Tender for Renovation Work Of Govt. Upg. Middle School, Samdari, Bishunpur Block, District Gumla.

BOQ

Name of Work:- Renovation work of Govt. UPG. Middle School, Samdari, Bishunpur block, district Gumla.
Sl. No. Item Description
1Providing labour for cleaning, preparing plaster, and base for putty with brush of suitable type do all complete job as per direction of EI
2Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 Cement : 2 coarse sand (zone-III): 4 graded stone aggregate 20 mm nominal size)
4Dismantling R.C.C. work including - do- do- E/I.
5Reinforceemnt cement concrete work in beams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircase above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3
6Centering and shuttering including strutting, propping etc. and removal of form for Chajjas
7Reinforceemnt cement concrete work in beams, suspended floors, roofs having slope up to 15º landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral staircase above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3
8Providing and laying APP (Atactic polypropylene polymer) modified refabricated five layer 3mm thick water proofing membrane, black finished reinforced with non - woven polyester matt consisting of acoat of bitumen primer for bitumen membrane @ 0.40 litre/sqm by the same membrane manufacture of density at 25°C, 0.87- 0.89 kg/litre and viscocity 70-160 cps. Over the primer coat the layer of membrane shall be laid using Butane Torch and sealing all jointsetc, and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under :Jointstrength in longitunal and transverse direction at 23°c as 650/450N/5cm. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane mot less than 150°C. Coldflexibility shall be upto - 2°C When tested in accordance with ASTM,D - 5147. The laying of membrane shall be got done through theauthorised applicator of the manufacturer of membrane :3mm thick
9providing Tor steel reinforcement of 8, 10 mm and 12 mmmm dia bar as per approved design and drawing excluding carraige of M.S.bars to work site , cutting, bending, and binding with annealed wire with cost of wire removal of rust placing the rod in position all complete as per building specification and direction of E/I 8mm dia
1010mm Dia
11Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per specification and direction of E/I.
12Providing 19mm thick water proof cement plaster (1:3) with clean coarse sand of F.M. 1.5 with 5% cico or any other approved water proofing compound including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
13Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
14S/F M.S. grill made of 20 x 6mm M.S. flat as per approved design and drawing, properly fabricated with joints continous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction ofE/I. (Where materials is not supplied by the deptt.)
15Supplying fitting and fixing 20 gauge G.C.I. Sheet (Door & Window) gate on M.S.angle frame of size 60*60*6mm, including cost of fabrication providing necessary locking arrangements worth haskel and domny duly fixed in C.C. (1:2:4) blocks of required size,
16Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I.
17Providing applying plaster of paris putty of 1mm thickness over plastered surface to prepare the surface even and smooth copmlete .-do-do- as per sp. And direction of E/I.
18Providing two coat of oil bound distemper of approved shade and make over a primer coat of cement primer over new surface including preparing the plastered surface by rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding, washing floors and taxes all complete as per building specification and direction of E/I.
19Finishing wall with textured exterior paint of required shade New work ( Two or more coats applied @ 3.28ltr/10sqm) over and including primer coat of exterior primer applied @ 2.2./10sqm
20Finishing walls with Premium Acrylic Smooth exterior paint with of required shade: Old work(Two or more coats applied @ 1.67 ltr/ 10 sqm) on existing paint surface
21Provinding primer one coat of red lead paint of approved make over new steel surface including preparing the surface after cleaning, removing dirt, scales smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I. (Mode of measurment Area shall be multiplied by the co-efficient as indicated in building specificaton.)Multiplying Factor-1.2 (for each side) as per Table -1 [IS:1200]
22Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.Multiplying Factor-1.0 (for painting all over)
23Providing and laying double charge vitrified floor tiles in different sizes (thickness to be specified by the manufacturer ) with water absorption less than 0.08% and confirming to IS 4457:2007 of approved make in all colours and shades laid on 20mm thick cement mortar 1:4 (1 cement : 4 course sand) jointing with grey cement slurry @ 3.3kg/sqm including grouting the joints with white cement and matching pigment etc,complete.Size of tile 300x300x10mm
24Providing and laying 25mm thick kotah stone slab flooring of approved size texure and colour over 19mm thick base of lime mortar (1:1:1) (limeputty:surkhi:coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing to granolithic finish with approved quality of carborandum stone including cost of curing, taxes and royalty all complete as per building specification and direction of E/I.
25Providing 150mm wide brick drain in cement mortar (1:6) with as. 150mm clear depth and 250mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
26Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20mm nominal size ) over 75mm bad by dry brick ballast 40mm nominal size well rammend and consolidated and grouted with fine sand including finishing the top smooth.
27Carriage of materialsCement
28Steel
29Stone chips
30Electric workWiring for light /fan point / exhause fan point / call bell point with 1.5 sq.mm FRPVC inlsulated copper conductor single core cable in surface / recessede conduit with paino type switch phenolic laminated sheet suitable size M.S box insulated copper conductor.Group - A
31Wiring for light /power pluge with 2x4sq.mm FRPVC insulated copper conductor single core cable in surface / recessede PVC conduit along 1 No Sqmm FRPVC insulated copper conductor single core cable for loop earthing as required.
32Wiring for circuit/sub main wiring alongwith earth wire with the following sizes of PVC insulated, copper conductor, single core cable in surface/recessed PVC conduit as required2 x 2.5 sq.mm + 1 x 2.5 sq.mm earth wire
332 x 4.0 sq.mm + 1 x 4.0 sq.mm earth wire
342 x 6 sq.mm + 1 x 6 sq.mm earth wire
352 x 1.5 sq.mm + 1 x 1.5 sq.mm earth wire
36Supplying and fixing suitable sizes G.I/PVC box on surface or inrecess with phenolic laminated sheet cover in frong including providing and fixing 5 pin 5/6 amps socket outlet and 5/6 amps paino type switch connection painting etc as required.
37Supplying and fixing suitable size GI/PVC box of 121 mm x 173 mmx 48 mm /(6\\"x8\\") (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providng and fixing 6 pin 15/ amps paino type switch connection painting etc as required.
38S/F following rating double pole 240 volts isolator in the existing MCB DB complete with connection testing and commissoning etc as required.40 amps
3963 amp DP
40Providing and fixing following capacity DP/TP&N sheet metal/switchs disconnector fuse unit in existing metal board with rewireable type fuse including drilling holes in metal board making connection earthing the body etc as required.100 amp TP&N
41Providing and fixing following capacity bubar, chabmer with 4 strips of suitable sizes made of copper, heavy duty complete with all accessories including connections earthing the body100 Amp busbar chamber
42200 Amp busbar chamber
43S/F S.P MCB DB Supplying and fixing following way single pole netural sheet MCB distribution board 240 volts on surface / recess complete with tinned copper busbar netrual ibulsbar earth bar din bar detachable gland plate interconnections phosphatized and powder painted including earthing etc as required (But without MCB/RCCB/ Isolator)2 way single door (for campus light)
446 way single door
458 way single door
46S/F 6 amp to 32 amp ratting 240 volts \\"B\\" series MCB suitable for lighting and other loads of the following poles in the existing MCB DB complete with connection testing and commissiong as per required.
47S/F PVC/GI box fo following sizes on surface or in recess with suitable size of phenolic laminated sheet cover infront incliuding painting etc170 mm x 221 mm x 48 mm deep /(8\\"x10\\") for MCB
48S/F 2 pin 5 amp celling rose on the existing junction box/wooden block including connection etc
49Supplying and fixing batten / angle holder including connection etc as req.
50S/F following paino type switch /socket on the existing switch box/ cover including connection etc as req.Electronic step fan regulator, deluxe
5115/16 Watt LED Bulb
52S.I.T.C. of following rating recess/surface mounted LED round/ square shape down light luminarie with pressure die cast housing for single phase supply voltage. luminarie shall be confirmed to IS:10322 part-5/section-2 or IEC-62722 with all necessary accessories etc. complete as required18/20W LED Round Down light
53Supply, installation, testing and Commissioning of following size fan 3 Blades confirming to IS:374:2019 including wiring the down rods of standard for 230V 50 Hz, single phase supply etc. complete as required1200mm(48'') Ceiling Fan
54(a) 2 core 6 sq mm )for campus light, gate light, Toilet service connection)
55S/F/F 4'x3' size of panel board made of commercial board mounted on MS angle frame including the cost of grouting the same on wall all complete as req.
56WATER SUPPLY & SUBMERSIBLE PUMPProviding and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. E/I.
57Supply of G.I. pipes of Tata or any other ---------- all complete job as per direction of E/I.(i) 15mm dia
58(ii) 20mm dia
59(iv) 32mm dia
60Providing and fixing male ended 15mm dia brass bib cock ---------all complete as per direction of E/I.
61Providing and fixing brqass/C.I. stop cock of approved quality allcomplete as per specification and direction of E/I.(A)BRASS STOP COCK (a) 15mm dia.
62Supplying fitting and fixing of G.I. fitting -------------------- all complete as per direction of E/I.(A) Elbows. (a) 15mm dia
63(b) 20mm dia
64(d) 32mm dia
65(B) Tee plain. (a) 15mm dia
66(b) 20mm dia
67(d) 32mm dia
68(3) Reducing Socket (b) 20mm dia
69(d) 32mm dia
70(8) Socket plain.(a) 15mm dia
71(b) 20mm dia
72(d) 32mm dia
73Cutting chajja or cornice for laying G.I. pipes---------------- all complete direction of E/I.
74Making holes in walls for laying G.I. pipes---------------- all complete direction of E/I.(a) 125mm thick wall
75Supplying all materials, labours, tools & equipments for fitting and fixing 200 mm dia MS cap over casing pipe all complete job.
76Supplying 100mm dia submersible pump sets confirming to IS 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless pump shaft and polypropylene/ noryl impeller. - do - do - Pump shall have suitable outlet as per manufacturers design. Anti thrust stream lined nonreturn valve shall be provided with pump. 3 meter submersible copper conductor cable in single / double run shall be provided with each pump.Submersible pump Set of 2 HP Single Phase 150 mm dia (with Bronze impeller) up to 8 stages.
77(i) Cost towards Asbestos Suta (8 to 10 SWG) for supporting submersible pump (60 M) = 10Kg
78(ii) Solvent Cement
79Cost towards 2.5mm 3 core flat cable finolex or equivalent make.(i) Inside the bore well
80(ii) Upto Panel board inside the building to HYDT.
81Cost towards HDPE pipe to protect under ground cable from HYDT to panel board inside pump house 25mm dia HDPE roll pipe (Black) including inserting the cable inside the pipe.
82Crompton 2 Hp Starters control Panel
83ADD GST 18%
84LABOUR CESS 1% Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 55326871
AUTHORITY Government Departments
TENDER VALUE 24.99 Lakhs
LAST DATE 09-05-2026
Authority
Authority Name Rural Development Department
Work Description Tender for Renovation Work Of Govt. Upg. Middle School, Samdari, Bishunpur Block, District Gumla.
Basic Detail
Tender No RDD/SD/GUMLA/06/2026-27
Bidding Type Tender
Location
City Bishunpur
State Jharkhand
Key Dates
Publish Date 04 May 2026
Submission Date 09 May 2026
Open Date 11 May 2026
Finance
Tender Value 24.99 Lakhs
Tender Fee 5000
EMD 50000
Exemption Not Available
Document List
4cfd1c4e-6abd-49cb-826b-c43ffe7e2f25.html
BOQ_153425.xls
TenderDocument_06_02.pdf
Tendernotice_1 (8).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

May 04, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
May 09, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
May 11, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

4cfd1c4e-6abd-49cb-826b-c43ffe7e2f25.html

xls

BOQ_153425.xls

pdf

TenderDocument_06_02.pdf

pdf

Tendernotice_1 (8).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders