| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n exc 10 sq m on plan and n exc1.5 m in depth and getting out in soft/loose soil complete all as specified and directed. |
| 2 | M&L for Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft /loose soil complete all as specified and directed. |
| 3 | M&L for Cement concrete in foundations, filling and mass concrete type D2 1:4:8 (using 40mm graded stone aggregate) complete all as specified and directed. |
| 4 | M&L for M-25 (using 20mm graded stone aggregate) design mix for Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 5 | M&L for M-25 (20mm graded aggregate) design mix for Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 6 | M&L for M-25 (20mm graded aggregate) design mix for Columns, pillars, piers, posts and struts complete all as specified and directed. |
| 7 | Form work to sides of concrete foundation, footing , base of columns, raft and raft beams, sides and so fits of foundation and plinth beams and similar work, flat. complete all as specified and directed. |
| 8 | Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc, flat complete all as specified and directed. |
| 9 | Formwork to square sides of pillars, posts, struts, piers, columns and stanchions; square, rectangular or polygon complete all as specified and directed. |
| 10 | M&L for Brickwork with subclass ‘B’ old size bricks, straight or curved on plan exc 6m mean radius built in cement mortar 1:4 complete all as specified and directed. |
| 11 | M&L for TMT steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 12 | All as per Item No 11 bbove but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed. |
| 13 | Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed. |
| 14 | Demolition of reinforced cement Concrete of any description and in any position (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 15 | Removing excavated material n exc. 50m and depositing wheredirected at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 16 | M&L for Dholpur stone cladding gang saw cut 16-18 mm with machine cut edges, uniform colour of each stone size exceeding 0.5 sqm area fixed in cement mortar 1:4 with and including one number SS clamps (grade - 202) of flat-30mm X 2mm, 150mm long made to shape in each slab, making V groove at top and bottom of stone and drilling hole for hold fastener,polishing, rubbing & including silicon treatment complete all as specified and directed. |
| 17 | M&L for Red sand stone jali gang saw cut 16-18 mm with machine cut edges, uniform colour of each stone size not exceeding 0.5 sqm area fixed in cement mortar 1:4 with made to shape in each slab, using red stone patti at top and bottom of stone and Stone pillar for supporting of stone patti & Stone jali & including polishhing & rubbing complete all as specified & directed. |
| 18 | Taking down cement plaster of any description on brick or concrete surfaces of walls or ceiling etc incl. Raking out joints , hacking for key and scrubbing down with water complete all as specified and directed. |
| 19 | M&L for 15 mm thick rendering of cement mortar 1:6, on brick work or concrete surfaces on wall and finished the surface even and smooth complete all as specified and directed. |
| 20 | M&L for 15 mm thick rendering of cement mortar 1:4, on brick work or concrete surfaces on wall and finished the surface even and smooth complete all as specified and directed. |
| 21 | M&L for 5 mm thick rendering with cement mortar CM 1:3, on concrete surfaces as on ceiling, soffit of stair case, chhajjas facia etc including cement slurry etc finished the surface even and smooth complete all as specified and directed. |
| 22 | M & L Preparation of old decorative (plastered or unplaster surfaces) and applying two coat of white (lime) wash on wall surface complete all as specified and directed. |
| 23 | M & L Preparation of old decorative (plastered or unplaster surfaces) and applying two coat of white (lime) wash on ceiling surface complete all as specified and directed. |
| 24 | Material and labour for complete removal of existing treatment old decorated surface of walls and applying Two coats of cement based paint complete all as specified and directed. |
| 25 | Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removal complete all as specified and directed. |
| 26 | M&L for laying Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed. |
| 27 | Taking down chowkhats with shutter without taking off shutters from the frames area exc. 4.00 Sqm complete all as specified and directed. |
| 28 | S&F Steel rolling shutters, 1.25 mm thickness of lath with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type complete all as specified& directed. |
| 29 | M & L preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 30 | Material and labour, Gunniting to existing RCC Chajja, facia, parapet, beams, landings and similar RCC members after removing all loose concrete & preparations of surface, application of derusting chemical such as Dr Fixit Rust Remover or equivalent, welding additional bars/welded steel wire fabric if found necessary, priming reinforcement bars with a coat of zinc primer of coating not less than 40 micron, provision of bonding agent with bonding material like Dr Fixit bonding agent and repair to external RCC structure with slurry light and steel/ply form work and shortcrete concrete of mixed 1:3:1 (one part of cement, three part of coarse sand and one part of 10mm and down aggregate) of minimum 50mm thick incl plastering 10 mm thick in CM mortar 1:3 all as specified in IS 9012-1978 (all priming and bonding epoxy based paint shall be of Dr Fixit epoxy zinc primer or equivalent) etc complete all as specified and directed, as below:- Note(s) : 1. The rates include for necessary formwork and scafolding etc. 2. Reinforcement and welded steel wire fabric will be measured and paid separately. |
| 31 | Demolition of cement Concrete of any description and in any position including any type of roof treatment , PCC padding, lime concrete etc, complete all as specified and directed. Note: All demolished material / debries will be disposed off out side the Airforce station Subroto park with out any extra cost to the contractor. He should arrange dumping site to dispose off material. |
| 32 | Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc and including brushing neat cement slurry with 3 Kg/Sqm in roofs complete all as specified and directed. |
| 33 | M&L Cement concrete 1:3:6 type C1, (using 20 mm graded stone aggregate)mixed with water proofing compound pidi proof LW @ 200ml per 50Kg cement as per manufacturers instructions as in roof paddding, mass concrete finishing as required gradient cement concrete surface even and smooth without using extra cement complete all as spd and directed. |
| 34 | M & L APP based polymeric membrane minium weight 3 Kg/Sqm and minium 3 mm thick, reinforced with polyster non wove fabric (wt. not less than 150 gms/Sqm ) laid by torch forced application over a coat of bitumen 85/25 grade applied hot @ 1.20 Kg/Sqm laid over and including a priming coat using bituminious primer @ 0.40litre/ sqm and painting withaluminium paint at the top complete all as specied and directed. |
| 35 | M&L for cutting grooves in brick wall for inserting APP membrane and other works size of grooves 75mm wide and 65mm deep and shapping horizontal face of grooves and making good with cement mortar 1:3 or PCC 1:2:4 complete all as specified and directed. |
| 36 | M&L Cement concrete 1:2:4 type B0,(using 12.5 mm graded stone aggregate) as in roof kerbs or mud stops, on junction of parapet, coping etc cement concrete surface finished even and smooth without using extra cement complete all as specified and directed. |
| 37 | Supply only Liquid water proofing compound ISI marked. |
| 38 | Demolition of cement concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. |
| 39 | Dismantling of Stone slabs and tiles of any description or thickness in floors, aprons etc., removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 40 | M&L for Granite tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing Over and including 15mm thick Screed in CM 1:4 complete all as specified and directed. |
| 41 | M&L for 100 mm thick PCC 1:4:8 type D2 ( using 40mm graded stone aggregate) as in hard stand and sub base complete all as specified and directed. |
| 42 | M& L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade Using grey cement & no pigment complete all as specified and directed. |
| 43 | M&L for Tibba sand cushioning 40mm thick below paver block complete all as specified and directed. |
| 44 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement & no pigment over and including 15mm thick screed in CM 1:6 of in floors complete all as specified and directed. |
| 45 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 46 | Excavating in post holes (or similar holes) in soft soil each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, complete all as specified and directed. |
| 47 | Material & Labour for providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels, plates etc., including welding, grinding,buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories &stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement complete all as specified and directed. |
| 48 | S&F 10mm thick toughned glass as in hinged doors, partitions automatic doors and similar work including cutting to shape, drilling holes required complete all as specified and directed. |
| 49 | M&L Cement Concrete 1:2:4 Type B2 (using 40mm graded stone aggregate) as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars, boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 50 | M&L factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed. |
| 51 | Material and labour for preparation of newly untreated surfaces of kerb stone/concrete (plastered or unplastered) by brooming down etc. and applying two coats of synthetic enamel paint (white or tinted) over a coat of priming paint complete all as specified and as directed. |
| 52 | M&L for sand cushioning to under ground cable provided with layer of sand (8cm deep before laying the cable and 15cm deep after laying the cable i.e total 23) complete all as specified and directed. |
| 53 | M&L for brick laid in trenches for cable protection of burnt clay sub class 'B' complete laid dry flat complete all as specified and directed. |
| 54 | Taking out old unserviceable LT under ground cable any type from trenches, pipes & poles complete all as specified and directed. |
| 55 | Supply laying and testing of XLPE LT 1100 Volt Grade,armoured under ground cable size of 10 Sqmm 4 core with stranded aluminium conductor in trenches / passing trhrough pipes / on poles etc complete all as specified and directed. |
| 56 | M&L for galvanised steel tube, light grade with all fitting complete laid in trenches/ road / path / on pole of 40 mm bore complete all as specified and as directed. |
| 57 | Supply and fixing LED ornamental type post light made out of spun sheet aluminium main housing, post of aluminium die cast, front cover of clear acrylic, 40 Watt capacity (warm white), 240 Watt capacity , 240 Volts IP 65 including juction box complet all as specified and as directed by Engr-in-Charge. Make - Halonix cat Part No HLOPT-04-40-CW-01 or equivalent n all respect in Surya/Bajaj/Crompton/Philips |
| 58 | M&L point wiring with 1.5 Sq.mm (nominal aea) FRLSH PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing and capping complete with all fittings and accessories, fixed to walls/ceiling, including sunk type pressed steel terminal boxes 60mm deep, conforming to IS-5133 (Part-I) with 3 mm thick plastic laminated sheet cover (ISI marked) for mounting switches/regulator etc and including 1.50 Sqmm (nominal area) complete with 1100 volt grade PVC insulated unsheathed multistranded FRLHS PVC insulated and unsheathed multi stranded copper conductor cable 1100 volts grade, single core, earth continuity conductor connected to common earth dolly for one light/fan point controlled by one switch and making good disturbed surfaces of walls, floors etc complete all as specified and directed. |
| 59 | All as per item No 58 above but for one 3 pin socket outlet, 6 Amps on Independent board complete all as specified and directed. |
| 60 | All as per item No 58 above but with 2.5 Sqmm cable for Independent board one 3 pin 15 Amps socket outlet including single core 2.5 Sqmm PVC insulated copper conductor unsheathed 1100v grade IS-694 FRLS cable for continuous earth wire 2.5 Sqmm FRLS all as specified and directed by Engr-in-Charge (Only one 15 Amp point will be in one circuit) |
| 61 | Supply and fix switch piano, flush button single pole one way 5 Amp complete all as specified and as directed. |
| 62 | Supply and fix socket out let 3 pin 5 Amps, flush type complete all as specified and as directed |
| 63 | S&F switch piano 16 Amps flush type single pole one way suitable for 240 volt AC complete all as specified and directed. |
| 64 | S&F socket outlet 2 in 1, 5 pin 16 Amps flush type suitable for 240 volt AC complete all as specified and directed. |
| 65 | Supply and fixing of ceiling rose, surface bakelite, 65mm x50mm 2 or 3 terminals, PVC/Polycarbonate, isolated body fixed on PVC round block complete all as specified and directed. |
| 66 | Supply and fixing wall mounted LED batten extruded aluminium heat shrink provide for efficient heat dissipation and integrated electronic driver, 20 watt LED fitting with 100 lumen/watt, 6000k, 230 volts, diffuser optics, etc complete with all accessories, connecting up with twin core twisted flexible copper conductor cable from ceiling rose to fitting and testing complete all as specified and directed by Engr-in-Charge |
| 67 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Please Enable Macros to View BoQ information |
| 68 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. Please Enable Macros to View BoQ information |