| 1 | Attending internal/External electric complaints for maintenance/breakdown round the clock for maintenance, checking, fault finding ad rectification of fault in LT panels overhead HT/LT Lines, HT/LT underground cables, Transformers, switchgears internal electric faults, fans etc and carry out repairs and resume electric supply complete all as specified and directed Notes:- (a) Day to day complaint rectified by the electrician shall be written in complaint register and complaint document slip, rectified complaints only shall be measured and paid. Complaint attender shall have minimum qulification of ITI Electrician cum pumber having 2 years experiance of same nature of work is to be employed. (b) The spares required for rectification of faults shall be measured under relevent items. (c) All necessory tools shall be made available with the tecnician while executing the complaint. (d) All consumeables other than mentioned in schedules are deemed to be included in the rate quoted. (e) All kind of transport for the complaint attender/materials and mobile/cell charges are deeme to be included in the rate quoted. (f) All safety aspects are to be taken and if any accident/hazardous incidents happen during execution shall be the sole resposibility of the contractor. (g) Penalty of Rs 1000/- per complaint will be recovered from contractor if the complaint will not rectified within 24 hours. |
| 2 | Supply and fix in replacement switch piano, flush type single pole, one way 6 Amp, 230V complete all as specified and directed |
| 3 | Supply and fix in replacement switch piano, flush type single pole, two way 6 Amp complete all as specified and directed |
| 4 | Supply and fix in replacement Bell push, flush type, 6 amp complete all as specified and directed |
| 5 | Supply and fix in replacement socket outlet flush type, 6 A complete all as specified and directed |
| 6 | Supply and fix in replacement switch socket combination 2 in 1, 6 A flush type complete all as specified and directed |
| 7 | All as per Item No 6 here-in-before but 6A/16A, 5 in 1 complete all as specified and directed |
| 8 | Supply and fix plug top 3 pin 16 Amps, 240 volts, bakelite body, all as speified and directed. |
| 9 | Supply and fix replacement bell musical (ding dong type) , AC, 230 volts, single pole complete all as specified and as directed |
| 10 | Supply and fix in replacement stepped type electronic fan regulator flush type, hum proof, AC 240 V, 5 Step two module complete all as specified and directed. |
| 11 | Supply lamp holder, pin type, insulated body with back plate suitable for battern fittings AC, 240V, complete all as specified and directed |
| 12 | Supply LED tube light fitting of 20 watt, 230V, with extruded aluminium housing enhances safety, high quality PC Diffuser, easy to install Efficacy 110/125 lumen/watt complete all as specified and directed |
| 13 | Supply LED tube light fitting of 10 watt, extruded aluminium housing enhances safety, high quality PC diffuser, easy to install efficacy 100 lumen/watt complete all as specified and directed |
| 14 | Supply CIMFR certified flameproof LED battern ftg suitable for twin T8 tube of 20 watt. Recommended for Gas/Vapor group of llA & IIB and one 1 & 2, IP65 Protected complete all as specified and directed |
| 15 | Supply CIMFR certified flameproof LED battern ftg suitable for single T8 tube of 20 watt. Recommended for Gas/Vapor group of llA & IIB and one 1 & 2, IP65 Protected complete all as specified and directed |
| 16 | Supply CIMFR certified flameproof LED ftg 60 watt wellglass in die cast aluminium housing heat esistant toughened glass. Recommended fvor Gas/Vapor group of llA & IIB and one 1 & 2, IP65 Protected complete all as specified and directed |
| 17 | Supply and fix in replacement modular switch 1 way 6A,1 module, complete all as specified and directed |
| 18 | Supply and fix in replacement modular switch 2 way 6A,1 module complete all as specified and directed |
| 19 | Supply and fix in replacement modular bell push 6A 1 module complete all as specified and directed |
| 20 | Supply and fix in replacement modular socket, 6A - 2/3 pin combined 2 module complete all as specified and directed |
| 21 | Supply and fix in replacement modular socket 6A/16A - 2/3 pin combined 2 module complete all as specified and directed |
| 22 | Supply and fix in replacement modular fan step regulator, 120W - 2 module complete all as specified and directed |
| 23 | Supply and fix in replacement flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth complete all as specified and directed |
| 24 | Supply and fix in replacement switch flame proof rotary type with termination box inLM6, 16A, single pole 250V complete all as specified and directed |
| 25 | Supply and fix in replacement MCB SP 6 to 32 Amps, 220 volts, 10 KA, 'C' Series complete all as specified and directed |
| 26 | Supply and fix in replacement MCB SPN 25 to 32 Amps, 220 volts, 10 KA, 'C' Series complete all as specified and directed |
| 27 | Supply and fix in replacement MCB TPN 63 Amps, 415 volts, 10 KA, 'C' Series complete all as specified and directed |
| 28 | Supply and fix in replacement RCCB Double pole, 30mA, 25A complete all as specified and directed |
| 29 | Supply and fix in replacement RCCB 4 pole, 30mA, 63A complete all as specified and directed |
| 30 | Supply and fix in replacement LED 2 x 2 feet fitting, 36W, 230V,with CRCA Powder coated housing and high quality PC Diffuser, efficacy of 120 Lumen/watt , THD <10,L70 B50, , PF >0.95, with seperate driver module , complete with all accessories internally pre-wired and incl connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed |
| 31 | Supply and fix in replacement LED downlighter of 12 watt, 230V Sleek surface mounted pressure die cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver easy to install complete all as specified and directed |
| 32 | Supply and fix in replacement capacitor 2.5/3.15/4 mfd, 240 volts, AC suitable for fans etc. complete all as specified and directed |
| 33 | Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed |
| 34 | Material and labour for one light point wiring on surface/cieling/Trusses/concealed controlled by one switch with PVC single core sheathed copper conductor multistranded cables FRLS 1.5 sq. mm size drawn through and including PVC conduit of suitable size and all acessories, fire resitant, ISI Marked including 2 mm thick 60mm depth GI sheet pressed terminal box (recessed) with 3mm thick laminayed hylem sheet top cover including PVC single core unsheathed copper conductor multistranded cables FRLS 1.5 sq.as earth continuty conductor and makingn good the disturbed surfaces of walls/floors/ceiling etc complete all as specified and directed |
| 35 | All as per Item No 34 here-in-before but one ceiling fan point controlled by one switch complete all as specified and directed |
| 36 | All as per Item No 34 here-in-before but one exhaust fan point controlled by one switch complete all as specified and directed |
| 37 | All as per Item No 34 here-in-before but one 3 pin socket outlet 5 amps on the independent board complete all as specified and directed |
| 38 | All as per Item No 34 here-in-before but one 3 pin socket outlet 5 amps on the same board with other switches complete all as specified and directed |
| 39 | All as per Item No 34 here-in-before but one bell/buzzer point controlled by one push button on the same board with other switches or independent complete all as specified and directed |
| 40 | All as per Item No 34 here-in-before but for one light point controlled by two 2-way switches, with cables 1.5 sq. mm size complete all as specified and directed |
| 41 | All as per Item No 34 here-in-before but with cable 2.5 sqmm for one 3/5 pin socket outlet 15 amps on the independent board complete all as specified and directed |
| 42 | Material and labour For one light point wiring on surface/ceiling/Trusses/concealed controlled by one switch with PVC single core unsheathed copper conductor multistranded cables FRLS 1.5 sq. mm size drawn through and including stove enamelled steel conduit of suitable size and all acessaries, fire resitant, ISI Marked including 2 mm thick 60mm depth GI sheet pressed terminal box (recessed) with 3mm thick laminated hylem sheet top cover including PVC single core unsheathed copper conductor multistranded cables FRLS 1.5 sq.as earth continuty conductor and makingn good the disturbed surfaces of walls/floors/ceiling etc complete all as specified and directed |
| 43 | All as per Item No 42 here-in-before but with cable 4 sqmm for one 3/5 pin socket outlet 15 amps on the independent board complete all as specified and directed |
| 44 | Supply and fix in repair ceiling rose, 3 phase/PVC/polycarbonate, isolated body complete all as specified and directed |
| 45 | Material and labour for submain wiring with 2 runs of single core 1.5 sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS, ISI marked alongwith 1 runs of 1 sqmm multistranded insulated copper conductor cable as earth continuty conductor drawn through and including PVC conduit of suitable size on surface/ recessed as required complete all as specified and directedNote :- 2 Runs of PVC wires of 1.5 sqmm and 1 run of 1 sqmm earth wire and one run conduit will be measured as one unit. including taking down of old existing submain wiring. |
| 46 | Material and labour for submain wiring with 2 runs of single core 2.5 sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS, ISI marked alongwith 1 runs of 1.5 sqmm multistranded insulated copper conductor cable as earth continuty conductor drawn through and including PVC conduit of suitable size on surface/ recessed as required complete all as specified and directedNote :- 2 Runs of PVC wires of 2.5 sqmm and 1 run of 1.5 sqmm earth wire and one run conduit will be measured as one unit).including taking down of old existing submain wiring. |
| 47 | Material and labour for submain wiring with 2 runs of single core 4 sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS, ISI marked alongwith 1 runs of 2.5 sqmm multistranded insulated copper conductor cable as earth continuty conductor drawn through and including PVC conduit of suitable size on surface/ recessed as required complete all as specified and directed.Note :- 2 Runs of PVC wires of 4 sqmm and 1 run of 2.5 sqmm earth wire and one run conduit will be measured as one unit).including taking down of old existing submain wiring |
| 48 | Material and labour for submain wiring with 2 runs of single core 6 sqmm PVC insulated unsheathed multistranded copper conductor cable FRLS, ISI marked alongwith 1 runs of 4 sqmm multistranded insulated copper conductor cable as earth continuty conductor drawn through and including PVC conduit of suitable size on surface/ recessed as required complete all as specified and directedNote :- 2 Runs of PVC wires of 6 sqmm and 1 run of 4 sqmm earth wire and one run conduit will be measured as one unit) including taking down of old existing submain wiring. |
| 49 | All as per Item No 48 here-in-before but drawn through ERW Steel conduit complete all as specified and directed |
| 50 | Supply and fix in repair sheet metal enclosure for MCB DB Triple pole and neutral 4 ways, 415 volts with 200 Amps rated bus bar, double door complete all as specified and directed |
| 51 | Supply and fix in repair sheet metal enclosure for MCB DB Single pole and neutral 4 ways, 240 volts with 200 Amps rated bus bar, double door complete all as specified and directed |
| 52 | Supply and fix in repair sheet metal enclosure for MCB DB Single pole and neutral 8 ways, 240 volts with 200 Amps rated bus bar, double door complete all as specified and directed |
| 53 | Supply and fix in repair sheet metal enclosure for MCB DB Single pole and neutral 12 ways, 240 volts with 200 Amps rated bus bar, double door complete all as specified and directed |
| 54 | Supply and fix in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with single pole MCB 20A complete all as specified and directed |
| 55 | Material and labour in repair earthing complete with galvanised steel earth plate electrode 600 ×600 × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point including necessary earth work in any type of soil, PCC earth chamber made in PCC 1:3:6 type C1 using 20mm graded aggregate, common salt, charcoal, CI funnel, earth pit cover in RCC 1:2:4 type B1 using 20 mm graded aggregates, with 8mm CTD bars @ 100mm c/c in both ways, including necessary testing on completion including dismantling old one complete all as specified and as directed. Note:- The unit rate shall also include for excvation, earth work in hard/dense soil PCC 1:3:6 type C1 pit, RCC cover slab 300 x 300 x 50mm, GI funnel with 20mm dia watering pipe of 1.5 m long, wire mesh, 15mm dia light grade GI protection pipe for earth lead not less than 7.5 m etc. |
| 56 | Taking down fan, any size any make from various satellite area locations, for repair/replacement of defective parts and rehanging/refixing in its original location after reconditioning complete as specified and directed for Cieling fan of size 1200/1400 mm sweep, wall fan/Exhaust fan upto 450mm sweep complete all as specified and as directed.Note:- Items for reconditioning will be measured and paid separately under respective items of BOQ. |
| 57 | Material and labour for Painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and as directed. |
| 58 | All as per Item No 57 here-in-before but for wall fan/Exhaust fan upto 450 mm sweep complete all as specified and as directed. |
| 59 | Material and labour for removing the burnt out winding, cleaning slots, rewinding the motor with super enamelled copper wire of equivalent size to the original winding including warnishing, drying etc replacement of body screws, testing and commissioning on full load for 8 hours continous runing for Ceiling fan 1200/1400mm sweep complete all as specified and as directed. |
| 60 | All as per Item No 59 here-in-before but for wall fan/Exhaust fan/Pedestal fan upto 450 mm sweep complete all as specified and as directed. |
| 61 | Supply and replace ball bearing made out of high carbon steel as per existing suitable for Ceiling fan any type any size complete all as specified and as directed. |
| 62 | Supply and replace bush bearing made out of brass alloy as per existing suitable for Ceiling fan any type any size complete all as specified and as directed. |
| 63 | Taking down defective geyser of capacity 25/50 ltrs of any make from its existing position after disconnecting inlet/outlet water connection and opening of geyser for checking and repairing the defective parts, including testing the same after repairing, refixing the same on its original position and making all connections complete all as specified and as directed. |
| 64 | Supply and replace heating element 1.5/2 KW, 240 volts, AC any type with heat resistant rubber washer complete all as specified and as directed. |
| 65 | Supply and replace fusible plug with inernal or external threading for suitable for 25/50 ltrs capacity geysers any type complete all as specified and as directed. |
| 66 | Supply and replace non return valve made out of brass 15mm bore complete all as specified and as directed. |
| 67 | Material and labour for Painting of geysers complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and as directed. |
| 68 | Supply and replace inner assembly made out of brass with chromium plating, suitable for any type of geysers of 25/50 ltr capacity complete all as specified and as directed. |
| 69 | Material and labour for filling the glass wool between outer cover and inner tank of geysers 25/50 ltrs capacity including removing old one complete all as specified and as directed. |
| 70 | Supply and replace pressure/air release valve suitable to fix in inlet of geyser, made ut of brass mm bore complete all as specified and as directed. |
| 71 | Material and labour for disconnecting from position, servicing at same location including cleaning of interior parts and body with solvent materials, replacement of unserviceable spares/parts if required.necessory repairs, connecting, testing and commissioning of water cooler upto 120 ltrs, ozone based filter type hot and cold water cooler 85 ltrs capacity, refrigerator upto 310 ltrs cap complete all as specified and as directed. Note:- Spares will be measured and paid separately. |
| 72 | Supply and fix in repair for Factory reconditioned hermatically sealed compressor unit suitable for water cooler upto 120 ltrs, ozone based filter type hot and cold water cooler 85 ltrs, Refrigerator upto 310 ltrs for exchange of the existing unserviceable sealed compressor unit including initial charging of gas and oil complete all as specified and as directed. |
| 73 | Supply and fix in repair condensing coil made out of copper tube and aluminium fins suitable for Split AC upto 3 TR, water cooler upto 120 ltrs, Refrigerator upto 310 ltrs including necessory brazing , gas charging, leak testing, vaccumising etc complete all as specified and as directed. |
| 74 | Supply and fix in repair Evaporator coil made out of copper tube suitable for Refrigerator of capacity upto 310 ltrs complete all as specified and as directed. |
| 75 | Supply and fix in repair filter carbon suitable for Hot and Cold water cooler complete all as specified and as directed. |
| 76 | Supply and fix in repair main board suitable for Hot and Cold water cooler complete all as specified and as directed. |
| 77 | Supply and fix in repair Power supply PCB suitable for Hot and Cold water cooler complete all as specified and as directed. |
| 78 | Supply and fix in repair Solenoid valve suitable for Hot and Cold water cooler complete all as specified and as directed. |
| 79 | Supply and fix in repair Pressure pump suitable for Hot and Cold water cooler complete all as specified and as directed. |
| 80 | Supply and fix in repair heater coil suitable for Hot and Cold water cooler complete all as specified and as directed. |
| 81 | Supply and charging refrigerant gas upto required level including connected works such as pressure testing leak test with nitrogen before filling refrigerant gas complete for split AC upto 3 TR, complete all as specified and as directed. |
| 82 | Material and labour For servicing of Split AC indoor/outdoor unit upto 3 TR comprising through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts, rectifying electric wiring, defects etc to make the unit for smooth functioning complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 83 | Material and labour For servicing of Split AC indoor/outdoor unit upto 3 TR comprising through cleaning, lubricating of all moving parts, replacement of wornout screws, bolts, rectifying electric wiring, defects etc to make the unit for smooth functioning complete all as specified and as directed. Please Enable Macros to View BoQ information |