| 1 | Dismantling Asbestos cement (corrugated, semicorrugated, etc.) /GI sheets in roof coverings etc complete all as specified |
| 2 | Dismantling timber scantling 40 Sqcm and over in section in any position (framed works). |
| 3 | Dismantling of fillet rails, post, rafter, purlin etc under 40 Sqm in section in framed work. |
| 4 | Dismantling boarding any discription fixed in any position with nail including cover fillets. |
| 5 | S&F, Pre-painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall ,fixed with self tapping screws complete all as specified and as directed. |
| 6 | Refixing pre-painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall ,fixed with self tapping screws complete all as specified and as directed. |
| 7 | S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 8 | S&F Plain, galvanised, mild steel sheeting, in 1.0 mm thick ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 |
| 9 | M&L Rolled section as in rafter purline strut etc using MS angle FI or hollow square section etc including cutting welding nut bolt etc complete |
| 10 | S&F Roof trusses (framed) trussed, purline crane gantries ,rails and fastenings and heavy brackeet framing (Beam,tee,angle, channel or flat sections) including distance pieces ,cleats etc Fe-410-W (Gde-E-250)quality-A |
| 11 | M&L MS Nut Bolt washer with Hexagonal head of dia more than 10mm and length as directed complere. |
| 12 | S&F MS flat iron as in Wind tie etc including cutting drilling hole etc complete |
| 13 | S&F Mild steel works as in hold fasts, clamps, plain angle cleats for securing purlins to wood trusses or rafters, cooler stands and similar small articles conforming to Fe 290-0 or Gde-E-165 |
| 14 | M&L PCC 1:2:4 type B1 using 20 mm graded stone aggregate for insertion of hold fast incl necessary form work etc all complete. |
| 15 | S&F suspended false ceiling using Chicago metallic E-Grid exposed suspended sys , grid sec size 600 x 600mm comprising of GI powder coated main runners of dim 39 x 24 x 360 x 0.88 mm thick (thickness comprising 0.40 mm + PPP GSO 30 MM and weight of runners 1.35 kg for 3600 mm length. Gross T of dimension of 29 x 24 x 600 x 0.80 mm thick. The thickness of comprising GI 0.040 mm + PPPC GS (0.30 mm and weight of T 0.195 kg for 6000 mm length) and wall angle of dimension 22.2 x 22.20 x 3050 x 0.65 thick (the thickness comprising of GI 0.35mm + PPGC GS 0.30 and eight of angle 0.70 kg for 3050 mm length) with the grid system duly suspended with 4mm dia GI war hangers fixed with steel dash trough fasteners from purline of the roof with butterflyclips (wt 0.007 kg per clip) hold down clip wt 0.0035 kg per clip) with provision of complete all as specified and as directed. Note:-PPPCGS Densts Prep anted Polysters Coated Galvanised steel. |
| 16 | S&F 6mm Non asbestos fibre cement building boards fixed or laid /inserted to timber /GI/Aluminium framework with screws fixed in ceiling flat or sloping |
| 17 | Refixing only Non asbestos fibre cement building boards fixed or laid/ inserted to timber/GI/Aluminium framework with screws ceiling flat or sloping |
| 18 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and disposing the rubbish to the out side of MD land. |
| 19 | M&L Non skid joint free tiles coloured ceramic tiles 7 to 8 mm thick (square/Rectanglar) area of each tiles exc 0.18 Sqm but not exc 0.38 Sqm in floor area over and including 15mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 20 | M&L for coloured glazed ceramic tiles 450x300x7 mm thick but as on vertical surfaces such as skirting/dado including 10 mm thick rendering in CM 1:3, complete all as specified and as directed. |
| 21 | M&L machine cut kota stone slab as in flooring 20 to 25 mm thick in floor over and including screed bed 15mm thick or bedding layer for laying floor finishes CM 1:4 etc set and jointed in neat cement slurry and jointed with greay cement slurry mixed pigment to match shade of slab incl rubbing and polishing complete all as specified and as directed and as directed. |
| 22 | M&L machine cut kota stone slab as in flooring 20 to25 mm thick riser of steps, skirting, dado and pillar laid over and including 10mm thick rendering in CM 1:3 complete all as specified and as directed. |
| 23 | M&L 75 mm thick PCC 1:3:6 type C-2 using 20mm graded aggregate as in plinth protection finishing even & fair without using extra cement laid in bays with construction, 6mm thick joints should be filled with bitumen mastic filling comprising of one part of heated bitumen 80/100 gde and three part of sand ( all by weight) complete. |
| 24 | M&L in rapair mirror polishing on marble / granite / kota stone /stone work where ever required to give high gloss finish complete as per specified and as directed |
| 25 | Demolition of cement concrete (unreinforced) of any description in any position complete all as specified and directed |
| 26 | M & L PCC 1:2:4 type B1 using 20mm graded aggregate as in hold fasts, benching, coping, repair to chajjas, facia etc in window cills projecting type and similar work all as specified and as directed. Note : Necessary form work be included in the unit rate of this item. |
| 27 | M&L cutting out cracks to V section in existing roof or terracing cleaning out and filling solidly with a hot mixture of bitumen and clean dry sand @ 1:1 (by weight). |
| 28 | M & L PCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in padding concrete to maintain slope complete all as specified. |
| 29 | M&L 10 mm thick cement plaster in CM (1:4) mixed with water proofing compound as per manufacturer instructions over while the padding concrete is still green complete all as specified and as directed. Note : WPC shall be measured & paid separately under relevent items. |
| 30 | M&L Water proofing treatment on \\"non accessible\\" surface (Horizontal & Vertical surfaces) in following sequence through manufacturer / authorized applicator of the manufacturer including taking down of existing roof treatment with old pcc padding and plastering, properly cleaning & drying the concrete surfaces including removing debbries out of MOD land complete |
| 31 | Priming surfaces and applying one coat of cold bituminous primer @ 0.25 Ltr/Sqm conforming to IS : 3384-1986 |
| 32 | Applying APP based polymeric membrane minimum weighing 3 kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) laid on primed surface by torch application including two coat of aluminium paint on top complete all as specified. |
| 33 | Supply only integral water proofing liquid compound. |
| 34 | Dismantling water tank 1000 ltr and removing from site complete all as specified and as directed. |
| 35 | S&F 1000ltr Rotaional moulded polyethylene water storage tanks cylindrical vertical with closed top hoisted and fixed in position all as specified |
| 36 | Taking up or down 15mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 37 | Taking up or down 20mm dia GI steel tubing and connections, including cleaning for refixing or removal to store complete all as specified and as directed. |
| 38 | S&F GI tube 15 mm dia medium grade galvanised with all fittings laid in floors /wall etc. complete all as specified and as directed. |
| 39 | S&F GI tube 20 mm dia medium grade galvanised with all fittings laid in floors /wall etc. complete all as specified and as directed. |
| 40 | Taking down Chowkhats or frames with shutters (wihout taking off shutters) from the frame exc 1.5 sq. m but n exc 4 sq. m complete all as specified and as directed |
| 41 | S&F pressed steel frames (size 125x60mm) for doors with one or more rebates incl necessary fixings lugs, hinges, lock strike plate etc complete all as specified and as directed. |
| 42 | M&L providing plain cement concrete 1:3:6 Type C-0 (using 12.5mm graded stone aggregate) as in filling hollow of pressed steel frame. |
| 43 | S & F 35mm thick “FACTORY MADE MOULDED DOOR SHUTTER\\" consisting of solid core single leaf Flush Door of 30mm thickness, lipped with 15mm (5mm x 3) thick x 30mm width on one stiles and top rails & 10mm (5mm x 2) thick x 30mm width on the other stiles & bottom rails. The inner panel laminated with 2mm thick Sheet of Density 700 Kg /Cbm Manufactured by an ISO-9000 certified Company, termite proof, water proof and fire resistant moulded PVC Sheet with 2, 4, 6 raised panel design in different plain and / or prelam colours on one side after routing the Moulded design on flush door & 2mm plain and /or prelam PVC sheet on other side using rubber based adhesive on flush door & solvent cement adhesive on the PVC lipping etc. complete as per direction of Engineer-in-charge, manufacturer’s specification and drawing complete all as specified and directed. |
| 44 | S&F 35mm thick 2nd class hardwood glazed and skeleton shutters open rebated and prepared to receive glass, gauze, etc. divided in to squares,with plain, chamfered or rounded , mitred and rebated sash bars,any numbers ; edges of framing plain, chamfered or rounded , fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause 8.24 (b) of factory made complete all as specified and as directed. |
| 45 | S&F stainless steelwire cloth.0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples. |
| 46 | S&F 300 mm long aluminium alloy, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts complete all as specified and as directed. |
| 47 | S&F aluminium anodized barrel tower bolts 200 mm of extruded section and fixed. |
| 48 | S&F 150 mm size aluminium alloy handles, febricated type extruded section, ISI marked all as specified. |
| 49 | S&F 300 mm long mild steel ordinary rat tail rod pattern springs including roller & roller plate and necessary welding for fixing complete all as specified. |
| 50 | S&F 150 mm long floordoor stopper of aluminium door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring complete all as specified and as directed. |
| 51 | M&L preparation of new wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of primer complete. |
| 52 | S&F framed work such as grills,gates, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 53 | S&F in repair door closer aluminium extruded section hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed Please Enable Macros to View BoQ information |
| 54 | S&F in repair door closer aluminium extruded section hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed Please Enable Macros to View BoQ information |