| 1 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm |
| 2 | Dismantling plain cement or lime concrete work including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 3 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 4 | Clearing Grass and Removal of Rubish Clearing grass and removal of rubbish up to a distance of 50 metres outside the periphery of the area. By Manual Means |
| 5 | Dismantling of guard rails Dismantling of guard rails by manual means and disposal of dismantled material with all lifts and up to a lead of 1000 metres, stacking serviceable materials and unserviceable materials separately |
| 6 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 8 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 9 | Providing and fixing at or near ground level precast cement concrete in kerbs, edgings etc. as per approved pattern and setting In position with cement mortar 1:3 (1 Cement : 3 coarse sand), including the cost of required centering, shuttering complete. |
| 10 | Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9\\"x4.5\\"x3\\") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 11 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20mm thick bed of cement mortar 1 : 4 (1 cement: 4 coarse sand). Light shade pigment using white cement |
| 12 | Providing and fixing 1 8 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1 : 4 (1 cement: 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red |
| 13 | Area of slab over 0.50 sqm |
| 14 | Providing edge moulding to 1 8 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work |
| 15 | Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete. |
| 16 | Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. |
| 17 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). |
| 18 | Supply at Site Well Decayed Farm Yard Manure |
| 19 | Supply at site of work well decayed farm yard manure, from any available source, approved by the engineer in charge including screening and stacking. |
| 20 | Spreading of Sludge Farm Yard Manure or/and good Earth |
| 21 | Spreading of sludge farm yard manure or/and good earth in required thickness (cost of sludge, farm yard manure or/and good earth to be paid for separately). |
| 22 | Grassing with ' Doobs' Grass Grassing with 'Doobs' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed. In rows 7.5 cm apart in either direction |
| 23 | Maintenance of Lawns with Fine Grassing for the First Year Maintenance of lawns with fine grassing for the first year including watering etc |
| 24 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concree, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with allk lifts and lead of 1000 metres By Mechanical means Cement Concrete Grade M-15 & M-20 |
| 25 | Removal of telephone/ Electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department , disposal with all lifts and up to a lead of 1000 metres and stacking the serviceable and unserviceable material separately |
| 26 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 27 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 28 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 29 | Painting Two Coats on New Concrete Surfaces (Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces) |
| 30 | Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 1000 metres, stacking serviceable and unserviceable materials separately By Manual means |
| 31 | Bituminous courses |
| 32 | Cable Duct Across the Road (Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (new construction), extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997, bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98 - 1997 and approved drawings.) |
| 33 | Single row for one utility service |
| 34 | Providing and applying tack coat with bitumen emulsion using emulsion pressure distributor at the rate of 0.30 kg per sqm on the prepared bituminous surface cleaned with mechanical broom. |
| 35 | Providing and laying bituminous macadam with higher capacity hot mix plant using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction. |
| 36 | Solar Powered Road Marker (Solar Stud) Supplying of Solar Raised Pavement Markers made of polycarbonate molded body with circular shape, solar powered, LED self illumination in active mode 360 degree illumination and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face in passive mode.The marker shall support a load of 20000 kg tested in accordance to ASTM D 4280.The marker should be resistant to dust and water ingress according to IP 65 standards and should withstand temperatures in the range of 0 C to 70 C. Color of lighting could be provided in red or yellow (amber) as per requirement and typical frequency of blinkikng in 1 Hz.There should be current losses of less than 20 microamperes at 2.4 V in sleepcharging mode to enhace the life of the marker and a full charge should provide for a minimum autonomy of 50 hours.The height, width and length of the marker shall not be less than 10mmx100mmx100 mm. Also, the surface diameter of the marker shall not be less than 100 mm respectively.The weight of the marker shall not exceed 0.5 Kilograms.Fixing will be by drilling holes on the road for the shanks to go inside, without nails and using epoxy resin based adhesive and complete as directed by the engineer.) |
| 37 | Painting Lines, Dashes, Arrows etc on Roads in Two Coats on New Work (Painting lines, dashes, arrows etc on roads in two coats on new work with ready mixed road marking paint conforming to IS:164 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control ) |
| 38 | Over 10 cm in width |
| 39 | Up to 10 cm in width |
| 40 | Supply, fabrication, and fixing of Mild Steel bollards made from 100 mm diameter, 4 mm thick MS pipe, total height 1000 mm, top end plain, finished with polymer paint in approved color, and provided with two reflective tape bands, 50 mm wide each. Bollards to be fixed by drilling holes in reinforced or plain cement concrete using a power-driven drill machine to a depth of 100 mm, with 10 mm dia × 100 mm steel bolts and washers grouted using approved epoxy resin anchor, ensuring proper alignment. Complete in all respects as per drawing and directions of the Engineer-in-Charge. |
| 41 | Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of class-B Type IV retro reflective sheeting fixed cover 2 mm thick aluminium sheeting vide clause 801.3, 3mm/4mm thick aluminium composite material sheet depending on the size of the sign fixed over back support frame of min 25 x 25 x 3 mm Angle mounted on a mild steel circular pipe 65 NB, 3.2 mm thickness firmly fixed to the ground by means of properly designed foundation with M25 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing. The sign shall be maintained as per section 12 of IRC 67. |
| 42 | 90 cm equilateral triangle (for caution) |
| 43 | 90 cm circular (for speed limit) |
| 44 | 90 cm x 75 cm rectangular (advance direction) |
| 45 | 80 cm x 60 cm rectangular (exit direction) |
| 46 | 60 cm x 60 cm square (Round about Name) |
| 47 | Heavy duty,armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. |
| 48 | 2c x 10 mm2 1.1kV |
| 49 | Earthing with copper earth plate 600mmx600mmx3m thick including accessories ,and providin, masonry enclose with copper plate having locking arrangemen and watering pipe etc. Iwith charcole or coke and salt as required. |
| 50 | P/F 25 x 5mm copper earth strip in ground :- |
| 51 | Providing and fixing 25mmx5mm cpper earth strip in 0.5Mtr below ground as strip earth electrode,including soldering as required. |
| 52 | S/L 8 SWG copper wire in ground (for main panel and AC panel) :- |
| 53 | S/L 8 SWG G.I. wire in ground :- Supplying and laying 8 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required. |
| 54 | Providing , laying and fixing following dia GI pipe (medium Class) in ground complete with G.I.Fittings including trenching (75 cm deep) and refilling etc. as required. |
| 55 | 40 mm dia |
| 56 | 65 mm dia |
| 57 | S.I.T.C of following rating approved make LED Bollard fitting with cylindrical shape and inverted cone shape head of height 600 to 850mm power input-8/9watt with die cast aluminium housing opel with PC diffuser, IP:65/54 protection, conferming to IS:10322 part 5 etc all complete as required. (excluding plinth charge) |
| 58 | S.I.T.C of floowing rating LED Flood lighting luminarie with pressure die cast housing and toughened glass cover (IP 66 protection) in existing pole/pipe for supply voltage 1C[.Z70Y AC,50Hz. Luminarie shall be confirm tolS:,1,0322part-5/section-5 and shall be complete with all neccssary accessories as required50/60 WATT LED Flood Light |
| 59 | Design, fabrication, supply and delivery of 9.0 mtr high decorative Wing Pole made of MS pipe with 3.0 mm wall thickness, comprising 150 mm Ø base pole, 75 mm Ø wing poles on both sides, 50x50 mm MS box section bracket for street lamp mounting, and 600x1200 mm advertisement frame in MS box section, with provision for fixing of luminaire (street light not included in this item), decorative laser cut stainless steel elements as per approved architectural design, complete with base plate, welding, grinding, surface preparation, one coat primer and two coats of epoxy paint of approved shade, including all materials, labour, tools, transport and incidental works as per approved design and drawing. |
| 60 | ).5m Double Arm suitbale for 90mm Top(Basic Rate : Rs. 1380.00 + Overhead & profit @ 14.95% = Rs. 1586.31 ) |
| 61 | Installation, Testing & Commissioning of the 9 Mtr. Octagonal Pole & light fitting with the help of suitable tools and plants, wiring of luminaires with all materials and construction of shallow foundation with M25 grade concrete considering safe soil bearing capacity of 10T/mtrs sq. (Basic Rate : Rs. 8100.00 + Overhead & profit @ 14.95% = Rs. 6207.30 ) |
| 62 | S/F 6 amps to 32 amps rating 240 volts, ‘C’ series miniature circuit breaker suritable for lighting and other loads of following poles in the existing MCB DB complete with connection, testing and commissioning etc. as reqd.6/32 amps,Single pole |
| 63 | SITC of following rating LED street lighting luminari with pressure die cast housing and toughtend glass cover ,IP 66 protection,lumonous EFFICARY>=110 LM/W with lens in existing pole/pipe for supply voltage 100-270 V AC,50 Hz.Luminarie shall be confirm to IS:10322 part 5/section 3 and shall be complete with all necessery accessories as reqquired.120W LED street light |
| 64 | Supplying and drawing following size of FR PVC insulated copper conductor single core cable in existing surface/recessed steel/PVC conduit including dismantling as required 3x1.5 sqmm |
| 65 | Supply of XLPE insulated sheathed (heavy duty) armoured electric cables with Aluminium conductor for working voltage 1100 volts conforming to IS:7098 (part-1)/IS:1554; 4 core x16 sq mm (Basic Rate: Rs. 221.00 + Overhead & Profit @ 14.95% = Rs. 254.03) |
| 66 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required; 4 X 16 sq. mm (28mm) |
| 67 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm direct in ground including excavation, cushioning, protective coveringand and refilling the trench etc. as required |
| 68 | Supplying and laying of 40mm dia medium class GI pipes for road crossing (Basic Rate: Rs. 300.00 + Overhead & Profit @ 14.95% = Rs. 344.85) |
| 69 | Earthing with GI earth pipe 4.5 mtr long,40 mm dia including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal and salt as required. |
| 70 | Supplying and laying 6 SWG GI wire at 0.50 meter below ground level for conductor earth electrode, including soldering etc as reqd. |
| 71 | S.I.T.C of Outdoor stand mounted feeder peelar with 63 amps TP&N,MCB incomer ,65 amps TP contractor automatic switch of luminaries,power tool control incommer outgoing terminal etc as required. (Basic Rate: Rs. 27800.00+ Overhead & Profit @ 14.95% = Rs. 31956.10) |
| 72 | For 16 mtr. High mast: IIC of the high mast and light fixture with the help of suitable tools and plants, wiring of luminaries with all wiring material like PVC insulated PVC sheathed flexible cable of suitable copper conductor lugs, MCB and all labour & construction of shallow foundation with M25 grade concrete for the high mast considering safe soil bearing capacity of 70T / mhs sq. for 16 M High mast. (existing high mast light for members) |
| 73 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concree, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with allk lifts and lead of 1000 metres (For dismembering existing high mast) |
| 74 | Steel work in all types of sections upto a height of 5m above plinth level excluding cutting of rivet. |
| 75 | Including dismembring |
| 76 | Supply and installation of green wall system including fabrication and fixing of MS frame made of rectangular MS pipe (2”x1” and 2”x2”) with proper supports, welded or grouted as required, painted with primer and two coats of paint to prevent corrosion; complete drip irrigation system of approved make (Jain Irrigation) with accessories such as end cap, bend, tee, socket, 12 mm and 16 mm lateral pipes, 4 & 8 LPH drippers, and water filter; supply and installation of vertical garden units comprising PVC frames and pots (frame size 7”x21” for 3 pots) with drip irrigation arrangement, including transportation and shifting of materials to site, fixing of frames and pots, supply of engineered pot mixture (cocopeat, sand, soil, immunity boosters, manure, charcoal powder, micro-nutrients, etc.) and filling of pots, plantation of natural indoor plants (Money Plant, Oxicardium, Philodendron, Peperomia, Red Congo, Syngonium, Berkin, Xanadu, Ferns, etc.) and outdoor plants (Syngonium, Pandanus, Sprengeri, Ficus, Rhoeo, Setcretia, Ophiopogon, Alternanthera, Dracaena, Zade, Chlorophytum, etc.), all complete for a fully functional and sustainable green wall system as per specification and direction of Engineer-in-Charge. |
| 77 | DMC logo and letter Please Enable Macros to View BoQ information |
| 78 | DMC logo and letter Please Enable Macros to View BoQ information |