Name of Work:- Day to Day Electrical Maintenance at Pocket-11 at Sector G7/G8, Narela.Sub Head : Comprehensive Maintenance of lifts installed at Pocket-11 at Sector G7/G8, Narela.
Sl. No.
Item Description
1
Annual comprehensive maintenance of 53 Nos. (16-Passengers), Schindler make lifts with 13 landing/openings with ARD at rated speed of 1.75 mtr./ second which includes routine, preventive and break down maintenance for a period of one year including repair / replacement of all worn out items, accessories and control equipments, defective parts with minimum down time as per inventory, terms & conditions enclosed etc. complete as required.
2
Annual comprehensive maintenance of 3 Nos. (16-Passengers), Schindler make lifts with 12 landing/openings with ARD at rated speed of 1.75 mtr./ second which includes routine, preventive and break down maintenance for a period of one year including repair / replacement of all worn out items, accessories and control equipments, defective parts with minimum down time as per inventory, terms & conditions enclosed etc. complete as required.
3
Annual comprehensive maintenance of 01 Nos. (13-Passengers), Schindler make lifts with 12 landing/openings with ARD at rated speed of 1.75 mtr./ second which includes routine, preventive and break down maintenance for a period of one year including repair / replacement of all worn out items, accessories and control equipments, defective parts with minimum down time as per inventory, terms & conditions enclosed etc. complete as required.
4
Annual comprehensive maintenance of 1 Nos. (13-Passengers), Schindler make lifts with 13 landing/openings with ARD at rated speed of 1.75 mtr./ second which includes routine, preventive and break down maintenance for a period of one year including repair / replacement of all worn out items, accessories and control equipments, defective parts with minimum down time as per inventory, terms & conditions enclosed etc. complete as required.
5
supplying & replacement of following Non Working, damaged & missing Lift parts for lift equipment no 10908820 & 10908823 to keep lifts functional:Landing door panel Qty 2.00 Kit IDN Safety gear act. m. TL SA-GED1X Qty 2.00 PCBA CANCP 211.Q sus.57618362 Qty 2.00 PowSup_230VAC_26VDC(HF150W SDR 26 G) Qty 2.00 PCBA COPKGL 51.Q Qty 8.00 PCBA COPKGL 31.Q Qty 8.00 Module VVVF5+ drive T2L/C2 EU/NA Qty 2.00 SDIC53.Q anti-sulphur resistors Qty 2.00 Batt_VRLA_12V_12Ah_HD_F2_40C_2K Qty 4.00 Wiring LDU-VF 6mm2 w. AES IND Bionic 5.4 Qty 4.00 Inverter 24VDC-230VAC 800W Qty 2.00 COP GS 120-IN 9/6 M without VCA Qty 2.00 Set motor VVVF Qty 2.00 Travelling Base Cable HQ <= 60 CCL Qty 130.00 LOP GS 100 M-1WSF ASSEMBLED (COMPLETE) Qty 20.00
6
supplying & replacement of following Non Working, damaged & missing Lift parts for lift equipment no 10908826 & 10908828 to keep lifts functional:LOP cable 1.5mm2, L=3600mm Qty.20.00 Nos.SKS extension Bionic 5 L=3800 Qty 10.00 IND Intercom (3-way) Harness cable Qty 6.00 CAT 6 flat Travelling cable Qty 120.00 PCBA SCPU1.Q + SW 9.85,anti-sulphur res. Qty 2.00SDIC53.Q anti-sulphur resistors Qty 2.00Module VVVF5+ drive T2L/C2 EU/NA Qty 2.00Set motor VVVF Qty 2.00 PCBA CANCP 211.Q sus.57618362 Qty 2.00 Cross Flow Fan / ULF2-1042CS III Qty 2.00Landing door panel Qty 2.00 2.5 sq. mm 4 core cu cable for SPD to JH Qty 4.00 2.5 sq. mm 2 core cu cable for TAS I/P Qty 4.00Inverter 24VDC-230VAC 800W Qty 2.00Batt_VRLA_12V_12Ah_HD_F2_40C_2K Qty 4.00PowSup_230VAC_26VDC(HF150W SDR 26 G) Qty 2.00 Bi- Stable magnet switch with harness Qty 4.00 10 sq. mm 4 core cu cable for SPD to JH Qty 4.00 1 sq. mm 2 core cu cable for SPD alarm Qty 4.00 Kit LSC154 DO V15/FEC T2L/T2R Qty 2.00 Travelling Base Cable HQ <= 60 CCL Qty 120.00 LOP GS 100 M-1WSF ASSEMBLED (COMPLETE) Qty 20.00 COP GS 120-IN 9/6 M without VCA Qty 2.00
7
supplying & replacement of following Non Working, damaged & missing Lift parts for lift equipment no 10908876 & 10908877 to keep lifts functional:Sup. Mod. TL IND 32A w. AES BIC5 Qty 2.00 Base Module TL IND with AES Bionic 5.4 Qty 2.00 LOP cable 1.5mm2, L=3600mm Qty 2.00 PCBA CANCP 211.Q sus.57618362 Qty 2.00 IND Intercom (3-way) Harness cable Qty 6.00 SKS extension Bionic 5 L=3800 Qty 10.00 CAT 6 flat Travelling cable Qty 120.00 SDIC53.Q anti-sulphur resistors Qty 2.00 Module VVVF5+ drive T2L/C2 EU/NA Qty 2.00Set motor VVVF Qty 2.00 Cross Flow Fan / ULF2-1042CS III Qty 2.002.5 sq. mm 4 core cu cable for SPD to JH Qty 8.00 Qty2.5 sq. mm 4 core cu cable for SPD to JH Qty 8.002.5 sq. mm 2 core cu cable for TAS I/P Qty 8.00Batt_VRLA_12V_12Ah_HD_F2_40C_2K Qty 4.00Bi- Stable magnet switch with harness Qty 4.00 10 sq. mm 4 core cu cable for SPD to JH Qty 8.00 COP GS 120-IN 9/6 M without VCA Qty 2.00 Travelling Base Cable HQ <= 60 CCL Qty 130.00 Kit LSC154 DO V15/FEC T2L/T2R Qty 2.00 PCBA SCPU1.Q + SW 9.85,anti-sulphur res. Qty 2.00 Please Enable Macros to View BoQ information