| 1 | FR-Grade Decorative Wall Panelling :- Providing and fixing in position decorative wall panelling, comprising a sub-framework of 19mm thick BWP (Boiling Water Proof) plywood strips, arranged in a grid of 600mm x 600mm. The framework shall be treated with two coats of approved Fire Retardant (FR) chemical/paint and securely anchored to the wall/RCC surface using dash fasteners and screws, ensuring the surface is perfectly plumb and level.The framework shall be covered with 12mm thick BWP plywood (conforming to IS:710), bonded with Fire Retardant (FR) grade synthetic resin adhesive. The final visible surface shall be finished with 1.0mm thick Fire Retardant (FR) Textured Laminate (e.g., Greenlam, Merino, or equivalent) of approved shade and texture. |
| 2 | Decorative Panelling with 1.0mm Textured Laminate : Providing and fixing decorative panelling to walls or surfaces, consisting of 12mm thick BWP (Boiling Water Proof) grade plywood (conforming to IS:710). The plywood shall be fixed over a pre-installed framework using headless nails and approved synthetic resin adhesive, ensuring the surface is perfectly true to line and level.The face shall be finished with 1.0mm thick textured laminate of approved shade, make, and design. The laminate is to be bonded using high-strength FR-grade (Fire Retardant) adhesive, applied uniformly to ensure a bubble-free finish. |
| 3 | Providing and fixing decorative panelling on walls/partitions/ceilings, comprising 1.0mm thick textured laminate of approved shade, make, and design and FR grade. The laminate shall be bonded over existing using high-quality, heat-resistant synthetic resin adhesive (e.g., Fevicol SH or equivalent). complete and as all specified and directed. |
| 4 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete and as all specified and directed. |
| 5 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer on new steel surfaces of any description over 10cm in width or girth not otherwise described incl preparation of surfaces complete and as all specified and directed. |
| 6 | Dismantling, floor, hearth or wall tiling /terrazo including cement mortar bedding but not backing and removing rubbish off the premises complete and as all specified and directed. |
| 7 | M & L for Providing and laying floating-type laminated wooden flooring of 8mm thickness, using HDF (High-Density Fiberboard) core (conforming to EN 13329 standards or equivalent). The flooring shall have an AC3/AC4 wear rating as per traffic requirements, with a melamine-impregnated decorative surface and a balancing film on the underside.The installation shall include a sub-layer of 2mm to 3mm thick non-crosslinked polyethylene (PE) foam or similar approved padding material to act as a moisture barrier and acoustic cushion. The planks shall be joined using a glueless \\"Click\\" interlocking system, ensuring tight, seamless joints. |
| 8 | Supplying and fixing matching wooden skirting or beading of approved shade and texture to complement the HDF laminated flooring. The skirting shall be made of HDF or moisture-resistant MDF (typically 60mm to 75mm in height and 12mm to 15mm in thickness) with a factory-laminated finish.The skirting shall be fixed along the periphery of the walls to cover the mandatory expansion gaps of the wooden flooring. Installation is to be done using concealed clips, headless pins, or high-strength adhesive as per the manufacturer’s specifications, ensuring mitered joints at all internal and external corners for a neat, seamless appearance. |
| 9 | Supplying and fixing in repairs high-grade 0° Degree (Full Overlay) auto-concealed hinges with an integrated soft-closing mechanism (hydraulic buffer) for cupboard/cabinet shutters. The hinges shall be manufactured from high-tensile Mild Steel with a Bright Nickel-Plated finish or Electro-Galvanized coating to ensure superior corrosion resistance and durability. |
| 10 | S&F Powder coated aluminium (miimum thickness of powder coating 50 micron) work for doors, windows, ventilators frame and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per the directions of Engineer-in-Charge |
| 11 | M & L for Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads all as specified and as directed. |
| 12 | S&F Sheet glass 4.0 mm thick, ordinary quality & glazing with oil putty in square but n.exc 0.5 sq.m in each pane complete all as specified and as directed. |
| 13 | S&F in repairs brass 4-levers mortice lock, vertical type , size 100mm complete all as spcified and as directed. |
| 14 | Supplying and fixing high-performance Solar Control Film, 25-micron thickness, Reflective Type, to the internal surface of existing glass panes. The film shall be designed to provide significant heat reduction, UV protection, and glare control, with a scratch-resistant hard coat for durability.Note : The installation must be carried out in strict accordance with the manufacturer's instructions using a specialized \\"wet-application\\" method. This includes thorough chemical cleaning of the glass surface to remove all dust, grease, and impurities, followed by precision cutting and squeegeeing to ensure a perfectly smooth finish, free from air bubbles, creases, water pockets, or edge peeling. |
| 15 | S&F in repairs anodised aluminium snap grid frame work for false ceiling, size of grid 605 x 605mm, hangers 4 mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means ceilings cleats made out od GI flat 40x3 mm size 60 mm long and expansion hold fastners 12.5 mm dia including 4 mm thick non asbestos fibre cement building boards fixed or laid/inserted to timber/GI/Aluminium frame work, complete all as specifed and as directed. |
| 16 | Demolition of Cement Concrete (un-reinforced) of any description and in any position not otherwise specifically provided for all as specified and as directed. |
| 17 | M&L 40 mm thick PCC 1:2:4 type B-0 (using 12.50 mm graded crushed stone aggregate) as in roof padding, finished fair and even without using extra cement for roof surfaces complete all as specified and as directed. |
| 18 | Material and labour for rendering 5 mm thick on fair faces on roof surfaces of concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement, complete all as specified and as directed. |
| 19 | M & L for providing water proofing treatment with a layer of APP based polymeric membrane, 3 mm thick (minimum), weighing not less than 3.60 kg/Sqm reinforced with polymer non woven fabric (weighing not less than 160 gm/ Sqm) shall be applied over one coat of cold bituminious primer @ 0.40 ltr/ Sqm ( membrane shall be laid using butane torch and sealing all joints etc, complete all as specified and directed .( Note: The overlaps shall be of minimum 75 mm on longitudinal direction and 100 mm on transverse direction) complete all as specified and directed. |
| 20 | M & L for one coat of aluminium paint over APP membrane, complete all as specified and as directed. |
| 21 | M & L for screed or bedding layer 15mm thick in cement mortar 1:6 laying floor finishes complete all as specified and as directed. |
| 22 | M&L for Vitrified Ceramic tiles fully body double charged 8-9 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 23 | M&L for Vitrified Ceramic tiles 8-9 mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 24 | Taking down carefully aluminium/Copper conductor point wiring (light , fan, socket or powr) complete including fittings such as switches, ceiling rose, pendents, regulators sockets etc and removing (except those to be reused shall be kept in safe custody at the site) and making good disturbed surfaces of walls, floors etc tomatch with the existing completeall as specified and directed. Please Enable Macros to View BoQ information |
| 25 | Taking down carefully aluminium/Copper conductor point wiring (light , fan, socket or powr) complete including fittings such as switches, ceiling rose, pendents, regulators sockets etc and removing (except those to be reused shall be kept in safe custody at the site) and making good disturbed surfaces of walls, floors etc tomatch with the existing completeall as specified and directed. Please Enable Macros to View BoQ information |