| 1 | Providing ,fitting & alignment of Cast Iron Motor pulley for vacuum pump/Medical air compressor with cotter pin. |
| 2 | Providing ,fitting & alignment of Cast Iron pump pulley for vacuum pump/Medical air compressor with cotter pin. |
| 3 | Providing & fitting of V-Belt for Vacum Pump and Medical air compressor (Make Fenner/Hilton) |
| 4 | Providing and fitting of following dia and thickness medical gas copper pipe line, as per ASTM B8 19/IS 2501/BS 2874 including all standard procedures for laying jointing cutting, brazing polishing and providing of all necessary copper fittings (bends, tees etc). The pipe line route shall be as per site requirements or as instructed by site engineer. |
| 5 | 10 mm seamless tubing 0.9 mm thickness |
| 6 | 15 mm seamless tubing 0.9 mm thickness |
| 7 | 22 mm seamless tubing 0.9 mm thickness |
| 8 | 28 mm seamless tubing 0.9 mm thickness |
| 9 | 35 mm seamless tubing 1.2 mm thickness |
| 10 | 42 mm seamless tubing 1.2 mm thickness |
| 11 | Colour coating (Double coat) of Medical gas copper pipe lines with approved shades of following sizes. |
| 12 | 10 mm dia |
| 13 | 15 mm dia |
| 14 | 22 mm dia |
| 15 | 28 mm dia |
| 16 | 35 mm dia |
| 17 | 42 mm dia |
| 18 | Providing, fitting and testing of ball type main isolation valves along with complete fittings, the valves shall be brass metal and of reputed make. |
| 19 | 10 mm dia |
| 20 | 15 mm dia |
| 21 | 20 mm dia |
| 22 | 25 mm dia |
| 23 | 32 mm dia |
| 24 | 40 mm dia |
| 25 | Cleaning of Copper vacuum (Suction) pipes of following sizes using high pressure aimed at removing blockage due to blood clots and protein residues. The job includes cost of all tools and tackles used for cleaning: |
| 26 | 28mm dia |
| 27 | 22mm dia |
| 28 | 15mm dia |
| 29 | 10mm dia |
| 30 | Providing and fitting of Brass/Bronze Strainers |
| 31 | 10mm dia |
| 32 | 15mm dia |
| 33 | 22mm dia |
| 34 | 28mm dia |
| 35 | Providing & Fitting of Plastic make saddles to the Copper pipes of following sizes |
| 36 | 28mm dia |
| 37 | 22mm dia |
| 38 | 15mm dia |
| 39 | 10mm dia |
| 40 | Providing, fitting and testing of 2'' bronze vertical lift check valve of reputed make. |
| 41 | Providing, fitting & testing of self sealing valve assembly (front loaded double locking) including cover for oxygen supply/nitrous oxide supply/Medical air/Suction as per sample. |
| 42 | Providing, fitting & testing of self sealing valve assembly (front loaded double locking) excluding cover for oxygen supply/nitrous oxide/Medical/Suction as per sample. |
| 43 | Providing, fitting & testing of self sealing valve assembly (front loaded double locking) including cover for carbon dioxide with probe. |
| 44 | Providing, fitting & testing of BPC oxygen flow meter with humidifier bottles and BPS adapter connected to the self sealing valves of oxygen. |
| 45 | Providing, fitting, testing and commissioning of twin gauge regulator for Oxygen/Nitrous oxide. |
| 46 | Providing, fitting, testing and commissioning of twin gauge regulator for carbon dioxide. |
| 47 | Providing, fitting and testing of ward vacuum units (1000ml) complete with suction regulator and key plugs. |
| 48 | Providing fitting, testing and commissioning of ward vacuum units (2000ML) complete with suction regulator and key plugs. |
| 49 | Providing and fitting of copper tail pipe for oxygen or nitrous oxide. |
| 50 | Providing and fitting of flexible SS tail pipe for oxygen, nitrous oxide etc. |
| 51 | Providing and fitting of high pressure soft tubing for suction. |
| 52 | Providing and fitting of bed head service console 04 port not less than 24 inch in length. |
| 53 | Providing and fitting of bed head service console 05 port with socket. |
| 54 | Dismantling of medical gas bed head panel by way of cutting of existing pipes, dismantling of control valves and all the accessories. |
| 55 | 4 port bed head panel |
| 56 | 5 port bed head panel |
| 57 | Refitting of medical gas bed head panel. The job includes providing and fitting of dash fasteners, aligning the panels, refitting of copper pipe connections by way of copper /silver brazing and refitting of all the accessories likes control valves etc. |
| 58 | 4 port bed head panel |
| 59 | 5 port bed head panel |
| 60 | Repair to bed head console by way of replacement of damaged oxygen/vacuum/medical air port. Job includes cutting, brazing and material charges. |
| 61 | Repair to overhanging pendant by way of replacement of damaged oxygen/vacuum/medical air/nitrous oxide/AGSS port. Job includes cutting, brazing and material charges. |
| 62 | Dismantling of single gas outlet by way of cutting existing pipes, dismantling of control valves and all the accessories. |
| 63 | Refitting of single gas outlet. The job includes refitting of copper pipe connections by way of copper/silver brazing and refitting of all the accessories likes control valves etc. |
| 64 | Providing and fixing of rubber O-ring sets for medical gas outlets (Oxygen/Nitrous oxide/Medical Air/Vacuum) as per sample |
| 65 | Providing and fitting of probes for oxygen/suction/medical air/ Nitrous-oxide/CO² as per sample (Circular/hexagonal etc) |
| 66 | Providing and fitting of brass valves for oxygen, suction, medical air, Nitrous-oxide used in bed head consoles or otherwise as per the sample. |
| 67 | Repair to leak in the copper pipes used to carry flow of medical gases (Oxygen/Nitrous/Vacuum/Carbon dioxide/Medical air) from manifold to various parts of the hospital by way of cutting/brazing. Job includes material and labour charges |
| 68 | 28mm dia |
| 69 | 22mm dia |
| 70 | 15mm dia |
| 71 | 10mm dia |
| 72 | Providing and fitting of Pressure regulator valve (PRV) for medical air with brass fittings of following sizes |
| 73 | 28mm dia |
| 74 | 22mm dia |
| 75 | 15mm dia. |
| 76 | Providing and fitting of air pressure gauge dias 4\\" (0-10kg/cm²) |
| 77 | Providing and fitting of air pressure gauge dias 2\\" (0-10kg/cm²) |
| 78 | Providing and fitting of vaccum pressure gauge dias 4\\" (0-750mm Hg.) |
| 79 | Providing and fitting of pressure switch (Danfoss make) with differential presure range of 0.7 bar-4 bar. |
| 80 | Providing and testing of Oxiquant S portable oxygen purity analyser complete with sensor and integraded battery which can be replaced. (Envitec-Honeywell make) |
| 81 | Providing and testing of oxygen sensor for Oxiquant S Envitec portable oxygen purity analyser. |
| 82 | Providing and fitting of digital weight machine 200 kg with precision of 20 gram. |
| 83 | Providing and fitting of Air head/cylinder flange gasket for vacuum pump. |
| 84 | Providing and fitting of Piston ring set for vacuum pump/medical air compressor. |
| 85 | Top up oil (Servo press-100) for vacuum pumps and medical air compressors |
| 86 | Providing and fitting of complete valve assembly of vaccum pump (10 HP). |
| 87 | Providing and fitting of Inest Iwata 10 HP vacuum pump silencer. |
| 88 | Providing and fitting of Ingersoll rand 10 HP vacuum pump silencer. |
| 89 | Providing and fitting of 0.5 inch auto drain valve with timer and strainer. |
| 90 | Providing and fitting of 0.75 inch auto drain valve with timer and strainer. |
| 91 | Providing and fitting of 1.0 inch auto drain valve with timer and strainer. |
| 92 | Providing and fiiting of 2 inch copper elbow with wall thickness of at least 1.6mm (16 swg) |
| 93 | Providing of Medical oxygen/Nitrous/Carbon dioxide bulk cylinder single sided combination wrench. |
| 94 | Providing of Taparia (1172) 10 inch adjustable spanner. |
| 95 | Providing of Taparia (1173) 12 inch adjustable spanner. |
| 96 | Providing of Taparia (1272) 10 inch pipe wrench heavy duty. |
| 97 | Providing of Taparia (1273) 12 inch pipe wrench heavy duty. |
| 98 | Providing of Taparia (1275) 24 inch pipe wrench heavy duty. |
| 99 | Providing of taparia allen key set L type double sided (9 Keys). Siz- 1.5,2,2.5,3,4,5,6,8 & 10 mm. |
| 100 | Repair to vacuum pump/Medical air compressor foundation by way of first dismantling the vacuum pump/medical air compressor and base frame, then demolishing the old foundation and lying of new founadation block in RCC (1:2:4 ratio) and then fixing the new foundation bolts ( Minimum 2 feet long), base plate properly in RCC. The job includes all material, labour charges and curing. The vacuum pump/medical air comprssor should be then properly mounted on the base plate with proper alignment and testing. Rate is excluding of base frame. |
| 101 | Providing and fitting of new M.S base frame for vacuum pump/Medical air compressor as per existing dimensions of the base frame. The job includes RCC/civil work involved in the job. |
| 102 | Repair to base frame of vacuum pump/medical air compressor by way of welding of any cracked/damaged portion or complete replacement of damaged part. The job includes dismounting and reinstallation of the vaccum pump/medical air compressor on base frame with proper alignment & testing. |
| 103 | Providing and fitting of new foundation bolt assorted size for vacuum pump/medical air compressor.The job includes concrete/civil work involved in the job and dismounting/ reinstallation of the vaccum pump/medical air compressor on base frame with proper alignment & testing. Please Enable Macros to View BoQ information |