| 1 | M&L for earth work in excavation by mechanical means (Hydraulic excavator) means over areas (exceeding 30 cm in depth but not exc 1.5mtr, 1.5 m in width including getting out and disposal of all kind of soil excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-incharge |
| 2 | Returning, filling in, including spreading, leveling watering and well ramming in layers not exc 25cm in soft / loose soil complete all as specified & directed by Engr-in-Charge. |
| 3 | Excavation in post holes each not exc 0.5 cum, getting out soft/loose soil , returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exc 25cm, watering and removing surplush soil to a distance n exc 50m and making good surface complete all as directed by Engineer-in-charge and all as specified. |
| 4 | M&L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed. |
| 5 | M&L for Cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation and mass filling in drains complete all as specified and directed by Engr-in-Charge |
| 6 | M&L for PCC 1.2.4 type B2 using 40mm graded stone agreegate as in post holes for embedding the post all as specified and directed. Note : PCC shall be filled in alternate post and corner post only upto depth of post holes and measured accordingly for payment. |
| 7 | M&L for brickwork with subclass ‘B’ old size bricks in cement mortar 1:6 straight or curved on plan exc 6 mtr mean radius complete all as specified and directed by Engr-in-Charge |
| 8 | M&L Rendring 15mm thick on fair faces of brick work or concrete surfaces with water proof compound (LWPC will be measured and paid seperately) on wall in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed by Engr-in-Charge.Note :- Water proofing compound shall be measured and paid seperately under respective item. |
| 9 | Supply only integral liquid water proofing compound (ISI marked) complete all as specified and directed. |
| 10 | S&F, mild steel work such as angle iron as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets including all necessary drilling, bolting or rivetting etc and similar work confirming to Fe 290 Gd E-165. complete all as specified and as directed. |
| 11 | S&F for Mild steel screw bolts dia of Neck 11mm to 15mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,exc 5cm but n exc 10cm long compleete all as directed by Engr-in-charge. |
| 12 | S&F mild steel round bars as in tie bars of 10/12mm dia and over, fixed to fencing posts including cut to length, bent to shape, welding of bar at spots as directed and other similar works, conforming to Grade E-165 (Fe 290), complete, all as specified & directed.Note: Cost of cutting to length, bent to shape rquired & binding with MS wire is included in above rate. |
| 13 | M&L for compound girders and stanchions, lattice girders, aerial masts, staging for water tanks plain black sheet door shuters, door chowkats (frames), chullah hoods, water tanks water trough, grease trap cover fasterning for concrete, ducts, urinal troughs and funnels, etc. cut size edges beaded if directed, holes punched, including round headed screws, clout nails or rivets and fixed to wood or steel members, etc. and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc. to Fe 290 Gde-E-165 complete all as speified and directed. |
| 14 | Fixing only chain link MS galvanised fencing any size or type including line wires, any mesh, size and type to any type of standards, rails straining bolts, etc, complete all as specified and directed. |
| 15 | Supply only GI chanil link fencing 4mm dia, made of mild steel GI mesh 50 x 50mm, straining bolts etc. with 10/12mm dia round bars and flat iron, binding and jointing complete incl all necessary drilling, bolting or reveting etc. confirming to Fe 410 complete all as specified and directed.NOTE :- Round bars and FI shall be measured and paid separately. |
| 16 | Removing excavated material (soil) to a distance exc 50m but n exc. 250m and depositing where directed at a level n.exc 1.5m above or below the starting point complete all as specified and directed. |
| 17 | S&F, 150mm dia double wall corrugated class SN8, laid and jointed complete with collars etc. complete all as specified and directed. |
| 18 | M&L for providing and laying 100mm thick for precast sfrc manhole cover with frame including complete sides iron sheets (medium ) complying to the standard specification as mentioned in the IS-12592 BIS Standard minimum load bearing capacity 20 ton/ Sqm in square or rectangular shape (size as site requirement) complete all as specified and directed. |
| 19 | M&L for preparation of new or previously steel surfaces of any description, over 10 cm width or girth, not otherwise described and evenly applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 20 | M&L for painting to new or previously untreated steel surfaces of any description over 10cm in width or girth with two coats of synthetic enamel paint over a coat of zinc chromic primer including preparation of surfaces complete all as specified and directed. |
| 21 | M&L for two coats of synthetic enamel paint over a coat of red oxide primer on steel surface of any description n.exc. 10cm width or girth when unconnected with other painting or when painted in a different tint including preparation of new steel surfaces, complete all as specified and directed. |
| 22 | M&L for cutting into existing manholes for connecting new drain pipes, making good to pipes and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1, using 20mm graded stone aggregate, smooth finished and reforming benching as required for 150mm bore of pipe complete all as specified and directed. |
| 23 | M&L for PCC (1:2:4) TYPE B1 (using 20mm graded stone aggregate) as in coping and other similar bands incl weathering, slightly rounded or chamfered, angles and waste of form work throating as directed incl necessary form work complete all as specified and directed by Engr-in-Charge Please Enable Macros to View BoQ information |