| 1 | Dismantling post (Wood/Steel or RCC) any section including taking out embedded portion in concrete, brick work, masonry etc, and making good disturbed portion complete all as specified and directed. |
| 2 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 3 | Demolition for brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, facings, dressed stonework and precast concrete articles and removal or rubbish off the site complete all as specified and directed. |
| 4 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 5 | M&L for cement concrete in PCC 1:3:6, type C1(using 20 mm graded stone aggregate) as in foundation filling and mass concrete for post holes complete all as specified and directed. |
| 6 | M&L brick work with fly ash old size bricks straight or curved on plan exc 6 m mean radius build in CM 1:6 all as specified as directed. |
| 7 | All as per BOQ item No 6.00 here-in-before but except bricks complete all as specified and directed. |
| 8 | M&L for PCC 1:3:6 type C1 using 20mm stone aggregate as in coping finished even an fair complete all as spd and directed |
| 9 | M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) and finish fair & even complete all as spd and as directed |
| 10 | Excavating in post holes ( or similar holes) each n.exc 0.5 cum getting out and removing surplus soil to a distance n.exc 50m and making good surface, in soft/loose soil. |
| 11 | S&F for Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars,for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire,etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 |
| 12 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and directed. |
| 13 | Supply only PVC coated Galvanised iron wire using Hot Dip technology chain electrogalvanised coating chain link fencing wire mesh of size 50mmx50mm minimum dia meter of wire 3 mm confirming to IS -2712-2003 havinga tensile strength 400 to 500 Mpa and and PVC coated to achieve outer dia. not less than 4 mm , straining bolts, etc. including provission of binding wireThe mesh wire a of the fabric shall be manufactured from ISI marked galvanised steel confirming to IS - 280:2006 (4th revision).The Kuncled ends should be of at least 50% of the sixe of the square mesh. The wires used in fencing should be long lasting and resistance to corrosion and testing criteria fullfill the requirement as per IS 1161:1998 complete all as specified and directed. |
| 14 | M & L for 10mm dia round bar, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 15 | S&F mild steel bolt having dia of neck exc 16mm but not exc 20mm purpose made with hexagonal or square head one end and screwed the other or screwed both ends each screwed end to be fitted with washer and one hexagonal or square nut n.exc 5 cm long complete all as specified and directed. |
| 16 | M&L for preparation of surfaces of steel and iron of any description over 10cm in width or girth not other wise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 17 | M&L for prepration of new plastered surfaces and applying two coats of cement based paint on walls complete all as spd and directed. |
| 18 | Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed |
| 19 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose complete all as specified and directed. |
| 20 | S&F 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or in weep holes etc complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |