Complete Safety relief valve (SRV) as spare for one to one replacement of installed SRV of Make- M/s ASIAN INDUSTRIAL VALVES AND INSTRUMENTS, CHENNAI (ASVIN), Sr. No.- M181757. Required details are as below: Size (Inlet x Outlet)- 50NB x 80NB (2\\"x 3 \\") Flanged ANSI B16.5, 150# RF x 150# RF Required Flow- 1800 Kg./ hour Calculated orifice area - 0.533 Sq. inches Selected orifice area - 0.785 Sq. inches Orifice Designation- ' H ' Lifting Type- Full Lift, Bonnet Type- Bolted Closed, Screwed cap, Plain Lever, Metal to metal seated, with test lever, MOC as per drawing no.- 18-SRV-102 R3 with Cap & test gag. Confirming the ASME Sec. VIII-Div.1/API 520 & 527 Process Fluid- Saturated Steam Back pressure- ATM. Set Pressure- 9.5 Kg/Cm2 (a) Operating/Relieving temp.- 170 / 177 Degree C. Testing requirement as per given specification.
Complete Safety relief valve (SRV) as spare for one to one replacement of installed SRV of Make- M/s ASIAN INDUSTRIAL VALVES AND INSTRUMENTS, CHENNAI (ASVIN), Sr. No.- M181757. Required details are as below: Size (Inlet x Outlet)- 50NB x 80NB (2\\"x 3 \\") Flanged ANSI B16.5, 150# RF x 150# RF Required Flow- 1800 Kg./ hour Calculated orifice area - 0.533 Sq. inches Selected orifice area - 0.785 Sq. inches Orifice Designation- ' H ' Lifting Type- Full Lift, Bonnet Type- Bolted Closed, Screwed cap, Plain Lever, Metal to metal seated, with test lever, MOC as per drawing no.- 18-SRV-102 R3 with Cap & test gag. Confirming the ASME Sec. VIII-Div.1/API 520 & 527 Process Fluid- Saturated Steam Back pressure- ATM. Set Pressure- 9.5 Kg/Cm2 (a) Operating/Relieving temp.- 170 / 177 Degree C. Testing requirement as per given specification.
2
Complete Safety relief valve (SRV) as spare for one to one replacement of installed SRV of Make- M/s ASIAN INDUSTRIAL VALVES AND INSTRUMENTS, CHENNAI (ASVIN), Sr. No.- M181755. Required details are as below: Size (Inlet x Outlet)- 50NB x 80NB (2\\"x 3\\") Flanged ANSI B16.5, 150# RF x 150# RF Reduired Flow- 700 Kg./ hour Calculated orifice area - 0.789 Sq. inches Selected orifice area - 1.287 Sq. inches Orifice Designation- ' J ' Lifting Type- Full Lift, Bonnet Type- Bolted Closed, Screwed cap, Plain Lever, Metal to metal seated, with test lever, MOC as per drawing no.- 18-SRV-102 R3 with Cap & test gag. Confirming the ASME Sec. VIII-Div.1/API 520 & 527 Process Fluid- Steam Back pressure- ATM. Set Pressure- 2.5 Kg/Cm2 (a) Operating/Relieving temp.- 112 / 126 Degree C. Testing requirement as per given specification.
Complete Safety relief valve (SRV) as spare for one to one replacement of installed SRV of Make- M/s ASIAN INDUSTRIAL VALVES AND INSTRUMENTS, CHENNAI (ASVIN), Sr. No.- M181755. Required details are as below: Size (Inlet x Outlet)- 50NB x 80NB (2\\"x 3\\") Flanged ANSI B16.5, 150# RF x 150# RF Reduired Flow- 700 Kg./ hour Calculated orifice area - 0.789 Sq. inches Selected orifice area - 1.287 Sq. inches Orifice Designation- ' J ' Lifting Type- Full Lift, Bonnet Type- Bolted Closed, Screwed cap, Plain Lever, Metal to metal seated, with test lever, MOC as per drawing no.- 18-SRV-102 R3 with Cap & test gag. Confirming the ASME Sec. VIII-Div.1/API 520 & 527 Process Fluid- Steam Back pressure- ATM. Set Pressure- 2.5 Kg/Cm2 (a) Operating/Relieving temp.- 112 / 126 Degree C. Testing requirement as per given specification.
We takes all possible care for accurate & authentic tender information, however Users
are requested to refer Original source of Tender Notice / Tender Document published by
Tender Issuing Agency before taking any call regarding this tender.