| 1 | S&F in repairs LED with reflector for OT light of suitable wattage and colour in existing Shadowless OT light dome complete all as specified and directed. (Make :- Meditecindia/MDI or equivalent as approved by GE) |
| 2 | S&F in repairs digital controller suitable for existing shadowless OT light complete all as specified and directed. (Make :- Meditechindia/MDI or equivalent as approved by GE) |
| 3 | S&F in repairs SMPS suitable for existing OT Light complete all as specified and directed. (Make :-Meditechindia/MDI or equivalent as approved by GE) |
| 4 | S&F in repairs lid cover of suitable power for existing OT light complete all as specified and directed. (Make :- Meditechindia/MDI or equivalent as approved by GE) |
| 5 | S&F in repairs power cable of suitable size for existing OT lights complete all as specified and directed. (Make :-Meditechindia/MDI or equivalent as approved by GE) |
| 6 | S&F in repairs PCB in OT light complete all as specified and directed. (Make :-Meditechindia/MDI or equivalent as approved by GE) |
| 7 | S&F in repairs sterilizable Handle in OT light complete all as specified and directed. (Make :-Meditechindia/MDI or equivalent as approved by GE) |
| 8 | S&F in repairs LED 50 INNER 8 PORT CIRCUIT complete all as specified and directed. (Make :-HOSPIDIA LED 50 or equivalent as approved by GE) |
| 9 | M&L for comprehensive maint of shadhow less OT Light installed at old OT Command hospital (09 Nos) (Make :-HOSPIDIA LED 50) all as under complete all as specified and directed:- (a) Cleaning of light dome reflectors,handles and external housing, (b)Checking and tighting of all electrical connections and terminal, (c) functional inspection of arm, articulation, bearing, balancing and locking mechanism, (d) Lux level testing and alignment of light focus, (e) testing of control panel /monitor/dimmer and SMPS functioning. Note - (a)The contractor shall ensure that all 09 OT Light remain in fully functional, calibrated and reliable condition throughout the contract period. (b) Report card after complition of job shall be got signed by the users rep in token of completion of visit/job. |
| 10 | S&F in repairs digital controller box suitable for existing shadowless OT light complete all as specified and directed. (Make :-HOSPIDIA LED 50 or equivalent as approved by GE) |
| 11 | S&F in repairs SMPS suitable for existing OT Light complete all as specified and directed. (Make :-HOSPIDIA LED 50I or equivalent as approved by GE) |
| 12 | S&F in repairs of lid cover of suitable power for existing OT light complete all as specified and directed. (Make :- Make :-HOSPIDIA LED 50 or equivalent as approved by GE) |
| 13 | S&F in repairs of power cable of suitable size for vexisting OT lights complete all as specified and directed. (Make :-HOSPIDIA LED 50 or equivalent as approved by GE) |
| 14 | S&F in repairs PCB in OT light complete all as specified and directed. (Make :-HOSPIDIA LED 50 or equivalent as approved by GE) |
| 15 | S&F in repairs sterilizable Handle in OT light complete all as specified and directed. Make :-HOSPIDIA LED 50 or equivalent as approved by GE) |
| 16 | S&F in repairs LED 50 OUTER CONTROLLER CIRCUIT in OT light complete all as specified and directed. (Make :-HOSPIDIA LED 50 or equivalent as approved by GE) |
| 17 | S&F in repairs LED'S, 1 LED WITH LENS in OT light complete all as specified and directed. (Make :-HOSPIDIA LED 50 or equivalent as approved by GE) |
| 18 | S&F in repairs TOUCH SCREEN in OT light complete all as specified and directed. (Make :-HOSPIDIA LED 50 or equivalent as approved by GE) |
| 19 | S&F in repairs RECORDER in OT light complete all as specified and directed. (Make :-HOSPIDIA LED 50 or equivalent as approved by GE) |
| 20 | S&F in repairs LED 50 HOSPEDIA ARM in OT light complete all as specified and directed. (Make :-HOSPIDIA LED 50 or equivalent as approved by GE) |
| 21 | S&F in repairs Monitor 32 inches, view finity LED type duly configured with OT lights complete with 8 megal pixel resolution, 4k. All monitors to be installed on the OT wall/ ceilling pendent complete all as specified and directed. (Make: Samsung/LG/Sony or equivalent as approved by GE) |
| 22 | S&F in repairs Battery upto 20 KVA UPS EP 42-12 for OT light complete all as specified and directed. (Make :-Exide/Amaron or equivalent as approved by GE) |
| 23 | S&F in repairs Battery upto 120 KVA UPS EP100-12 for OT light complete all as specified and directed. (Make :-Exide/Amaron or equivalent as approved by GE) |
| 24 | M&L for Servicing of 120 KVA UPS EP100-12 for OT, ICU, CTVS & RADIATION, ONCOLOGY and RADIOLOGY including all minor components which are required for smooth fuctioning for backup power supply complete all as specified and directed. |
| 25 | S&F in repairs PCB upto 120 KVA KVA UPS for OT , ICU,CTVS & RADITION AND ONCO which reqired for smooth fuctioning for backup power supply complete all as specified and directed. |
| 26 | S&F in repairs and commisioning industrial type dehumidifier of capacity 50 Ltrs per day extraction capacity to control humidity from 40 to 70% RH, anti corrosive body, refrigerant 410A, rotary compressor complete all as specified and directed. |
| 27 | S&F in repairs Wiring (integrated) from OT\\"s to Head of Department and Confrence Room consisting of HDSDI Cables, OFC Cable, Multiviewers and SDI to HDMI Convertors as per requirement including all fittings and accessories complete all as specified and directed. |
| 28 | Taking down existing unsv scrub station in OT with all accessories complete all as specified and directed. |
| 29 | Supply, fixing & testing of double scrub station for OT made of stainless steel (grade SS 304) having minimum thickness 1.2 mm with digital controler including infrared senser for each tap of should have provision of following items including all connections and testing after installation complete all as specified and directed:- (i) finish type - Matte(ii) Front panel - Removable with key(iii) Operation - Foot pedal |
| 30 | S&F in repairs PCB in double scrub station complete all as specified and directed. |
| 31 | S&F in repairs display in double scrub station complete all as specified and directed. |
| 32 | Taking down existing unsv Bed Head Panel with all accessories complete all as specified and directed. |
| 33 | Supply, fixing & testing of Horizontal hospital Bed Head Panel not less than size of 1220MM X 300MM X 125MM length dual rail side extrusion, thikness 4.5 mm, Middle plate 5mm side cover 2mm, Epoxy powder coated, Gas outlet - BS/PB type out let, TECHNOMED type of probe DOUBLE LOCKING probe / adapter - ELECTYRO PLATED BRASS MATERIAL . IV POLE -SS GRADE 304 Dimension -350x8 mm, utility basket -SS as per HTM 2022 standard it should have provision of following items including all connections and testing after installation complete all as specified and directed:- (i) Oxygen Outlets - 02 Nos.(ii) Vaccume outlets - 01 No.(iii) 05/15 multisockets modular type with switch - 05 Nos.(iv) IV stand - 01 No. |
| 34 | Supply and installation of Air Curtains on entrance door with all wiring, accessories and mounting arrangement as under. The width of the air curtain to be 1800 mm. The wiring will be done using 2.5 Sq.mm x 3 core unarmoured cable from the provided power point including 16A, 3 pin plug top but not exceeding 2.5 mtr. in length. The Air Curtain will be mounted in a safe and sound manner using MS anchor fastener (minimum 3 Nos.) complete all specified and directed and neccessary fixing arrangement:-(i) Dimension (mm) -1800x230x212(ii) Maximum air velocity -21 m/s(iii) Noise lavel(db) -50-70 db (iv) Body Material: 304 Stainless Steel.(v) Width Size: 6 Feet(vi) No of Blowers: 6(vii) Nof of Motors : 3(viii) HP: 1.12(ix) Voltage: 220v / 50 HZ(x) No of Shafts: 1 Single + 1 Double(xi) Power Watage: 820 W(xii) Phase: Single(xiii) RPM (Max / Min): 2700/ 2100(xiv) Blower Material: ABS(xv) CFM : 1490(xvi) %Insect / Dust Rejection: 75%(xvii) Weight Kgs : 32 (Make- DOLPHY [Model No-DACN0018 of door opening size 70\\"x90\\" or equivalent as approved by GE) Please Enable Macros to View BoQ information |