| 1 | REPAIR TO TABLE DINING SIX PERSONS FD-273, 239 |
| 2 | Taking out unserviceable top of table dinning 6 persons, Supply & Fixing of new top of pre-laminated particle board 18 mm exterior grade with 4mm thick teakwood beading all round as per drg. |
| 3 | Taking out unserviceable leg, Supply & Fixing of new leg of first class teak wood, as per Drg. |
| 4 | Taking out unserviceable top long rail, Supply & Fixing of new top long rail of teak wood, as per Drg. |
| 5 | Taking out unserviceable top short rail, Supply & Fixing of new top short rail of teak wood, as per Drg. |
| 6 | S & F new bracket with 08 Nos new steel screws of suitable size bracket made out of 1st class hardwood (MP teak) of size 75mm x 75 mm x 25mm complete all as approved. Shown on Drg & as directed by Engr-in-Charge. |
| 7 | Taking out old unserviceable PVC shoes and Supply & Fixing of new PVC shoes with steel screw superior quality as approved by Engr-in - Charge. |
| 8 | Polishing of table dinning 6 persons with French polish after replacement of above components. |
| 9 | REPAIR TO TABLE PEG FD-236, 384, 277 |
| 10 | Taking out unserviceable top, Supply & Fixing of new top of pre- laminated particle board 18mm exterior grade BWR with all round 4 mm thick teak wood beading as per Drg. |
| 11 | Taking out unserviceable leg, Supply & Fixing of new leg of first class teak wood, as per Drg. |
| 12 | Taking out unserviceable top long rail, Supply & Fixing of new top long rail of first class teak wood, as per Drg. |
| 13 | Taking out unserviceable top Short rail, Supply & Fixing of new top short rail of first class teak wood, as per Drg. |
| 14 | Taking out old unserviceable PVC shoes, Supply & Fixing of new PVC shoes with steel screw superior quality as approved by Engr-in - charge. |
| 15 | Polishing of peg table with French polish after replacement of above components. |
| 16 | REPAIR TO TABLE 900 x 600 x 760mm With & W/O Drawer- FD-283,284,224 & 231 |
| 17 | Taking out unserviceable Top, Supply & Fixing of new top of pre-laminated particle board 18mm exterior grade BWR with all round 4mm thick teak wood beading as per Drg. |
| 18 | Taking out unserviceable leg, supply & fixing of new leg of first class teak wood, as per Drg. |
| 19 | Taking out unserviceable top long rail, supply & fixing of new top long rail of first class teak wood, as per Drg. |
| 20 | Taking out unserviceable top short rail, supply & fixing of new top short rail of first class teak wood, as per Drg. |
| 21 | Taking out unserviceable drawer, Supply & Fixing of new drawer of deodar wood except bottom which shall be of 6mm plywood commercial. Front portion of drawer shall be of teakwood. |
| 22 | Taking out unserviceable stiffener, supply & fixing of new \\"H\\" Type stiffener complete of first class hard wood teak as per Drg. |
| 23 | S & F new bracket with 08 Nos new steel screws of suitable size bracket made out of 1st class hardwood (MP teak) of size 75mm x 75 mm x 25mm complete all as approved. Shown on Drg & as directed by Engr-in - Charge. |
| 24 | Taking out old unserviceable PVC shoes and Supply & Fixing of new PVC shoes with steel screw superior quality as approved by Engr-in - Charge. |
| 25 | Polishing of table 900 x 600 x 760 mm with French polish after replacement of above components. |
| 26 | REPAIR TO TABLE CENTRE FD- 393 |
| 27 | Taking out unserviceable top of table centre, S&F of new top of pre- laminated particle board 18mm exterior grade BWR with all round 4mm thick teak wood beading as per Drg, |
| 28 | Taking out unserviceable leg, Supply & Fixing of new leg of 1st class teak wood, as per Drg. |
| 29 | Taking out unserviceable top long rail, Supply & Fixing of new top long rail of 1st class teak wood, as per Drg. |
| 30 | Taking out unserviceable top short rail, Supply & Fixing S&F of new top short rail of 1st class teak wood, as per Drg. |
| 31 | Taking out unserviceable stiffener, Supply & Fixing of new \\"H\\" Type stiffener complete of 1st class hard wood teak, as per Drg. |
| 32 | S&F new bracket with 08 Nos new steel screws of suitable size bracket made out of 1st class hardwood (MP teak) of size 75mm x 75mm x 25 mm complete all as approved. Shown on Drg & as directed by Engr-in - Charge. |
| 33 | Taking out old unserviceable PVC shoes and Supply & Fixing of new PVC shoes with steel screw superior quality as approved by Engr-in - Charge. |
| 34 | Polishing of table Centre with French polish after replacement of above components. |
| 35 | REPAIR TO TABLE BED SIDE FD/E-6/MAP/15 R |
| 36 | Taking out unserviceable top of table bed side, Supply & Fixing of new top made out of pre- laminated particle board 18 mm exterior grade as per Drg. |
| 37 | Taking out unserviceable left/right sides of table bed side, Supply & Fixing new right/left side of table bed side made out of pre-laminated particle board 18mm exterior grade. |
| 38 | Taking out unserviceable bottom of table bed side, Supply & Fixing of new bottom of made out of pre-laminated particle board 18mm exterior grade. |
| 39 | Taking out unserviceable partition of table bed side, Supply & Fixing of new partition of pre-laminated particle board 18mm exterior grade as per Drg. |
| 40 | Taking out unserviceable for back side ply, Supply & Fixing of new back side plywood 6mm thick as per Drg. |
| 41 | Taking out unserviceable MS Rod and MS Channel and S & F new Rod Made up of MS Square Pipe and MS Channel all as specified and directed by Engr-in Charge. |
| 42 | Polishing of table bed side after replacement of above components with French polish. |
| 43 | REPAIR TO TEAPOY FD -34(M) & 278 |
| 44 | Taking out unserviceable top, Supply & Fixing of new top of pre-laminated particle board 18 mm exterior grade with all round 4mm thick teak wood beading all round as per Drg complete all as specified & directed. |
| 45 | Taking out unserviceable leg, Supply & Fixing of new leg of 1st class teak wood, as per Drg complete all as specified and directed. |
| 46 | Taking out unserviceable top long rail, Supply & Fixing of new top long rail of 1st class teak wood, as per Drg complete all as specified and directed. |
| 47 | Taking out unserviceable top short rail, Supply & Fixing of new top short rail of 1st class teak wood, as per Drg complete all as specified and directed. |
| 48 | Taking out old unserviceable PVC shoes and Supply & Fixing of new PVC shoes with steel screw superior quality as approved by Engr-in - Charge. |
| 49 | Polishing of Teapoy with French polish after replacement of above components. |
| 50 | REPAIR TO BED PLYWOOD TOP FD-246, 245 |
| 51 | Taking out UNSV Head rest and S&F of new head rest as per Specification and as shown on Drg. |
| 52 | Taking out UNSV foot rest and S&F of new foot rest as per Specification and as shown on Drg. |
| 53 | Taking out old unserviceable plywood of head board and supply and fixing of new plywood 3mm teak shed in both side as per drg. |
| 54 | Taking out old unserviceable plywood of foot board and supply and fixing of new plywood 3mm teak shed in both side as per drg. |
| 55 | Taking out old UNSV long rail and Supply & Fix of new teak wood long rail as per Drg. |
| 56 | Taking out old UNSV Short rail and Supply & Fix of teak wood short rail as per Drg. |
| 57 | Taking out UNSV leg and Supply & Fix of new teak wood leg as per Drg. |
| 58 | Taking out UNSV Stiffener and Supply & Fix of new teak wood stiffener as per Drg. |
| 59 | Taking out UNSV plywood and Supply & Fix of new plywood 1980 x 900 x12mm BWR all as per specified and directed. Make- Kit Ply, Sainik or any make approved by Engr-in-charge. |
| 60 | Polishing of bed plywood Top with French polish wooden portion exposed to direct view after replacement of above components. |
| 61 | BOOK CASE FD No - 45 (M) & 247 |
| 62 | Taking out U/s top, S&F of new top made out of 18mm pre-laminated particle board exterior grade.compete all as specified & directed. |
| 63 | Taking out U/s right/left side of book case ,S&F of right/left side made out of pre-laminated pareticle board exterior grade complete all as specified and directed. |
| 64 | Taking out U/s bottom/ back side ,S&F new bottom/ back side made out of 18/19mm block bopard commercial type BWR complete all as specified & directed. |
| 65 | Taking out U/s shelves/partition of book case ,S&F new shelves/ partition made out of 18mm pre-laminated particle board exterior grade complete all as specified & directed. |
| 66 | Taking out U/s shutter ,S&F new shutter made out of pre-laminated particle board 18mm exterior grade with piano type hinges. Alluminiuym handle and catcher complete all as specified and directed. |
| 67 | Takingout U/s base frame, S& F new base frame made out of Ist class hardwood teak complete all as specified and directed. |
| 68 | Polishing of book case with french polish after replacement of above components all as specified and directed. |
| 69 | REPAIR TO TABLE 900 x 900 x 760 mm FD - 291,88(M) |
| 70 | Takingh out U/s top, S&F of new top of pre- laminated particle board 18mm exterior grade BWR with all round 4mm thiock teak wood beading asd per Drg, |
| 71 | Taking out UNSV leg, S&F of new leg of first cass teak wood , as per drg. |
| 72 | Taking out UNSV top rail, S&F of new top rail of first cass teak wood , as per drg. |
| 73 | S&F new bracket with 08 Nos new steel screws of suitable size bracket made out of 1st class hardwood (MP teak) of size 75mm x 75mm x 25 mm completeall as ap[proved. Shown on drg & as directed by Engr-in - Charge. |
| 74 | Taking out old UNSV PVC shoes and S&F of new PVC shoes with steel screew superior quality as approved by Engr-in - Charge. |
| 75 | Polishing of table 900 x 900 x 760mm with french polish after replacement of above components. |
| 76 | TABLE DRESING LADIES WITH MIRROR FD-32(M), 251, FD-378 |
| 77 | Taking out u/s top of table dressing ladies, S&F of new top made out of pre-laminated particle board 18 mm exterior grade as per Drg. |
| 78 | Taking out u/s bottom of table dressing ladies ,S&F of new bottom made out of 18/19mm block board commercial BWR as per Drg. |
| 79 | Taking out u/s legs of table dressing ladies ,S&F of new legs made out of first class teakwood. |
| 80 | Taking out u/s drawer ,S&F of new drawer made out of deodar wood except bottom.Bottom shall be 6mm plywood commercial.Front portion of drawer shall be made out of pre-laminated particle board 18mm with anodize copper plated knob. |
| 81 | Taking out u/s mirror with frame, S&F of new electro copper plated mirror 5mm with frame as per Drg. |
| 82 | Taking out UNSV/ broken sliding glass,S&F of new sliding glass asper Drg. |
| 83 | Taking out UNSV aluminium channel,S&F of new aluminium channel as per Drg. |
| 84 | Taking out back side plywood and S&F of new plkywood commercial 12 mm as per Drg. |
| 85 | Polishing of table dressing ladies after replacement of above components. |
| 86 | Table writing with Drawer [FD-249,275 & 33]Taking out Unserveceabletabke top from Table writing and Supply & fixed new table top made with 18 mm thick pre laminated MDF board exterior grade conforming to grade -1 & type III(PL MDF-13 Designation )as per IS 14587), One side teak face in Baverian beach shade and balancing white lamination on other side Make(as specified in particular specification )including 6 mm thick first class hard wood (MP Teak) edging all around the top complete as shown in drg & directed by Engineer-In-Charge. |
| 87 | Taking out Unserveceable/ damaged legs from table writing and Supply & Fixed new leg made of seasoned Shisham wood matching with the existing shape & sizes complete as specified & directed by Engineer-in-Charge. |
| 88 | Taking out Unserveceable/ damaged front or back rails from table writing and Supply & Fixed new rails made of seasoned Shisham wood to matching with the existing shape & sizes complete as specified & directed by Engineer-in-Charge. |
| 89 | Taking out damaged centre stiffener from table writing and Supply & Fixed new centre stiffeners made of seasoned Shisham wood to matching with the existing shape & sizes complete as specified & directed by Engineer-in-Charge. |
| 90 | Taking out Unserveceable/ damaged Shutter from table writing and Supply & Fixed new Shutter made of 18 mm thick Pre-laminated particle board Exterior BWR grade one side teak face of Make: Novapan/ Kit Ply sides covered with 4mm thick teak wooden or PVC beading all around the shutter including piano type hinges, 40 mm dia PVC knob & 6 lever steel lock with duplicate key of godrej patteren best quality complete as shown in drg & as directed by Engineer-in-Charge. |
| 91 | Taking out unserveceable/ damaged back plywood from box of table writing and Supply & Fixed new back made with 6mm thick plywood commercial Exterior grade BWR Make: Century/ Kit ply or Sudarshan complete as Shown on drg & directed by Engineer-in-Charge. |
| 92 | Taking out unserveceable/ damaged drawers from Table writing and Supply & Fixed new drawers made with 12mm thick seasoned sheasham wood except bottom & bottomg of drawers shall be of 6mm thick ply wood commercial type BWR grade Make: Century/ Kit Ply or Sudarshan Including PVC or wooden Knob complete as shown on drg & directed by Engineer-in-Charge. |
| 93 | Varnish polish to match with the existing complete to the Table writing including preparation of old wooden surface complete all as specified & directed by Engineer-in-Charge. |
| 94 | Supply of Sofa Set 3 Seater FD-281 DIMENSION:- Overall size shall be as shown in drg, all wood shall be first class well seasoned MP teak and free from knots and cracks, irrespective of what is shown on drg. The lenght of the three seater sofa is 1740 mm and widht shall be 725mm , height of the rear leg shall be 735mm and front leg shall be 550mm. Size of the front and rear legs shall be 75mm x 35mm and stiffner shall be 35mm x 35mm. A 12mm Ply as specified shall be there for the support of the cushion. The height of the the ply shall be 270mm. Front rail shall be 100mm x 35mm. All arms shall be 75mm x 35mm. 100mm foam 40D cushion with tapestry cloth as specified shall be present with the sofa set. All wood work and veneered surfaces shall be treated with french polish as specified. Timber shall be seasoned teakwood GDE-I. Pre-laminated MDF Board of Grade-I exterior quality as per IS:14587 shall be used. All joints and fixing shall be done by computer numerical control (CNC) in accordnace with the std workmanship/specification. 6mm th lipping shall be provided on all exposed edges of MDF duly treated with french polish as specified. Polish and Finish:- All exposed and hidden surfaces of wood shall be melamine polished with a high glossy finish. Rest all as shown on drg and as directed by Engg-In-Charge. |
| 95 | NOTE :- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs 7253.50 /- ] Please Enable Macros to View BoQ information |