| 1 | Demolition of Brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as sepcified and directed. |
| 2 | Demolition of cement concrete reinforced as in chajja & similar suspended work (other than ground floor) complete all as specified and directed. |
| 3 | Demolition of cement concrete as in ground floors and pavings not exceeding 15 cm thick below or above ground level (unreinforced) complete all as specified and directed. |
| 4 | Excavating over areas in soft/loose soil, n exc 1.5 m deep and getting out, complete all as specified and as directed. |
| 5 | Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. |
| 6 | All as per BOQ Item No 5.00 here-in-before but of depth exc 1.5m and not exceeding 3.00 mtrs complete all as specified. |
| 7 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed. |
| 8 | Removing excavated material in soft/loose soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point, complete all as specified and as directed. |
| 9 | M&L for pavings, with mix of fly ash, clinker & stone dust in the proportion of 1:3:6 (ie 10% fly ash, 30% clinker and 60% stone dust ) laying in layers n. exc 10cm thick, watering, ramming and compacted with hand/power roller 8 to 12 tonn roller to required camber and gradient complete all as directed by Engineer-in-Charge. |
| 10 | Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5 m high from base complete all as specified and as directed. |
| 11 | M&L for hardcore of gauge not exceeding 63 mm of broken stone, deposited, spread and levelled layers not exceeding 15 cm thick, watered and rammed to a true surface, complete all as specified and directed. |
| 12 | M & L for PCC type D2 1:4:8 using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete complete all as specified and as directed. |
| 13 | M&L for M-25 Design mix using 20mm stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concret complete all as specified and directed. |
| 14 | M&L for RCC M-25 design mix 20mm graded aggregate for Walls, retaining walls, basement walls, ballast walls and the like; any thickness etc, complete all as specified and as directed. |
| 15 | M&L for RCC (Design mix), M-25 (using 20 mm graded aggregate) in slabs supported on walls, beams and columns, in roofs and in shelves and the like, complete all as specified and as directed. |
| 16 | M/L for Reinforcement cement concrete M-25 using 20 mm graded crushed stone aggregate as in column, pillars, piers, posts and struts etc all as specified and directed. |
| 17 | M&L for M-25 Design mix using 20mm stone aggregate Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed. |
| 18 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter complete all as specified and as directed. |
| 19 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of pillars, posts, struts, piers, columns and stanchions for fair finished surface of concrete Complete all as specified and directed. |
| 20 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. for fair finished surface of concrete, complete all as specified and directed. |
| 21 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc complete all as specified and as directed. |
| 22 | M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), for fair finished surface of concrete, all as specified and as directed. |
| 23 | M&L for fly ash brick old size straight or curved on plan exc 6 mtr mean radius built in CM 1:4 ,including demolition of brick work built in cement mortar including all quoins, arches, pillar etc all as specified and directed. |
| 24 | M&L for Rendering 15 mm thick cement plaster in CM 1:4 on fair faces of brick/concrete surfaces finished fair and even, mixed wth water proofing compound admixture (if directed) as per manufacturer's instruction, complete all as specified and directed.Note :- WPC will measuered and paid separatly under relevant item of schedule. |
| 25 | Supply only liquird water proofing compound complete all as specified complete all as specified and as directed. |
| 26 | Material & Labour for applying and making brick design fort with Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm including 2mm thick wall care putty over new surfaces complete all as specified and directed. |
| 27 | M&L Mild steel TMT bars 10 mm dia & over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified. |
| 28 | S&F TMT reinforcement bar, conforming to Fe-500, 6mm to 8mm dia cut to length , bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire ( annealed) not less than 0.9mm dia or securing with chips. |
| 29 | S&F TMT reinforcement bar, conforming to Fe-500, 5mm dia and upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as binding with and including mild steel wire (Annealed) not less than 0.9mm dia or securing with clips all as specified. |
| 30 | S & F rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces etc, complete drilled for fixing of steel sheeting or other covering, door etc to be prepared for sliding with and including either hooks and hinges, also fastening and fixing complete all as specified and directed. |
| 31 | M&L for preparing of new steel & iron surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enameled paint over a coat of Red oxide zinc chrome primer zinc chrome complete all as specified and as directed. |
| 32 | M&L 3 mm thick any colour ACP board ( Aluminium composite panel ), exterior grade (approved colour) fixed with aluminium frame /other similar frame work all as specified and as directed. |
| 33 | M & L for Providing, fabricating, and fixing maintenance-free and weatherproof 3D individual letters of the English alphabet, each with a height of 30 inches. The letters shall be fabricated using high-quality, UV-resistant cast acrylic sheets (min. 3mm–5mm thickness for fascia) with a 3-inch return (embossment) to create a 3D effect. The internal illumination shall be provided by energy-efficient, IP67/IP68 rated waterproof LED modules ensuring uniform front-lit glow without hotspots. The entire assembly shall be mounted on a sturdy base of 3mm thick Exterior Grade Aluminum Composite Panel (ACP) with a minimum 0.25mm coil thickness, fixed onto a concealed MS/GI square box pipe frame.The letters are to be securely screwed and fixed at any specified height or on the main gate. The work includes all necessary high-quality weatherproof wiring, IP67 rated power supply (SMPS), specialized fasteners, and finishing. The complete installation must be carried out to the entire satisfaction of the Engineer-in-Charge |
| 34 | All as per BOQ Item No 33.00 here-in-before but of individual numbers in English each with a height of 36 inches complete all as specified. |
| 35 | All as per BOQ Item No 33.00 here-in-before but of 3D formations/logos of overall size 30 inch x 30 inch complete all as specified. |
| 36 | M & L for Providing, fabricating, and fixing 3D formation signs of size 36 inch x 36 inch made of Stainless Steel (Grade 304) of specified thickness (min. 18/20 gauge). The letters shall be precision laser-cut with required returns (depth) to provide a 3D effect. The finish shall be Brush/Hairline or Mirror finish as per the approved design.The signage is to be securely mounted onto the existing MS Gate using concealed studs, spacers, or specialized SS fasteners to prevent galvanic corrosion between the SS signage and the MS base. The work includes template marking, buffing, polishing, and cleaning of the surface to ensure a seamless finish. All work shall be completed in all respects, including all lead and lift, to the entire satisfaction of the Engineer-in-Charge |
| 37 | M&L Reinforced concrete pipes, class NP2, 600 mm dia laid and jointed complete with collars complete all as specified and as directed. |
| 38 | M&L for 75 mm thick cement concrete M10 (Nominal Mix) with 40mm graded crushed aggregate finished even and fair laid to a slope of 1 in 12, laid in alternate bays, each bay not exceeding 3 m length with joint filled with bituminous mastic filling comprising a mixture of 1 part of heated Industrial bitumen 85/25 grade and two parts of heated sand as in plinth protection complete all as specified and as directed. |
| 39 | M&L for Soling (or sub base) of 150 mm thickness with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber, complete all as specified and as directed. |
| 40 | M&L for 15 cm thick (compacted thickness) WBM, using Granite, trap or basalt, of each layer 7.5cm with coarse aggregates of grading 2 (63 to 40mm size) spread, each layer rolled and consolidated seperately to gradient and camber required, complete all as specified and as directed. |
| 41 | M&L for preparing surfaces by brushing with wire brushes for removing caked mud etc. sweeping with brooms finally fanning the cleaned surface with gunny bags to remove all loose dirt etc, complete all as specified and as directed. |
| 42 | Material & Labour for 50mm sand filling under floors or in foundations including watering and consolidation, complete all as specified and directed. |
| 43 | Material & Labour for machine pressed precast concrete interlocking paver block, prepolished any shape and size confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade, with grey cement & no pigment complete all as specified and directed. |
| 44 | M&L for Forming Construction joint Grade B 30mm deep x 10mm wide filled with sealing compound, complete all as specified and as directed. |
| 45 | M&L for Forming Contraction (Dummy) joints Grade B 65mm deep x 10mm wide, filled with sealing compound, complete all as dpecified and as directed. |
| 46 | E/M PORTIONSupply, Laying and testing cable LT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with solid aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 4 core 10 sqmm. |
| 47 | Supply, Laying and testing cable LT XLPE sheathed,PVC insulated screened PVC bedded,galvanised steel strip of wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volt grade, laid in trenches/surface of wall/in GI pipe along with pole for connection to OH lines,including brass cable glands,clamps,etc of 4 core 25 sqmm. |
| 48 | M&L for Double Wall Corrugated (DWC) High density polyethylene pipes (HDPE) of 40mm dia laid in trenches for cable protection complete all as spcified and directed. |
| 49 | Supply and fix 3 core flexible 1.5 sqmm copper multistranded cable alongwith PVC conduit with connectors/lugs/thimble on both ends complete all as specified and directed. |
| 50 | Supply & Fixing sheet moulding compound junction box IP 66 weather proof for outdoor installation of size 205 x 255 x 112 with knockouts for cable entry suitable for terminating 2 Nos 4 x 10 to 25 Sqmm UG cable including MS clamp with nut and bolt and cable glandes - 2 Nos, and four way terminal all as specified and directed. Make : Hensel (Cat No. DK 2525 G) or equivalent. Please Enable Macros to View BoQ information |
| 51 | Supply & Fixing sheet moulding compound junction box IP 66 weather proof for outdoor installation of size 205 x 255 x 112 with knockouts for cable entry suitable for terminating 2 Nos 4 x 10 to 25 Sqmm UG cable including MS clamp with nut and bolt and cable glandes - 2 Nos, and four way terminal all as specified and directed. Make : Hensel (Cat No. DK 2525 G) or equivalent. Please Enable Macros to View BoQ information |