| 1 | Excavation for foundation / pipe trenches in earth soil of all types, sand, gravel & soft murum including removing the excavated material upto a distance of 50 m & lifts as below, stacking & spreading as directed, normal dewatering, preparing the bed for foundation & excluding the backfilling etc complete.a) Lift 0 to 1.50 M |
| 2 | Excavation for foundation / pipe trenches in hard murum and boulders including removing the excavated material upto a distance of 50 m & lifts as below, stacking & spreading as directed, normal dewatering, preparing the bed for foundation & excluding the backfilling etc complete.a) Lift 0 to 1.50 M. |
| 3 | Excavation for foundation / pipe trenches in soft rock by controlled blasting, including trimming & leveling the bed by chiselling where necessary & removing the excavated material & stacking it in measurable heaps within a distance of 50 m from the area & lifts as below, normal dewatering, excluding the backfilling etc complete.a) Lift 0 to 1.50 M. |
| 4 | Filling in plinth and floors / trenches murum bedding with approved murum from excavated materials from foundation in in 15 to 20 cm. layers including watering, compaction etc. complete. |
| 5 | Providing and supplying in standard lengthsPolyethelene Pipes, confirming to IS 4984 /14151 / 12786 /13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint /compression fitting joint or flanged joint excluding coupler/ specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays &rains, excluding GST levied by GI & GOM in all respect etc. complete.63 mm dia. HDPE Pipe (8 kg/cm) PE-100 |
| 6 | Lowering , laying & jointing with HDPE/ G.I. pipes and specials of following class and dia. including conveyance from stores to site of work, all labour, giving satisfacyory hydraulic test , etc. complete either underground or in verticle position , H. D. P. E./ M.D.P.E. pipes in proper position including all specials by compression fitting/ electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by Engineer-In-Charge.63 mm dia. HDPE Pipe (8 kg/cm) PE-100 |
| 7 | Providing double flanges Sluice Valve conferming IS 2906/14846 Incl worn gear arrangement as per test pressure stainless steel spindle, cap,inl. All taxes transportation etc. complete65 mm dia. S.V.( PN-1) |
| 8 | Lowering & laying and jointing in position following CIDF/Refluxe valve,Butterfly valve and Sluice valve incl. cost of all labour jointing material incl. nuts bolts and giving satisfactory hydraulic tesing etc complete.65 mm dia. S.V. (PN-1) |
| 9 | Providing and supplying Air valves as per IS-10845 and MJP’s standard specifications of approved mark and quality of following diameters including all taxes (Central and local), railway fright, inspection charges unloading from railway wagons, loading into truck, transportation upto departmental stores/ site, unloading and stacking etc. complete. |
| 10 | Lowering, Laying and fixing in proper alignment and position all types of C.I. Air valves as directed by Engineer in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc complete |
| 11 | Providing and fixing in position air valve shaft including providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providing PCC block of M-150 concrete 150 mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged joints wherever required and fixing of air valve over the shaft excluding cost of air valve and branch flanged air valve tee. etc. complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines (type design attached.) |
| 12 | Providing & constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding , B.B. masonry in C.M. 1:5 proportion, precast R.C.C. frame & cover etc. complete..As above of 60 x 45 cm internal size and depth upto0.9M with precast R.C.C. slab cover. |
| 13 | Providing and laying in situ Plain Cement concrete in proportion M-150 of trap metal for foundation & bedding, including out water manually, form work, capacity & caring etc…… complete... |
| 14 | Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard material in 15 cm layers with all leads and lifts including consolidation, surcharging, etc. complete. |
| 15 | Providing and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour , UPVC/MDPE Pipe of required length with or without Road crossing as described below, including cost of specials like Saddle/Clamp Saddle of suitable material, and diameter suitable for Distribution main, 15mm /20mm/ 25mmA) Household Connection without water meter (Comression Saddle+ISI Mark Ferrul)for HDPE & PVC pipe For MDPE/UPVC Pipe SerFor MDPE/UPVC Pipe Service Connection on Disribution main For 15 mm Service connection(With Road Crossing) For 15 mm Service connection |
| 16 | (Without Road Crossing) For 15 mm Service connection Please Enable Macros to View BoQ information |