| 1 | Supply, installation, testing and commissioning of pre-wired LED street light with pressure die cast housing and secondary lens delivering lumen level not less than 3600lumens and not more than 30W power, IP66 protection and 4kV inbuilt surge protection, THD<10%, PF>=0.95, 5700K pure white, conforms to IS 10322 Part 5 complete, including necessary interconnections and Earthing as required. (Approved makes: Bajaj/Philips/Havells/Crompton) |
| 2 | On Octagonal Pole |
| 3 | Supply and installation of a 3-meter-high Hot Dip Galvanized (HDG) octagonal pole made out of 3 mm thick hot rolled steel sheet having 130 mm bottom A/F and 70 mm top A/F, provided complete with a base plate of size 200 mm × 200 mm × 16 mm thick.The pole shall be erected on RCC foundation of mix 1:1.5:3 (1 cement : 1.5 coarse sand Zone-III : 3 graded stone aggregate of 20 mm nominal size) including necessary foundation bolts, excavation, cantering, shuttering, strutting, propping, placing in position and curing etc. complete.The work includes providing and placing Thermo-Mechanically Treated (TMT) reinforcement bars of grade Fe-500D or higher, including straightening, cutting, bending, binding and placing in position for RCC work up to plinth level, as per the pole manufacturer’s recommendations.The item shall also include:1. Excavation and refilling of foundation pit2. Finishing of foundation3. Providing and fixing 6A DP MCB inside suitable enclosure4. Providing 3 Core × 1.5 sq.mm flexible PVC insulated copper cable for interconnection between luminaire and MCB5. GI sheet for cable gland mounting6. Proper earthing arrangement7. Two coats of epoxy primer and epoxy paint (Aluminium grey)All necessary civil and electrical accessories to complete the work in all respects as per pole manufacturer’s recommendation and as directed by Engineer-in-Charge.(Approved makes: Bajaj/RR Ispat/Crompton; MCB: Legrand/L&T; Cable: Polycab/RR Kabel/Finolex/Havells) |
| 4 | With 0.5mtr long hot dip galvanized standard type Single armbracket made up of 40NB dia GI pipe suitable to mount on a pole having a top 70mm A/F. (Approved makes: Bajaj/RR Ispat/Crompton) |
| 5 | With 1mtr long hot dip galvanized standard type Double armbracket made up of 40NB dia GI pipe suitable to mount on a pole having a top 70mm A/F. (Approved makes: Bajaj/RR Ispat/Crompton) |
| 6 | Supply of FRLS XLPE power cable of 1.1 kV grade of the following sizes as required.(Approved makes: Polycab/RR Kabel/Finolex/Havells) |
| 7 | 3C x 4 sqmm Aluminum armored cable |
| 8 | Supplying and laying of the following size DWC HDPE pipe, ISI marked, along with all accessories like socket, bend, couplers, etc., conforming to IS 14930, Part II, complete with fitting and cutting, jointing, etc. Direct in-ground (75 cm below ground level), including excavation and refilling the trench, but excluding sand cushioning and protective covering, etc., complete as required. |
| 9 | 63 mm dia (OD-63 mm & ID-51 mm nominal) |
| 10 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of the following size in the existing RCC HUME/ METAL/DWC/ HDPE pipe as required. |
| 11 | Upto 35 sq. mm |
| 12 | Supplying and making end terminations with brass compression glands and copper lugs for the following sizes of PVC-insulated and PVC sheathed/XLPE Ar. Aluminium conductor cable of 1.1kV grade as required.Approved Makes: Dowells/Jainson/Raychem/Commet |
| 13 | 3core X 4 sq. mm(19mm) |
| 14 | Street Light Feeder PillarSupply, installation, testing and commissioning of Street light Feeder Pillar made of FRP/SMC material suitable for 433 Volt, 3 phase, 4 wire 50 HZ AC supply system having the necessary internal control wiring, earth bus, knockout for I/C & O/G cables, shrouding using SMC/FRP sheet, 100% weather proof-IP65 suitable floor mounting on concrete pedestal as required and as directed by Engineer in charge. The feeder pillar shall comprise the following: -Incoming100 A, 4P MCCB, 36 kA - 1No; Single pole (modular) RYB indicator with 2A TP MCB - 1 No.; Single pole (modular) two way change over switch- 250 V AC - 1NoBusbar4 Strip aluminium bus bar of 100A, 415 V capacity with heat shrinkable coloured sleeves, FRP mounting insulators, etc., for withstanding 36 kA fault - 1 setOutgoing40 A, 4P 'C' curve MCB - 2 nos.6 A, 2P 'C' curve MCB- 4 nos.Astronomical time switch suitable for 1 output per phase and suitable for single-phase supply-1no.25A 1NO modular contactor - 4NosMake: Weather-proof enclosure: Sintex - GSJB. 10069 (1000mm x 690mm x 300mm inside)Swithgears and accessories - L&T/ABB/Legrand Please Enable Macros to View BoQ information |