| 1 | Taking down carefully old unserviceable point wiring complete incl fittings such as switches, conduit,wires,celling roses, light fittings etc and making good the disturbed surface complete all as specified and as directed. |
| 2 | M&L for point wiring complete with 2 runs of 1.5 sqmm single core PVC insulated unsheathed FRLSH cable 1100 volts grade ISI marked with multi stranded copper conductor drawn through and including steel conduit and steel conduit accessories such as threaded type steel junction boxes ,threaded sockets,bends etc ISI marked medium grade concealed in wall/fixed to roof/ceiling etc and including provision of 1.5 sqmm PVC insulated multistranded unsheated copper conductor cable FRLSH ISI marked as earth continuity conductor for one light point or one fan point controlled by one switches complete all as specified and as directed. .- Note :- (i) One run of steel conduit pipe,two runs of PVC wire and one run of earth wire will be measured as one length. (ii) The chases in the wall shall be cut with elect cutter (iii) The disturbed surfaces of wall shall be made good with cement plaster 1: 4 including matching the surfaces with two coats of white wash / colour wash all as per existing finishes and to the entire satisfaction. |
| 3 | M&L for point wiring complete with 2 runs of 2.5 sqmm single core PVC insulated unsheathed FRLSH cable 1100 volts grade ISI marked with multi stranded copper conductor drawn through and including steel conduit and steel conduit accessories such as threaded type steel junction boxes ,threaded sockets,bends etc ISI marked medium grade concealed in wall/fixed to roof/ceiling etc and including provision of 2.5 sqmm PVC insulated multistranded unsheated copper conductor cable FRLSH ISI marked as earth continuity conductor for one light point or one fan point controlled by one switches as specified and as directed.- [Note :-(i) One run of steel conduit pipe,two runs of PVC wire and one run of earth wire will be measured as one length. (ii) The chases in the wall shall be cut with elect cutter (iii) The disturbed surfaces of wall shall be made good with cement plaster 1: 4 including matching the surfaces with two coats of white wash / colour wash all as per existing finishes and to the entire satisfaction] |
| 4 | M&L in repairs for two single core (submain) PVC insulated cable with 2.5 sqmm nominal cross sectional area FRLSH multistranded copper conductor,1100 volt grade and one single core green PVC insulated 2.5 sqmm stranded copper conductor earth continuity cable drawn through non metallic, medium duty, rigid MS conduit not less than 25 mm dia concealed in wall including all conduit and fixing accessories including taking down existing sub main wiring, cutting chases as required & making good disturbed surfaces as per existing complete all as directed. [Note:- (I) The cost for taking down,cutting, chases & making good as required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of MS conduit shall be measured as one RM] |
| 5 | M&L for concealed sub main wiring with 3 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core cable of working voltage 1100 volts grade with stranded copper conductor drawn in PVC rigid non- metallic conduit complete all as specified and as directed. NOTE : (i) Three run of submain wiring cable alongwith 20mm PVC conduit pipe shall be measured as one unit length. |
| 6 | S & F in replacement LED 1 x 16 Watt industrial Flame proof tube light fittings,CMRI certified complete all as specified and as directed. |
| 7 | S & F in replacement LED/HPMV/HPSV 1x8 Watt industrial Flame proof tube light fittings pendent type fitted on the roof ceiling hook, CMRI certified, complete all as specified and as directed. |
| 8 | Supply and fixing in repair Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and as directed. |
| 9 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators complete all as specified and as directed. |
| 10 | S&F MCB, Single pole & neutral,6 to 40 amps, 240 volts, ‘C’ curve, 10KA all complete as specified and as directed. |
| 11 | S&F MCB, Single pole, 6 to 32 amps, 240 volts, ‘C’ curve, 10 KA all complete as specified and as directed. |
| 12 | S&F in ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed. |
| 13 | S&F switch piano flush type 5/6 amps single pole one way complete all as specified and as directed. |
| 14 | S&F switch piano flush type 5/6 amps single pole two way complete all as specified and as directed. |
| 15 | S&F switch piano flush type 15/16 amps single pole one way complete all as specified and as directed. |
| 16 | S&F Switch socket combination 2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with and including taking down existing unserviceable, complete all as specified and as directed. |
| 17 | S&F Switch socket combination 2 in 1, 6 pin 5/6 amps and 15/16 amps multipurpose, white/ivory finish flush non shutter non inter locking type with and including taking down existing unserviceable, complete all as specified and as directed. |
| 18 | S & F in repair ultra bright integrated aluminium heat sink LED tube rod 18 watt (single side connection) with high efficiency suited for installation in existing t-8 fitting with g-13 lamp holders complete all as specified and as directed. |
| 19 | S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 120 mm including taking down existing unserviceable complete all as specified and as directed. |
| 20 | S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 170 mm including taking down existing unserviceable complete all as specified and as directed. |
| 21 | S&F in repair hylam sheet 3 mm thick white in colour of size 200 mm x 100 mm including taking down existing unserviceable complete all as specified and as directed. |
| 22 | S&F in repair hylam sheet 3 mm thick white in colour round type of size 80 mm dia including taking down existing unserviceable complete all as specified and as directed. |
| 23 | S & F wall mounted 4 feet LED tube light(Warm) fittings 1 x 18/20 watts 230 Volt white powder coated slim box type (decorative) batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 Single side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to cealing rose ccomplete all as specified and as directed. |
| 24 | S&F IP 20, class I, LED light 1X20 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed. |
| 25 | S&F LED Mirror light fitting 1 x 10 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser, integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified and as directed. |
| 26 | S&F of Bulk head luminaire suitable for 10 Watt LED (or nearest next higher wattage) light IP66 grade, luminaire efficiency not less than 120 lumens/watts with and including 10 watt LED (or nearest next higher wattage) lamp and connecting up with and including PVC insulated 3 core of size 0.75 Sqmm copper conductor from ceiling rose to terminal block of light fitting including necessary taking down the old unserviceable fitting complete all as specified and as directed. |
| 27 | S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 35 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete incl removal of old unsv fitting complete all as specified and as directed. |
| 28 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators complete with and including taking down old unserviceable one complete all as specified and as directed. |
| 29 | S & F MCB TPN 415 volts suitable for fixing in MCB DB of capacity 16 to 32 amps complete all as specified and as directed. |
| 30 | S&F MCB, Triple pole & neutral 63 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and as directed. |
| 31 | M&L for earthing complete with Galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25M deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI strip 25x4mm thick as earthing leads by means of bolt, nut, check nuts and washers galvanised iron or steel all as shown in elctrical plate No 5 of SSR Part I connected to earthing test point or as specified or indicated and testing on completion including excavation and earth work, PCC pit with RCC cover having suitable handle, 32mm bore GI Medium grade watering pipe with funel and wire mesh, 15 mm dia GI Light grade Protection pipe complete all as specified and as directed. |
| 32 | Fixing in repair the existing dislocated/fallen air termination rods 300mm long,12 mm dia fixed on PCC blocks/on GI pipe/ directly on roof including GI pipe etc, complete all as specified and as directed. |
| 33 | Fixing in repair the inspection boxes/ test points terminal block made of gun metal or phosphrous bronze size 75 X 75X 75 mm drilled and screwed including 3 nos 8mm dia 25mm long hexa head screw.type complete all as specified and as directed. |
| 34 | Fixing only in repair Aluminium Strip 25 x 3 mm with saddles & fixing screws etc,for earth continuity conductor main earthing lead , roof conductor & down conductors above ground suitably fixed to wall or concealed in wall , or passing through pipes incl. all necessary fixing arrangement for lightning protection complete all as specified and as directed. |
| 35 | Fixing only in repair iron strip of size 32 x 6 mm buried in ground or fixed on wall mounted on suitable sized porcelain insulators ( on floor and wall only) including cutting cavities for fixing of porcelain insulators and finishing with cement plaster on wall /floors and connected to test point including bending, jointing at test points with GI nuts, bolts, with lead washers, jointing strips at all joints incl. making good the disturbed surfaces complete all as specified and as directed. |
| 36 | S&F Aluminium Strip 25 x 3 mm with saddles & fixing screws etc,for earth continuity conductor main earthing lead , roof conductor & down conductors above ground suitably fixed to wall or concealed in wall , or passing through pipes including all necessary fixing arrangement for lightning protection complete all as specified and as directed. |
| 37 | S&F galvanised iron strip of size 32 x 6 mm buried in ground or fixed on wall mounted on suitable sized porcelain insulators ( on floor and wall only) including cutting cavities for fixing of porcelain insulators and finishing with cement plaster on wall /floors and connected to test point including bending, jointing at test points with GI nuts, bolts, with lead washers, jointing strips at all joints incl. making good the disturbed surfaces complete all as specified and as directed. |
| 38 | S&F air termination single pointed aluminum rod of 12mm dia, 300mm long fixed with 02 nos sutable sized nuts,bolts & washers incl. making good the disturbed surfaces complete all as specified and as directed. |
| 39 | S&F in repair of test point terminal block made of gun metal or phosphorous Bronze 75x75x 25 mm dilled and screwed incl 3 Nos 8mm dia 50 mm long hex head screws rectangular opening at top and bottom for entry of down earth strip, fixing screws and bolts for mounting on wall complete all as specified and as directed. |
| 40 | Fabrication and installation of cubical shape enclosure made of MS/CRCA sheet 2.00 mm thick with front detachable cover,anodixed fiexing screw cap, washer 4 Nos to be mounted on wall with wooden plugs &screws 4 Nos duly painted inside and outside by two coats of aluminium paints over a coat of redoxide primer overall dimension of enclosure 150mm x150mm x100mm (depth) for fixing inside test point terminal bolck complete all as specified and as directed. |
| 41 | S&F suitable sized heavy duty bridge/post porcelain/mini busbar insulator on wall / roof with suitable size of PVC plugs / gutties,screws for fixing aluminium / GI strip incl. making good the disturbed surfaces complete all as specified and as directed.. |
| 42 | M&L for PCC in foundation, for filling of road,in plinth protection,as in bed plates for fixing of aluminum strip etc in PCC (1:3:6) type C -1 with 20 mm graded stone aggregate complete all as specified and as directed. |
| 43 | M&L for GI Pipe medium grade 40 mm dia for fixing of air termination single pointed aluminum rod of 12mm dia, 300mm long on the roof of builings for effective lightning protection system including PCC for fixing complete to the satisfaction complete all as specified and as directed. Please Enable Macros to View BoQ information |