| 1 | Dismantling/Taking down ACSR conductors of any type & size from existing LT pole & taking a side duly disconnecting all electrical connection complete all as specified & directed by Engr-in-Charge. |
| 2 | Dismantling/Taking down Cross arms of MS Channel or angle section etc complete all as specified & directed by Engr-in-Charge. |
| 3 | Dismantling Insulatotrs of any type & size from existing LT pole complete all as specified & directed by Engr-in-Charge. |
| 4 | Taking out unserviceable LT service connection cable of size up to 35 sqmm 3.5 core complete all as specified and directed. |
| 5 | Taking out old unserviceable LT cable of size 50 sqmm up to 150 sqmm 3.5 core complete all as specified and directed. |
| 6 | Excavating in trenches, in any type of soil not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in any type of soil complete all as specified and directed. |
| 7 | All as per item No 6.0, above but for each additional 1.5 m or part thereof in depth beyond the first 1.5 mtr. |
| 8 | M&L for Cement concrete 1:2:4 type B 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 9 | M&L for Cement concrete 1:4:8 type D 2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete complete all as specified and directed. |
| 10 | M&L for Cement concrete 1:3:6 type C 1 (using 20 mm graded stone aggregate) as in roof kerbs or pole couping of size 300x300 mm or chamfered on edges complete all as specified and directed. |
| 11 | Returning, filling in excavated approved soil, including spreading, leveling, watering and well ramming in layers not exceeding 25cm each complete all as specified and directed. |
| 12 | Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed. |
| 13 | M&L Sand cushioning with fine dry unwashed sand in trenches for cushioning of cables complete all as specified and directed. |
| 14 | M&L Old size sub class 'B' bricks, laid in trenches as cable covers complete all as specified and directed. |
| 15 | Supply and fixing in repairs Steel tubes, galvanised, light grade, ISI marked 40mm bore for protection of cable under floor, road and on wall complete all as specified and directed. |
| 16 | Supply and fixing in replacement for LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 17 | Supply and fixing in replacement for LED street light fitting 70 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 18 | Supply and fixing in replacemnt moulding compound Street light junction box of size 250 mm x 200 mm x 105mm complete with shock and rust proof, termite resistant, tamper proof , front openable type and including suitable provision for single phase, two wire cable (size upto 25 Sqmm 2 Core) incomming & outgoing loop -in loop connection and including one no. MCB SP 6 Amp including non metallic clamps and GI nut bolts and washers of suitable size and fixed on pole/wall complete all as specified and directed. |
| 19 | Supply and Fix, Three core pvc insulated copper cable with multistranded copper condutor of size 1.0 sqmm x three core, and drawing in to PVC Conduits & GI pipe bracket and connect to street light fittings complete all as specified and directed by Engr-in- Charge. |
| 20 | M&L for street light bracket made out of 40mm dia medium grade GI pipe of 1.2m length bent to required shape suitable for fixing street light / security light fitting on Steel tubular pole / RCC pole / building wall including two Nos clamps made out 30mm X 5mm flat with suitable nuts and bolts (clamp type - as per site requirement ) including two coats of aluminium paint over a coating of red oxide primer and Taking down of existing unserviceable rusted street light brackets with clamps, nuts and bolts etc, complete all as specified and directed. Please Enable Macros to View BoQ information |
| 21 | M&L for street light bracket made out of 40mm dia medium grade GI pipe of 1.2m length bent to required shape suitable for fixing street light / security light fitting on Steel tubular pole / RCC pole / building wall including two Nos clamps made out 30mm X 5mm flat with suitable nuts and bolts (clamp type - as per site requirement ) including two coats of aluminium paint over a coating of red oxide primer and Taking down of existing unserviceable rusted street light brackets with clamps, nuts and bolts etc, complete all as specified and directed. Please Enable Macros to View BoQ information |