| 1 | Excavation in trenches, not exceeding 1.5 m wide and n. exc 1.5 m in depth for laying of cable and getting out soft/ loose soil complete all as specified and as directed. |
| 2 | Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil complete all as specified and as directed. |
| 3 | Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level n.exc 1.5 m above the starting point complete all as specified and as directed. |
| 4 | M&L for spread dry fine river sand in trenches for cable protection including watering and consolidation complete all as specified and as directed.Note: Punned down thickness shall only be meausred and paid. |
| 5 | M & L for well burnt brick sub class B (using old size) laying in trenches perpendicular to axis of the cable for protection of electric cable complete all as specified and as directed. |
| 6 | Supply & laying GI tubing 'light grade' galvanised, with all fittings, fixed to walls, poles, ceilings complete for protection of cables of size 40 mm dia bore including taking out unsv GI tubing complete all as specified and as directed. Make:- Jindal/TATA/Prakash surya |
| 7 | Supply and laying or fixing or passing through pipe, LT XLPE insulated armured heavy duty cable 1100 volt grade ISI marked with aluminium conductor multi stranded of cross sectional area 10 sq mm 2 core including taking up/down old unsv cable complete all as specified and directed. |
| 8 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed with nominal cross sectional area 6 sq. mm 2 core including taking up/down old unsv cable complete all as specified and directed. Note:- (i) all connections are uniformally dressed and connected/ jointing of cable with suitable size of lugs. |
| 9 | Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed with nominal cross sectional area 4 sq. mm 2 core including taking up/down old unsv cable complete all as specified and directed. Note:- (i) all connections are uniformally dressed and connected/ jointing of cable with suitable size of lugs. |
| 10 | Supply and fixing in repairs two core FRLSH PVC insulated stranded aluminium conductor cable of size 2.5 sq mm, 1100 volts grade ISI marked complete all as specified and as directed. |
| 11 | Supply and fixing in replacement of Rigid non-metallic PVC conduit 20mm medium grade ISI marked fixed to the pole by using suitable size of clamps, nuts bolts and washers for drawing of service connection wire for electric installation as per IS 9537 part 3 complete all as specified and as directed. |
| 12 | Supply and fixing in repairs PVC street light junction boxes of size 380mmx225mmx140mm with front openable shutter and locking arrangement with one suitable size rating 6-32 Amps MCB, mounted on dwin rail, connectors including fixing to pole with MS flat iron clamp 25mm x 3mm size with nuts and bolts washers, complete all as specified and as directed. |
| 13 | Supply and fixing in repairs LED street light fitting 60 Watt, IP 66, 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant, corrosion resistant complete with driver, with and including brackets made out of 32 mm bore GI pipe,light grade of length not less than 1.50 mtr,45 degree bend to shape and fixed on pole with and including 2 Nos of FI clamps of 40x5 mm of suitable length fixed by means of bolts,nuts & washers etc including thermal management in multiple optics with IP 65/66 protection complete all as specified & as directed. |
| 14 | Supply and fixing in repairs LED street light fitting 70 Watt, IP 66, 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant, corrosion resistant complete with driver, with and including brackets made out of 32 mm bore GI pipe,light grade of length not less than 1.50 mtr,45 degree bend to shape and fixed on pole with and including 2 Nos of FI clamps of 40x5 mm of suitable length fixed by means of bolts,nuts & washers etc including thermal management in multiple optics with IP 65/66 protection complete all as specified & as directed. |
| 15 | Supply and fixing in repairs LED street light fitting 90 Watt, IP 66, 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant, corrosion resistant complete with driver, with and including brackets made out of 32 mm bore GI pipe,light grade of length not less than 1.50 mtr,45 degree bend to shape and fixed on pole with and including 2 Nos of FI clamps of 40x5 mm of suitable length fixed by means of bolts,nuts & washers etc including thermal management in multiple optics with IP 65/66 protection complete all as specified & as directed. |
| 16 | Supply and fixing in repairs LED street light fitting 35-45 Watt, IP 66, 230 V AC outdoor type with high pressure die cast aluminum housing and heat resistant, corrosion resistant complete with driver, with and including brackets made out of 32 mm bore GI pipe,light grade of length not less than 1.50 mtr,45 degree bend to shape and fixed on pole with and including 2 Nos of FI clamps of 40x5 mm of suitable length fixed by means of bolts,nuts & washers etc including thermal management in multiple optics with IP 65/66 protection complete all as specified & as directed. |
| 17 | Supply and fixing in replacement of unsv LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics, environmental friendly,corrosion resistant, and equipped with IP66 protection complete with driver and lamp suitable for tower lights as application including opening and fixing of nuts, bolts and washers on existing high mast/tower/wksp structure properly complete all as specified and as directed. |
| 18 | Supply and fixing in replacement of unsv LED flood light 200 watt 230 V AC outdoor type with thermal management in multiple optics, environmental friendly,corrosion resistant, and equipped with IP66 protection complete with driver and lamp suitable for tower lights as application including opening and fixing of nuts, bolts and washers on existing high mast/tower/wksp structure properly complete all as specified and as directed. |
| 19 | Material and labour for GI bracket for fixing of street light fitting , made out of 32 mm bore GI pipe,light grade of length not less than 1.50 mtr,45 degree bend to shape and fixed on pole with 2 Nos of FI clamps of 40x5 mm of suitable length fixed by means of bolts,nuts &washers including taking out old unsv bracket complete all as specified & as directed. |
| 20 | Supply and fixing in repairs MCB SP 6 to 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. |
| 21 | Supply and fixing in repairs MCB SPN 32 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed. |
| 22 | M & L for Steel tubular swaged poles Type 410-SP-31 (9 meter Long) including cast iron base plate finial tapper plug, bolts, cap, mild steel bolts, nuts and screws etc including applying two coats of black bituminous paint internally and externally up to planting depth and applying two coats of aluminium paints over and including a coat of aluminium primer (externally from top of PCC coping) conforming to IS 2713-1980 including dismantling of old steel pole complete all as specified and as directed. Note:Earth work and concrete foundation shall be measured and paid separately under relevant items of Sch 'A'. |
| 23 | M & L for PCC (1:3:6) type C-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete for pole foundation complete all as specified and directed. |
| 24 | M & L for PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) as in coping including necessary use & waste of form work complete all as specified and directed. |
| 25 | Supply and fixing in replacment of nature switch complete with timer, contactor, relays and suitable rating MCBs for incoming and out going in built in suitable IP 66 enclosure of three phase integrated models of capacity 8 KW to 10KW complete all as specified and directed. |
| 26 | Supply and fixing in replacment of nature switch complete with timer, contactor, relays and suitable rating MCBs for incoming and out going in built in suitable IP 66 enclosure of single phase integrated models of capacity 8 KW to 10KW complete all as specified and directed. Please Enable Macros to View BoQ information |