| 1 | Dismentalling of motor for vernishing, heating etc. complete in/c. reinstallation and making necessary electrical connection with main switch / starter with motor in/c trial run for 10 hrs in two spell complete as per direction of Engineer-in-charge. |
| 2 | Dismentaling of pump for over hauiling including greasing, gland packing, necessary repairs & reinstallation of the same including trial run for 10 hrs. in two spell complete as per direction of the Engineer-in-Charge.i) For L.I. |
| 3 | Supply & fitting fixing ball bearing of approved quality for pump required during overhauling.a) 6305 Ball bearing (TATA /SKF) |
| 4 | b) 6306 Ball bearing (TATA /SKF) |
| 5 | c) 6308 Ball bearing (TATA /SKF) |
| 6 | Providing & fitting fixing Shaft sleeve Bush of approved quality.i) Cast iron (C.I.) |
| 7 | ii) Stainless Steel (SS) |
| 8 | Providing & fitting fixing Shaft sleeve nut of approved quality.i) Cast iron (C.I.) |
| 9 | Providing & fitting fixing C.I coupling complete with nuts & bolts of approved quality.a) 150 mm dia. |
| 10 | Providing & fitting fixing PVC suction hose pipe overall thickness 5mm of best quality at site of work (Pankaj made) of approved quality.a) 150 mm dia. |
| 11 | Providing & fitting fixing MS hose clamp with nuts & bolts etc. complete at site of work of approved quality.a) 150 mm dia. |
| 12 | Providing & fitting fixing C.I tail piece of approved quality at site of work.a) 150 mm dia. |
| 13 | Providing & fitting fixing C.I foot valve of heavy duty at site of work of approved quality.a) 150 mm dia. |
| 14 | Providing & fitting fixing C.I foot valve spare parts of 125/150 mm dia at site of work of approved quality.a) C.I foot valve Weight. |
| 15 | b) C.I foot valve Ring. |
| 16 | c) C.I foot valve Net. |
| 17 | Providing & fitting fixing foot valve leather washer (6 mm thick) of heavy duty at site of work of approved quality.A) 150 mm dia. |
| 18 | Providing and fitting fixing of C.I. gland of approved quality.A) For L.I. |
| 19 | Providing & fitting fixing gland nut/Stag Nut 100mm long for gland of approved quality.A) For L.I. |
| 20 | Providing and fitting fixing of Full way valve (brass) 40 mm. dia. of approved quality. |
| 21 | Providing and fitting fixing 40 mm dia. following G.I. fittings of approved quality as per direction of Engg-in-Charge. a) Union Joint |
| 22 | b) Elbow |
| 23 | c) Bend |
| 24 | d) Tee |
| 25 | e) Socket |
| 26 | Providing & fixing 90° G.I. bend of approved quality at site of work. a) 150 mm. dia. |
| 27 | b) 125 mm. dia. |
| 28 | Providing & fitting fixing M.S flange (10mm thick) at site of work of approved quality. a) 150 mm. dia. |
| 29 | b) 125 mm. dia. |
| 30 | Providing & fitting fixing M.S flange (10mm thick) at site of work of approved quality. a) 150 mm. dia. |
| 31 | b) 125 mm dia |
| 32 | Providing and fitting fixing of full threaded nut and bolt of approved quality as per direction of the Engineer-in-charge. |
| 33 | Providing and laying of G.I. pipe with fittings complete as per direction of the Engineer-in-Charge.a) 40 mm. dia.(for priming line) |
| 34 | Repairing of OSCO starter including supplying & fixing of necessary spare parts as per direction of Engg-In-Charge. a) Stand finger |
| 35 | b) Gola Finger |
| 36 | c) Magnet Coil |
| 37 | Supplying & fitting fixing manually operated oil immerged starter of approved quality.a) 30 hp (OSCO/BCH Make) |
| 38 | Repairing of Main Switch in/c. supplying necessary Kit-cuts.a) 200 Amps |
| 39 | b) 63 Amps |
| 40 | Providing & fitting fixing Steel sheet enclosed switch Fuse unit (Suitable for DIN fuse) triple pole with Neutral Link (TPN) , 415/500 Volt, complete as per direction of Engineer-in-Charge. a) Current range 63 Amps. |
| 41 | b) Current range 100 Amps. |
| 42 | c) Current range 200 Amps. |
| 43 | Supplying & fitting fixing kit cut for main & sub-main swich (Male & female) as per direction of the Engineer in Charge. a) 63 Amps main switch |
| 44 | b) 200 Amps main switch |
| 45 | Supplying and greasing/applying of grease of approved quality as per direction of Engineer-in-charge. |
| 46 | Supplying and fitting fixing of asbestos rope of best quality as per direciton of Engineer-in-charge.a) 10 to 12 mm thick |
| 47 | Supplying & filling of Transformer Oil in the oil tank of manually operated oil immerged starter of approved quality. |
| 48 | Providing and fitting fixing electronic timer type ET 100 of approved quality as per direction of the Engineer-in-charge. |
| 49 | Repairing of pump- shaft by welding, polishing etc. complete as per direction of the Engineer-in-Charge. |
| 50 | Providing & fitting fixing Pump Shaft of approved quality. |
| 51 | Supplying & fitting fixing of PVC insulated Copper Wire with all electrical equipments including trial run etc. complete (ISI Marked) on the pannel board of approved quality.A) 7/16 Copper Wire.. |
| 52 | Supplying and fitting fixing AC Voltmeter (Moving Iron) on the panel board of approved quality.A) SMI-144, Range 0-400 to 0-500 |
| 53 | Supplying and fitting fixing AC Ammeter (Moving Iron) on the panel board of approved quality. A) SMI-144, Range 0-10A. |
| 54 | Supplying and fitting fixing of Indicator bulb (Flush type containig 3nos batton holder with bulb)) on the panel board of approved quality. |
| 55 | Providing & fitting fixing of pannel board of local teak wood for fitting & fixing of electrical items including 2 nos. MS angle post ( Size 50x50x6mm 2.80 Mtr. long) nuts& bolts etc. for errection of the same by 1 : 1.5 : 3 cement concreate casting (1feet x 1feet x 2feet) below the ground level and painting two or more coats of synthetic enamel paint on primer as per direction of Engg-in-Charge. a) Size 1.20 X 1.20 X 0.025 mtr. |
| 56 | Labour charge for reinstallation of all electrical equipments (dismentalled serviceable materials, if any additional/ replacement of electrical eqiupments required will be paid separtely) on the pannel board including trial run for 10 hrs in two spell complete as per direction of the Engineer-in Charge |
| 57 | Providing & fixing 200 Amps busbar of size 600 x 450 x 100 mm with 4 nos. copper strip of size 450 x 40 x 4 mm of approved quality. |
| 58 | Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per CPWD specification and direction of the Engineer - in - chargeA. External work.a) 150 mm dia. nominal bore. |
| 59 | Providing and fitting fixing of Moulded Case Circuit Breaker (MCCB) of different Thermal release range , 415 + V, 50Hz (L & T, BCH, ABB make) as per specification and direction of the Engineer-in-charge.i) 80-100 Amps |
| 60 | Providing and fixing C.I. non-return valve of approved quality as per of CPWD specification and direction of the Engineer - in - charge.a) 125 mm dia. Please Enable Macros to View BoQ information |