC of any capacity, make or model complete all as specified and directed. |
| 41 | Material and labour for maint of indoor fan motor including soldering of winding, testing , 240 Volt suitable for Window/split type AC of any capacity, make or model complete all as specified and directed. |
| 42 | Supply and fix in repair Fan motor 240 Volt suitable for outdoor unit of split type AC of any capacity, make or model complete all as specified and directed. |
| 43 | Material and labour for maint of Fan motor including soldering of winding, testing complete suitable for outdoor unit of split type AC of any capacity, make or model complete all as specified and directed. |
| 44 | Supply fix in repair fan motor 240 Volt suitable for outdoor unit of inverter type Split AC of any capacity, make or model complete all as specified and directed. |
| 45 | Material and labour for maint of fan motor including soldering of winding, testing complete suitable for outdoor unit of inverter type Split AC of any capacity, make or model complete all as specified and directed. |
| 46 | Supply fix in repair blower suitable for indoor unit of inverter type Split AC of any capacity, make or model complete all as specified and directed. |
| 47 | Supply fix in repair fan motor 240 Volt suitable for indoor unit of inverter type Split AC of any capacity, make or model complete all as specified and directed. |
| 48 | Material and labour for maint of fan motor including soldering of winding, testing complete suitable for indoor unit of inverter type Split AC of any capacity, make or model complete all as specified and directed. |
| 49 | Supply and fix in repair fan blade suitable for Window type AC of any capacity make or model complete all as specified and as directed. |
| 50 | Supply and fix in repair fan blade suitable for outdoor unit of Split type AC of any capacity make or model complete all as specified and as directed. |
| 51 | Supply and fix in repair non inverter type outdoor unit cabinate with copper condensing coil of split AC suitable for 1.5 Ton AC with aluminium fins complete all as specified and direced. |
| 52 | Supply and fix in repair non inverter type outdoor unit cabinate with copper condensing coil of split AC suitable for 2 Ton AC with aluminium fins complete all as specified and direced. |
| 53 | Supply and fix in repair copper tube 3/8\\" including nitrile rubber insulation for refrigerant line suitable for split type AC complete all as specified and directed. |
| 54 | All as per item No 53 here-in-before but copper tube of size 5/8\\" complete all as specified and as directed. |
| 55 | All as per item No 53 here-in-before but copper tube of size 3/4\\" complete all as specified and as directed. |
| 56 | All as per item No 53 here-in-before but copper tube of size 1/4\\" complete all as specified and as directed. |
| 57 | All as per item No 53 here-in-before but copper tube of size 1/2\\" complete all as specified and as directed. |
| 58 | Supply and fix in repair nitrile rubber insulation including white pvc electrical insulaion tape heavy duty, strong adhesive, weather resistant for refrigerant line suitable for split type AC complete all as specified and directed. |
| 59 | Supply and fill Refrigerant Gas R- 32 complete all as specified and directed. |
| 60 | Material and labour for welding of copper tube connecting both indoor unit to outdoor unit by using suitable brazing rod by the help of butane gas cylinder including cutting, jointing and testing complete all as specified and as directed as per site requirement |
| 61 | Supply and fix in repair cooling coil made out of copper tube suitable for indoor unit of split AC of any capacity complete all as specified and directed. |
| 62 | Supply and fix in repair indoor Printed Circuit Board including sensors and temperature digital display sensor suitable for LLYOD AC of following Models as follows including all connecting wires/ lugs and the model as per site requirement complete all as specified and directed.1.LS24VIHC2.LS24I38FI(G)3.LS24I32WSEL |
| 63 | Supply and fix in repair outdoor Printed Circuit Board including sensors suitable for LLYOD AC of following Models as follows including all connecting wires/ lugs and the model as per site requirement complete all as specified and directed.1.LS24VIHC2.LS24I38FI(G)3.LS24I32WSEL |
| 64 | Supply and fix in repair indoor Printed Circuit Board including sensors and temperature digital display sensor suitable for LLYOD AC of following Models as follows including all connecting wires/ lugs and the model as per site requirement complete all as specified and directed.1.LS18I35JA2.LS18FI3.LS18A4.LS18FHO5.LS18I31AF6.GLS18I5FWCBP7.LS18I32WSEL |
| 65 | Supply and fix in repair outdoor Printed Circuit Board including sensors suitable for LLYOD AC of following Models as follows including all connecting wires/ lugs and the model as per site requirement complete all as specified and directed.1.LS18I35JA2.LS18FI3.LS18A4.LS18FHO5.LS18I31AF6.GLS18I5FWCBP7.LS18I32WSEL |
| 66 | Supply and fix in repair indoor Printed Circuit Board including sensors and temperature digital display sensor suitable for LG split type AC Model all as specified, as per site requirement complete all as specified and directed. |
| 67 | Supply and fix in repair outdoor Printed Circuit Board including sensors and temperature digital display sensor suitable for LG split type AC of Model all as specified, as per site requirement complete all as specified and directed. |
| 68 | Supply and fix in repair indoor Printed Circuit Board including sensors and temperature digital display sensor suitable for LG split type AC of Model all as specified, as per site requirement complete all as specified and directed. |
| 69 | Supply and fix in repair outdoor Printed Circuit Board including sensors and temperature digital display sensor suitable for LG split type AC of Model all as specified, as per site requirement complete all as specified and directed. |
| 70 | Supply and fix in replacement outdoor Printed Circuit Board including sensors and temperature digital display sensor suitable for Voltas/Hitachi/Carrier/Blue Star split type AC of any model (invertor type) all as specified, as per site requirement complete all as specified and directed. |
| 71 | Supply and fix in replacement indoor Printed Circuit Board including sensors and temperature digital display sensor suitable for Voltas/Hitachi/Carrier/Blue Star split type AC of any model (invertor type) all as specified, as per site requirement complete all as specified and directed. |
| 72 | Supply and replacement Printed Circuit Board and temperature digital display sensor suitable for Split type/Window type of any capacity make or model complete all as specified and directed. |
| 73 | Supply and replacement Printed Circuit Board and temperature digital display sensor suitable for three phase Tower AC of any capacity make or model complete all as specified and directed. |
| 74 | Note from Ser Nos 62 to 73 :- The contractor should give a warrenty for 06 months on the PCB and no extra amount will be charged by the contractor on the failure of the PCB within 06 months complete all as specified and directed. |
| 75 | Material and labour for repair of Printed Circuit Board (indoor + outdoor ) for inverter type AC of any make and model complete all as specified and directed. |
| 76 | Supply and replace single phase preventer for Tower AC of any capacity make or model complete all as specified and directed. |
| 77 | Supply and fix in repair factory made MS bracket or Stand suitable for outdoor unit of split AC duly painted and grouted with fastnut/anchor on wall,including necessary PCC work, making surface matching with existing etc, complete all as specified and directed. |
| 78 | Supply and fill Refrigerant Gas-R-410a complete all as specified and directed. |
| 79 | Material and labour in repair to voltage stabilizer 5 KVA by cleaning of vents, tightening of electrical connections, checking of burnt marks/rust, repair of fan, repair of carbon brushes also checking and functioning of display panel of main stabilizing unit and testing on completion all as specified and as directed |
| 80 | All as per item No 78 here-in-before but of 4KVA complete all as specified and directed. |
| 81 | Material and labour in repair to voltage stabilizer 5 KVA by replacing PCB, sensing unit, power relay, connector piece and testing on completion all as specified and as directed |
| 82 | All as per item No 80 here-in-before but of 4KVA complete all as specified and directed. |
| 83 | Supply and fix in repair 3 Core multistranded Copper Conductor PVC insulated sheathed flexible cable of size 1.5 Sqmm complete all as specified and as directed |
| 84 | All as per item No 82 here-in-before but 4 Core, 1.5Sqmm complete all as specified and directed. |
| 85 | Material and labour for Sealed compressor unit suitable for 2.5/3 TR capacity 3 phase Tower AC including first filling of refrigerant gas, compressor oil etc. testing and commissioning , including taking down of old unserviceable one complete all as specified and directed. |
| 86 | Material and labour for servicing of condenser coil of Tower split AC 2.5/5 TR capacity, Cleaning / Pressure washing of choked condenser fins, tubes etc, with water soluble material including leak testing complete all as specified and directed. |
| 87 | Material and labour for detecting the burnt wiring of indoor and out door unit of split ac of capacity 1.5/2.0 ton also rectifing the same with the help of suitable size wire, connectors shouldering wherever required and making functional in all respect complete all as specified and directed. |
| 88 | Supply and fix in repair Fan motor suitable for outdoor unit of 3 phase tower AC of any capacity make or model complete all as specified and directed. |
| 89 | Supply and fix in repair Industrial type metallic 3 pin top 20 Amps 240 Volt complete all as specified and directed |
| 90 | Supply and fix in repair 15 Amps 240 Volt Plug top Heavy Duty complete all as specified and directed |
| 91 | Material and labour for sub main wiring on wall /ceiling with 2 runs of 4 Sqmm single core PVC insulated un sheathed multi stranded copper conductor FR cable 1100 Volt grade drawn through and including PVC conduit pipe/casing caping of medium grade not less than 20mm dia including PVC conduit/casing and caping specials and 1 run of 4 Sqmm cable single core 1100 Volt grade multi stranded copper conductor FR cable as earth continuity conductor and connecting with suitable size thimble including taking down of old one complete all as specified and as directedNote:- Three runs of 4 sqmm of sub main wire and one run of PVC conduit/casing and caping with accessories shall be measured as one unit |
| 92 | Supply and fix in repairs MCB protected socket 4 module 20A, metal base, PVC plate (white) color cover plate suitable for upto 2.0 Ton AC with 16A 3 pin top, 20 A SP MCB 16A Scoket duly concealed on the surface/wall including making all electrical connection complete all as specified and directed |
| 93 | Supply and fix in replacement of MCB SP 6 to 32 Amps \\"C\\" series 240 Volt, complete all as specified and directed. |
| 94 | Material and labour for spray painting single coat anti corrosive enamel paint to cover of window AC of 1.0/1.5/2.0 TR capacity complete all as specified and directed. |
| 95 | Material and labour for spray painting single coat anti corrosive enamel paint to outer unit of split AC 1/1.5/2 TR capacity complete all as specified and directed. |
| 96 | Material and labour for spray painting single coat anti corrosive enamel paint to cover of refrigerator for 310L capacity complete all as specified and directed. |
| 97 | Supply and replace non inverter indoor unit of split type AC of size 1.5/2TR of make by dismantling the old indoor and connecting up with existing outdoor unit including copper pipe and necessary brazing as per site requirement complete all as specified and directed. |
| 98 | Material and labour for disconnecting the unserviceable stabilizer of any capacity 230 volts, any make from site and servicing complete and refixing back with necessary nuts/bolts fixed on walls and connecting up with A/C's drilling as per site requirement complete all as specified and directed. |
| 99 | Supply and fill Refrigerant Gas-R-22 complete all as specified and directed. |
| 100 | Material and labour for dismantling, taking down after disconnection split AC of capacity 1.5/ 2.0TR from existing location including indoor/ outdoor units along with its pipes, connecting cables, clamps/ stands, water drain pipes etc including making good the surfaces to match with existing finishes in all respects and re-fixing at new location as directed with all accessories such as clamps, pipes, stand for outdoor unit including top up of refrigerant gas if required and making satisfactory working of AC unit in all respect complete all as specified and directed. Please Enable Macros to View BoQ information |
| 101 | Material and labour for dismantling, taking down after disconnection split AC of capacity 1.5/ 2.0TR from existing location including indoor/ outdoor units along with its pipes, connecting cables, clamps/ stands, water drain pipes etc including making good the surfaces to match with existing finishes in all respects and re-fixing at new location as directed with all accessories such as clamps, pipes, stand for outdoor unit including top up of refrigerant gas if required and making satisfactory working of AC unit in all respect complete all as specified and directed. Please Enable Macros to View BoQ information |