| 1 | Comprehensive maintenance of addressable fire alarm system installed at CNAI functionality of all components, cleaning all device , replacement of defective spares / components, comprising of following complete all as specified and directed :- Make : Morely. (a) Microprocessor based control Panel 2 Loop - 02 No. (b) Electronic siren - 02 Nos(d) Manual call points - 40 Nos.(e) Repeater Panels - 02 Nos.(f) 36 AH Battery - 04 Nos |
| 2 | Comprehensive maintenance of addressable fire alarm system installed at NAD functionality of all components, cleaning all device , replacement of defective spares / components, comprising of following complete all as specified and directed:- Make : Honeywell. (a) Microprocessor based control Panel 2 Loop - 02 No. (b) Electronic siren - 02 Nos(d) Manual call points - 60 Nos.(e) Repeater Panels - 02 Nos.(f) 36 AH Battery - 04 Nos |
| 3 | Comprehensive maintenance of addressable fire alarm system installed at WED functionality of all components, cleaning all device , replacement of defective spares / components, comprising of following complete all as specified and directed:- Make : Seimens. (a) Microprocessor based control Panel 2 Loop - 02 No. (b) Electronic siren - 02 Nos(d) Manual call points - 10 Nos.(e) Repeater Panels - 02 Nos.(f) 36 AH Battery - 02 Nos |
| 4 | All as per item Sl No 02 here-in-before but at TSK comprising of following complete all as specified and directed:-Make : Honeywell. (a) Microprocessor based control Panel 2 Loop - 01 No. (b) Electronic siren - 03 Nos(d) Manual call points - 20 Nos.(e) Repeater Panels - 02 Nos.(f) 36 AH Battery - 02 Nos Note for item Nos 1 to 4 :-a) Contractor Shall Maintain all the Documents and Produce to the Concerned Engineer in charge as and when required /preparation of RARb) Contractor shall give the Demo and training for all duty staffs about the fire alarm System. The unit rate quoted is deemed to be included for the Same(c)Spares required for replacement, shall be measured separately as 'Supply only' under respective items. |
| 5 | Supply and fix in repair addressable Manual call point resettable type complete all as specified and directed. |
| 6 | Supply and fix in repair Detectors Complying with and type certified to EN - 45 Addressable type multisensor smoke detector with heat and smoke combination with base with self built intelligence as per IS: 11360 complete all as specified and directed |
| 7 | Material and labour for FRLS cable Loop testing fault clearing checking and servicing complete all as specified and directed. |
| 8 | Supply and fix in repair Battery Maintenance free 12 Volt 36A/h complete all as specified and directed |
| 9 | Supply and fixing of water resistant fire alarm cable jointing kit suitable for multi core cable including connectors, heat shrink/cold shrink sleeves, sealing compound, insulation tapes, complete for straight/branch joint, ensuring IP68 protection complete all as specified and directed. |
| 10 | Supply and laying Fire Alarm Cable of 2 core 1.5 sqmm FRLS armoured copper conductor cable complete all as specified and directed |
| 11 | Material and labour for PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate for filling of road cuttings etc complete all as specified and directed |
| 12 | Supply and fix single phase surge protection device type 1 & 2 tested for lighting impulse current 10/350 micro second 50 ka for phase to neutral and 125 ka for neutral to earth, surge protection device tested for nominal discharge current 8/20 micro second 20 ka phase to neutral voltage protection level,<=1.4kv, encapsulated spark technology for line to neutral for type 1 and metal oxide for varistor for type 2 line to neutral. LED indication in line to neutral pole in type 1 and flag indication in type 2 line to neutral, response time for type 1 is less than 100 nano second and type 2 is less than 25 nano second, DIN Rail mounted complete all as specified and directed Please Enable Macros to View BoQ information |
| 13 | Supply and fix single phase surge protection device type 1 & 2 tested for lighting impulse current 10/350 micro second 50 ka for phase to neutral and 125 ka for neutral to earth, surge protection device tested for nominal discharge current 8/20 micro second 20 ka phase to neutral voltage protection level,<=1.4kv, encapsulated spark technology for line to neutral for type 1 and metal oxide for varistor for type 2 line to neutral. LED indication in line to neutral pole in type 1 and flag indication in type 2 line to neutral, response time for type 1 is less than 100 nano second and type 2 is less than 25 nano second, DIN Rail mounted complete all as specified and directed Please Enable Macros to View BoQ information |