| 1 | Demolition of Brickwork built in Cement Mortar including all quoins, arches, pillars, etc. of any descriptions, ccomplete all as specified and as directed. |
| 2 | M&L for Brick work with sub class 'B' brick straight of curved on plan exc 6m mean radius built in CM (1:6) complete all as specified and as directed. |
| 3 | M&L for Brick work with sub class B bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar (1:4) complete all as specified and directed. |
| 4 | Excavation in trenches n. exc 1.5 mtr wide and n. exc 1.5 mtr deep for foundation etc. n. exc 10 Sqm on plan and n. exc 1.5 mtr deep and getting out in any type of soil complete all as specified and as directed. |
| 5 | Returning filling including spreading, leveling, watering in layers n. exc. 25cm in any type of soil complete all as specified and directed. |
| 6 | Removing excavated soil to a distance exc. 50 mtr and n. exc 250 mtr from starting point complete all as specified and directed. |
| 7 | M&L for providing cement concrete with type B1 (1:2:4) using (20mm graded stone aggregates) as in coping and the like including weathering slightly rounded or chamferred angles and throating complete all as specified and as directed. |
| 8 | Dismantling posts or struts (wood, steel or R.C.C.) any section embeded in concrete, brick work, masonary etc including taking out embedded portion and making good disturbed ground complete all as specfied and as directed. |
| 9 | Dismantling fencing wire mesh, any type complete all as specfied and as directed. |
| 10 | Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out, returning,filling in & ramming earth or broken rubble mixed with earth around, in layers not exceeding, 25 cm watering & removing surplus soil to a distance n exc 50m and making good surface in any type of soil complete all as specified and as directed. |
| 11 | M&L for providing cement concrete type C-2 (1:3:6) using (40 mm graded stone aggregates) as in foundations, filling and mass concrete complete all as specified and as directed. |
| 12 | S&F mild steel joist, channel, angle, or tee section, fixed independantly, without connecting plates, etc. as in fencing post including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe 410 W (gde E-250 quality B) complete all as specified and as directed. |
| 13 | S&F Steel work in tubular trusses, posts,rafters, purlin,struss etc including special shaped washers etc using ERW or induction butt welded tubes incl preparation surfaces etc complete all as specified and directed. |
| 14 | S&F chain link MS galvanised fencing of approved size or type weight as directed per square metre as approved complete all as specified and as directed. |
| 15 | S&F chain link fencing of P.V.C coated MS wire mesh roll of 10 gauge of 50 mm x 50 mm size mesh fixing firmly to the existing M.S angle vertical pole of fencing with 8mm dia 50 mm G.I Bolt and GI flat 35 mm x 4 mm/100mm long G.I wire cost including all required materials, fixtures, labour and machinery etc. complete all as specified and directed. |
| 16 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 17 | S&F Galvanised 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. (each line wire to be measured) complete all as specified and as directed. |
| 18 | S&F in repairs stainless steel concerntina coil fencing with punched tape concerntina coil 600mm dia 10 mtr openable length (total length 90mtr), having 50 nos round per 6 mtr length upto 3 mtr heigth of wall with 9 horrizontal RBT reinforced barbed wire, stud tied with GI satples and GI clips to retain horrizontal, including nessesary bolts or GI barbed wire tied with angle iron complete all as specified and as directed |
| 19 | S&F TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (Annealed) not less than 0.90 mm dia or securing with clips quality conforming to round bars complete all as specified and directed. |
| 20 | S&F MS flat iron as for securing wire mesh etc. posts and struts in fencing including cutting tops to shapeas directed, drilling holes,notching for wire, etc. flat ironfillets) including all necessary drilling, bolting or riveting, etc.,and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 21 | S&F Mild steel screw bolt (machine made with hexagonal or square head at one end and screwed the other or screwed both ends each screwed end to be fitted with washers and one hexagonal or square n exc 5 cm long dia of neck 5 to 10 mm complete all as specified and directed. |
| 22 | Dismantling asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specfied and directed. |
| 23 | S&F prepainted galvalume aluminum zinc coating GI based semi corrugated / Mangalore steel sheet 0.50mm thick of colour as approved having tensile strength of 550 MPa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 24 | S&F prepainted galvalume aluminium zinc coating plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 MPa as in roof ridges /cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 25 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 26 | S&F Mild steel framed work such as grills, gratings etc. with ends of bars shouldered and/or riveted or forged into spikes; framed guard bars, barred iron doors, iron gate, ladders; framed balusters, ways : railing : frame work of watertanks and similar work conforming Fe-290, Gde E-165 complete all as specified and directed. |
| 27 | M&L for PCC type B-2 (1:2:4) using (40 mm graded stone aggregates) as in surface channels and drains complete all as specified and directed. |
| 28 | M&L for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/ stopped ends etc. complete all as specified and as directed. |
| 29 | Demolition of cement concrete (unreinforced) of any descriptions, in ground floors (floor topping, sub base etc) not exc 15cm thick, above or below ground level complete all as specified and directed. |
| 30 | M&L for 75mm thick PCC (1:3:6), type C2, using 40mm graded stone aggregates as in plinth protection / paving, surfae finished even & smooth with using extra cement as complete all as specified and as directed. |
| 31 | M&L for hard core of gauge in exc. 63mm broken stone boulders deposited and spred and leveled in layers in.exc. 15mm thick complete all as specified and directed. |
| 32 | M&L for 100 mm thick PCC type B1 (1:2:4) (20 mm graded stone aggregates) as in flooring, hard standing or at any place finished even and smooth with using extra cement complete all as specified and directed. |
| 33 | M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregates) as in sub base complete all as specified and as directed. |
| 34 | Dismantling of interlocking tile 60-80mm thick complete all as specified and directed. |
| 35 | M&L for 25 mm thick sand cushion under paver block or interlocking tiles floor including watering and consolidation complete all as specified and as directed. |
| 36 | M&L for 80 mm thick coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-40 Grade with grey cement and no pigment complete all as specified and as directed. |
| 37 | M&L for 60 mm thick coloured machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658- 2006 M-35 Grade with grey cement and no pigment complete all as specified and as directed. |
| 38 | Refixing only of interlocking tiles obtain from BOQ Serial item No.36 above complete all as specified and as directed. |
| 39 | Refixing only of interlocking tiles obtain from BOQ Serial item No.37 above complete all as specified and as directed. |
| 40 | Demolition of reinforced cement concrete (re-inforcement cut as required to facilitate demolition) of any descriptions, in ground floors not exc 150mm thick, above or below ground level complete all as specified and directed. |
| 41 | M&L for reinforced cement concrete (nominal mix) type B1 (1:2:4) (using 20 mm graded stone aggregates) as in walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses any thickness complete all as specified and directed. |
| 42 | M&L for providing RCPC, factory made, 75mm precast RCC cover slab of 3MT load bearing capacity conforming to IS : 12592 (Grade M-30) for drain cover and manhole cover complete all as specified and as directed. |
| 43 | M&L for providing RCPC, factory made, 75mm precast RCC cover slab of 5MT load bearing capacity conforming to IS : 12592 (Grade M-30) for drain cover and manhole cover, complete all as specified and as directed. |
| 44 | M&L for precast cement concrete (1:2:4) type B-1, (using 20mm graded stone aggregates) as landings, cover slabs (for manholes etc), chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar (1:4) complete all as specified and as directed. |
| 45 | M&L for PCC (1:2:4) type B-0, (using 12.5mm graded stone aggregates) as in kerb/ benching/ coping, bed plates, for fixing of hold fast,chajjas, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed. |
| 46 | M&L for 50 mm thick cement concrete type C-2, 1:3:6 (using 40mm graded stone aggregates) as in sub base floor, hard standing and like complete all as speficied and as directed. |
| 47 | Taking down eaves gutters and rain water pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, reinforced concrete drain pipes etc., including cleaning or refixing or removal to store (measured overall length as fixed along the centre line over fittings and accessories) complete all as specified and as directed. |
| 48 | S&F PVC (SWR)110 mm bore pipes, single socketed in any length with rubber ring joints and fixed to wall complete all as specified and as directed. |
| 49 | S&F 110 mm bore PVC (SWR) bends, any radius including necessary cutting in brick wall and making good to match with existing surface complete all as specified and as directed. |
| 50 | S&F 110 mm bore PVC (SWR) junction single, (single T) equal or unequal provided with access door complete all as specified and as directed. |
| 51 | S&F 110mm dia PVC (SWR) vent cowl any radius complete all as specified and directed. |
| 52 | Dismantling of stone slabs and tiles of any description or thickness in floors, aprons, etc laid, bedded & pointed in any mortar complete all as specified and as directed. |
| 53 | M&L for 20 mm thick granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like over and including 15mm thick cement mortar bedding (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. Note:- (i) Screed bed shall be measured and paid seperately. (ii) Size of Granite shall be as per sample and as decided by GE |
| 54 | M&L for granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and as directed. |
| 55 | M&L for screed bed or bedding layer 20 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and directed. |
| 56 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and as directed. |
| 57 | M&L for glazed earthenware tiles 149mm x 149mm (or 152.4mm x 152.4 mm) x 6mm thick, in vertical surfaces such as skirtings, dados and risers to steps etc, etc,set and jointed in neatcement slurry andpointed in white orcoloured cement to match complete all as specified and as directed. |
| 58 | M&L for pre-polished cement concrete, designer, coloured chequered tiles, glossy finish of area n exc 0.16 sqm as in floor set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade of the tiles and laid over and including 15 mm thick screed bed in cement mortar (1:6) over and including 40mm PCC (1:2:4) type B-0, (using 12.5mm graded stone aggregates) complete all as specified and as directed. |
| 59 | M&L for glazed ceramic (coloured) tiles of size 600 x 300 x 6-7mm thick as in vertical surface/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 60 | M&L for glazed ceramic (coloured) tiles of size 450 x 300 x 6-7mm thick as in vertical surface/dado set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 61 | M&L for non-skid, joint free, ceramic coloured tiles, area of each tiles (square/rectangular) exc 0.11 sqm but n. exc 0.18 sqm 7 to 8 mm thick in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. Note: Screed bed shall be measured and paid separately. |
| 62 | M&L for double charged vitrified ceramic tiles 9-10 mm thick (Square/ rectangular) polished, minimum area of each tiles not exc. 0.36 sqm, in floors etc. set and jointed with adesive and pointed in epoxy grout with spacers over and including a bedding layer of scread bed 15 mm thick in CM 1:6 complete all as specified and directed. |
| 63 | M&L for double charged vitrified ceramic tiles 9-10 mm thick (Square/ rectangular) polished, area of each tiles exc. 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed with adesive and pointed in epoxy grout with spacers over and including a bedding layer of scread bed 15 mm thick in CM (1:6) complete all as specified and directed. |
| 64 | M&L for screed bed or bedding layer of mortar 15 mm thick in CM (1:6) for laying floor finishes complete all as specified and directed. |
| 65 | M&L for bedding layer of mortar 10 mm thick in CM (1:3) for laying wall/dado finishes complete all as specified and directed. |
| 66 | M&L for cleaning of deposited earth, silt, debris, sludge, water from drain and removal of debris to outside or inside the premises of MoD land exc.1.50 km but n exc. 5 km and depositing where directed complete all as specified and as directed. |
| 67 | M&L for rotational moulded polythylene water storage tanks 300 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position with & including 20 mm brass valve high pressure with polythene float and fly nut and GI tank nipple, screwd for iron pipe complete all as specified and directed. |
| 68 | M&L for rotational moulded polythylene water storage tanks 500 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position with & including 20 mm brass valve high pressure with polythene float and fly nut complete and GI tank nipple, screwd for iron pipe complete all as specified and directed. |
| 69 | M&L for rotational moulded polythylene water storage tanks 1000 litres capacity (cylindrical vertical with closed top) hoisted and fixed in position with & including 20 mm brass valve high pressure with polythene float and fly nut complete and GI tank nipple, screwd for iron pipe complete all as specified and directed. |
| 70 | Taking down cement plaster or lime plaster of any description from stone or brick wall/ ceiling etc including raking out joints, hacking for key scrubbing down with water and including necessary scaffoldings complete all as specified and directed |
| 71 | M&L for rendering 20 mm thick cement plaster in CM (1:4) on external surfaces of brick walls finishing even and smooth with out using extra cement including necessary scaffoldings complete all as specified and as directed. |
| 72 | M&L for rendering 15 mm thick cement plaster in CM (1:6) on internal surfaces of brick wall or concrete surfaces finished even and smooth without using extra cement including necessary scaffoldings complete all as specified and as directed. |
| 73 | M&L for rendering 5 mm thick cement plaster in CM (1:3) on fair faces of ceiling and finish smooth without using extra cement including necessary scaffoldings complete all as specfied and directed. |
| 74 | M&L for applying one coat of 100% premium acrylic exterior emulsion paint on old decorated surfaces having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including a coat of primer complete all as specified and directed. |
| 75 | Complete removal of old decorated surfaces and M&L for finishing walls by applying two coats of premium acrylic smooth exterior paint with silicone additives of required shade andapplied @ 1.43 ltr/10 sqm over and including a priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified & directed. |
| 76 | M&L for applying two coats of 100% premium acrylic exteror emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (company depot tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including a priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified & as directed |
| 77 | Preparation of old painted surfaces of steel & iron surface of any description over 10 Cm width or girth and M&L for applying one coat of synthetic enamel paint complete all as specified and directed. |
| 78 | Preparing of new steel surfaces & M&L for applying two coats of synthetic enamelled paint over a coat of red oxide primer complete all as specified and as directed. |
| 79 | Preparation of plastered and unplastered surfaces of old decorated walls and M&L for applying one coat of acrylic oil emulsion distemper complete all as specified and directed. |
| 80 | M&L for 2mm thick wall care putty on wall in two layers including rubbing with sand paper to achieve a smooth surface & sharp straight edges etc. complete all as specified & as directed. |
| 81 | Preparation of newly plastered wall surface and M&L for applying two coats of oil bound distemper over and including a coat of primer on complete all as specified and directed. |
| 82 | Preparation of newly plastered ceiling surfaces and M&L for applying two coats of oil bound distemper complete all as specified and directed. |
| 83 | M&L for two coats of water based floor paint on cement concrete & tile floor surfaces. The surface must be completely cleand, dried and free of oil, grease, plish and wax or other surfaces contaminants prior to application of paints. Apply two coats with uniform brush strokes. Second coat must be applied after 24 hrs of first coat application, complete all as specified and directed. |
| 84 | M&L for solid PVC Wall lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing with 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame complete all as specified and directed. |
| 85 | M&L for 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame complete all as specified and directed. |
| 86 | S&F in repairs suspended false ceilling system using metalic (E grid) exposed suspended system, grid section size 600mm x 600mm comprising of GI powder coated main runner of dimension 39 mm x 24mm x 0.80mm thick (thickness comprising of GI/0.4+ PPPCGS/ 0.3mm & weight of Runner 1.35 kg for 3600mm length), cross tee of dimension 29mm X 24 mm x 0.8 mm thick wall angle 22.2mm x22.2mm x 0.65 mm thick (thickness comprising of GI/0.35 + PPPCGS/0.3 mm & weight of angle 0.70 kg for 3050 mm length) with and including 6 mm thick HPSC (high pressure steam cured) preprimed, self embossed textured designer board, water resistant termite resistant, fire resistant for insulation and accustic purpose to be placed in the grid system duly suspended with 6 mm dia G I bars hangers fixed with steel dash through fasteners from purlins of the roof with butterfly clips (Wt- 0.007 Kg/clip) hold down clips (Wt - 0.0035 Kg/clip) with provns of light fixture complete all as specified and as directed. |
| 87 | M&L for PCC type B-0 (1:2:4) using (12.5 mm graded stone aggregates) in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed. |
| 88 | M&L for 2mm fibre glass reinforced translucent plain sheeting with two plain side lap fixed with coach screw and washer in roof, wall etc complete all as specified and directed. |
| 89 | M&L for applying one coat of synthetic enamel paint, area exc.10cm width or girth over kerb stone or any other surfaces including preparation of surface complete all as specified and as directed. Please Enable Macros to View BoQ information |