| Sl. No. | Item Description |
| 1 | Taking down old and unserviceable alumunium point wiring in batten/ conduit and make good the disturbed surface to match the existing surface, complete all as specified and directed by Engr-in-charge. |
| 2 | Taking down old and unserviceable submain wiring any size of two core including earth wire complete including batten/ conduit and make good the disturbed surface to match the existing surface complete all as directed by Engr-in-charge. |
| 3 | Taking down old and unserviceable, distribution board any type including/ sheet metal enclosures, after removing all connection and make good the disturbed surface all as directed by Engr-in-chanrge |
| 4 | M&L for Point wiring using FRLSLH PVC insulated unsheathed, multistranded copper conductor cable 1.5 sqmm drawn through and including PVC conduit of min 20 mm dia by Cutting chases for conduits and sinking's for boxes and making good to walls, floors etc fo concealed conduit wiring with modular flush box metal of GI sheet minimum 1.8 mm thick with earth terminal for safety, flush metal GI box of required modules as per site requirement and modular cover plate with support frame white in colour of required modules, 3mm thick including all fittings i.e. tees, bands and junction boxes, screws etc. complete for one light/fan/bulb point controlled by one switch 6 Amps one way using cable (1.5 Sq mm for phase and neutral and 1.5 sq mm earthing) Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. Note:- (a) wiring shall be done by using colour coding (b) Earth wire shall be of green colour. |
| 5 | All as item No 4 above One 3 pin socket outlet, 5/6 Amp socket outlet on same board with other switches. |
| 6 | All as per item No 4 above but One 3 pin socket outlet, 5/6 Amp socket outlet on independent board. |
| 7 | All as per item No 4 above but One light point controlled by two 2-way switches, with cables 1.5 sq. mm size. |
| 8 | As per item No 4 above but One bell / buzzer point controlled by one bell push on independent board complete all as specified and directed. |
| 9 | Supply and fixing socket, 6A - 2/3 pin combined 2 module, fabio series 6 Amps 3 pin unversal socket with child safety shutter, Shrouded terminals compatible with all standard mobile chargers, ISI marked for the same board complete all as specified and directed. |
| 10 | Supply and fixing modular switch 1 way 6A, 1 module modular Switch fabio classic white series/ Switch fabio classic white with indicator, ISI marked switch complete all as specified and directed. |
| 11 | Supply and fixing modular switch 2 way 6A, 1 module modular Switch fabio classic white series/ Switch fabio classic white with indicator, ISI marked switch complete all as specified and directed. |
| 12 | Supply and fixing modular bell/buzzer switch 1 way 6A, 1 module modular Switch fabio classic white series/ Switch fabio classic white with indicator, ISI marked switch complete all as specified and directed. |
| 13 | M & L for point wiring to one 3 pin 15/16 Amps socket outlet independent switch board, using FRLS-H PVC insulated unsheathed, multistranded copper conductor cable 2.5 sqmm drawn through and including PVC conduit of min 20 mm dia by Cutting chases for conduits and sinking's for boxes and making good to walls, floors etc for concealed conduit wiring with modular flush box metal of GI sheet minimum 1.2 mm thick with earth terminal for safety, flush metal GI box of required modules as per site requirement and modular cover plate with support frame white in colour of required modules, 3mm thick including all fittings i.e. tees, bands and junction boxes, screws etc. complete for power point controlled with cables, 2.5 sq. mm size, Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. (2.5 Sqmm for Phase and neutral and 2.5 Sqmm for earthing) |
| 14 | Supply and fixing in repair Socket 6/16A - 2/3 pin combined 2 module,(Fabio classic white) shuttered socket (heavy duty) 3 pin unversal socket with child safety shutter, Shrouded terminals compatible 2 ton AC and 3.5 KW geyser, ISI marked for the same board complete all as specified and directed. |
| 15 | Supply and fixing in repair modular Switch fabio classic white series/ Switch fabio classic white with indicator, ISI marked 16 Amps One Way switch complete all as specified and directed. |
| 16 | M & L for one point wiring with PVC insulated un-sheathed cable with stranded copper conductor FR-LS conforming to IS : 694 of size 1.5 Sq mm single core, including one No. 1.5 Sq mm single core PVC insulated un-sheathed copper cable FR-LS as continuous earth wire drawn in and including conduit of required size ISI marked medium grade white colour with all accessories of same grade concealed on wall/ceiling including terminated in to Cast iron/pressed steel terminal box 60mm deep of required size made out of 2mm thick MS sheet duly painted both sides with 3 mm thick plastic laminated sheet top cover fixed with brass screw & cup washers for mounting switches, fan regulators etc for one light, fan controlled by one 5 Amp switch one way complete all as specified and as directed |
| 17 | As per item No 16 above but One 3 pin 5 amps socket outlet point on same board complete all as specified and directed. |
| 18 | As per item No 16 above but One 3 pin 5 amps socket outlet point on independent board complete all as specified and directed. |
| 19 | All as per item No 16 above but One light point controlled by two 2-way switches, with cables 1.5 sq. mm size. |
| 20 | All as per item No 16 above but wiring with cable 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch. |
| 21 | As per item No 16 above but One bell / buzzer point controlled by one bell push on independent board complete all as specified and directed. |
| 22 | Supply and fixing in repair Bell push,flush type 5 Amps complete all as specified and directed. |
| 23 | Supply and fixing buzzer dingdong AC 230 Volts, single pole, 50 Hz complete all as specified and directed. |
| 24 | Supply and fixing in repair Socket outlet 2 in 1, 3 pin, 5 amp flush type ISI marked for the same board complete all as specified and directed. |
| 25 | Supply and fixing in repairs switch socket combination 5 Amps 2 in 1 flush type multipurposes for independent board complete all as specified and directed. |
| 26 | Supply and fixing in repairs switch socket combination 2 in 1, 3 pin 5 and 15 Amp flush type multipurposes for independent board complete all as specified and directed. |
| 27 | Material & Labour for point wiring for one light / Fan point controlled by one, one way switch complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable 1100 volts grade ISI marked drawn through and including PVC casing & caping on surface of wall, not less than 25mm width confirming to IS 9537 (Part-III) 1983, including all accessories like bend, tees, junction boxes etc., 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, fire retardant low smoke cable as a earth wire connected to common earth dolly, etc and including sunken type pressed steel terminal box with 1.8 mm wall thickness, of suitable size for flush type switch with cover plate, cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate complete. Note - Colour code of cable Phase-Red Neutral- Black and Earth -Green) |
| 28 | As per item No 27 above but One 3 pin 5 amps socket outlet point on same board complete all as specified and directed. |
| 29 | As per item No 27 above but One 3 pin 5 amps socket outlet point on independent board complete all as specified and directed. |
| 30 | All as per item No 27 above but wiring with cable 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch. |
| 31 | As per item No 27 above but One bell / buzzer point controlled by one bell push on independent board complete all as specified and directed. |
| 32 | Supply and fixing in repair Bell push,flush type 5 Amps complete all as specified and directed. |
| 33 | Supply and fixing buzzer dingdong AC 230 Volts, single pole, 50 Hz complete all as specified and directed. |
| 34 | Supply and fixing in repair Socket outlet 2 in 1, 3 pin, 5 amp flush type ISI marked for the same board complete all as specified and directed. |
| 35 | Supply and fixing in repairs switch socket combination 5 Amps 2 in 1 flush type multipurposes for independent board complete all as specified and directed. |
| 36 | Supply and fixing in repair Switch piano, flush type single pole, one way 5 Amps 3 pin, ISI marked for the same board complete all as specified and directed. |
| 37 | Supply and fixing in repair Socket outlet 3 pin, 15 Amp, flush type , ISI marked complete all as specified and directed. |
| 38 | Supply and fixing in repair Switch piano 15 Amp, flush type single pole, ISI marked 16 AX Amps One Way switch omplete all as specified and directed. |
| 39 | Supply and fixing in repair Ceiling rose, 3 phase/PVC/polycarbonate, isolated body type complete all as specified and directed. |
| 40 | Supply and fixing in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd at site complete all as per specified and directed. |
| 41 | Supply & Fixing in repair only LED lights fitting 22 W LED 6000K (4Ft),(Warm/ Warm White) 220V,AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 42 | Supply and fixing in repair LED light fitting 2 feet, 10 watt 220 V AC (Warm/ White) decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete |
| 43 | M&L for sub main wiring power/circuit using PVC insulated unsheathed, stranded copper conductor cable 2 Single core of size 4 Sqmm, earth continuity conductor of size 4.0 Sqmm to be drawn through and including PVC conduit 20mm dia medium Grade concealed in walls/roof/floors including taking down the old submain wiring all as directed by Engineer in Charge.Notes:- (i) Two wires of 4 sqmm and one wire of 4.0 sqmm and one run of PVC conduit shall be measured as one unit. |
| 44 | M&L for Sub Main wiring complete with copper conductor, multi stranded, FRLS, PVC insulated and sheathed, 6 Sq mm, two run 1100 volts grade, incl drawn through PVC suitable size counduit and 6 Sqmm single run for earthing. |
| 45 | M&L for Sub Main wiring complete with copper conductor, multi stranded, FRLS, PVC insulated and sheathed, 10 Sq mm, two run 1100 volts grade, incl drawn through PVC suitable size counduit and 10 Sqmm single run for earthing. |
| 46 | Supply and fixing in repair modular 5 stepped type electronic fan regulator- 2M 100W laser marking as reqd at site complete all as per specified and directed. |
| 47 | Supply and fixing in repair round shape slim fit down light LED 15 Watt round recess (Warm/ Warm White) 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size completecomplete all as specified and directed. |
| 48 | Supply and fixing in repair square shape 36 watt 220 volts AC recessed mounting type low depth aesthetically designed LED 2x2 feet flat (Warm/ Warm White) panels, with high efficiency PMMA diffuser soft glare free light (Warm/ Warm White) suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 49 | Supply and fixing in repair Sheet Metal enclosure double door for DBs when MCBs to be used TPN-4 Way with 200 Amp rated bus bar complete all as specified and directed. |
| 50 | Supply and fixing in repair Sheet Metal enclosure double door for DBs when MCBs to be used SPN- 8 Way with 200 Amp rated bus bar complete all as specified and directed. |
| 51 | All as per Item No 37 above but SPN - 12 Way complete all as specified and directed. |
| 52 | Supply and fixing in repairs Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp, 240 Volts complete all as specified and directed. |
| 53 | Supply and fixing in repair 415V 10KA 'B' curve miniature circuit breaker (MCB) TPN and current carrying capacity 63 Amp in the DB complete with connection testing and commissioning . |
| 54 | Supply and fixing in repair amp rating 240V, 10KA 'B'curve miniature circuit breaker (MCB) SPN and current carrying capacity 40 Amps in the MCB DB complete with connection testing and commissioning |
| 55 | Supply and fixing repair amp rating 240V, 10KA 'B' curve miniature circuit breaker (MCB) SP and current carrying capacity 5-32 Amps in the MCB DB complete with connection testing and commissioning |
| 56 | Supply and fixing socket out let 5 Amps 3 pin flush type for the same board complete all as specified and directed. |
| 57 | Supply and fixing in repairs witch socket combination 5 Amps 2 in 1 flush type multipurposes for independent board complete all as specified and directed |
| 58 | Supply and fixing in repair switch socket combination out let 5/16 Amps 5 in 1 flush type complete all as specified and directed. |
| 59 | Supply and fixing in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd at site complete all as per specified and directed. |
| 60 | Supply and fixing in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 61 | Supply and fixing in repair Bell push,flush type 5 Amps complete all as specified and directed. |
| 62 | Supply & fix in repair Bulk head fitting energy saving 10 W LED with opal diffuser light fitting including necessary fixing arrangements including LED bulb complete all as specified and directed. |
| 63 | Renewal of Earthing complete with galvanized street earth plate electrode 600x600x6mm thick buried directly in ground (earth plate not less than 2.25mtr deep below normal ground level) with top edge of the plate not less then 1.50 mtr. below the normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washer of galvanized iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified and testing on completion including the material and labour for :-(a) Excavation and earth work or drilling hole for electrode in any type of soil (b) PCC pit in cement concrete 1:2:4 TYPE B-1 (.c) CI cover with suitable handle (d) Funnel with watering pipe of GI 20mm nominal bore medium grade and Aluminum lugs etc all as specified.(e) 15mm nominal bore medium grade GI protection pipe up to 7.50 meter long for protection of earthing lead.(f) Requisite quantity of charcoal and common salt (g) Connection to earthing test point and testing on completion. |
| 64 | Taking down ceiling fan any size or sweep after disconnecting, dismantling and removal to trade workshop for repair, complete all as specified and directed. |
| 65 | M& L for Opening the unserviceable/burnt ceiling fan 1200/1400 mm sweep and cutting of old burnt copper winding and rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, reassembling, testing and connecting for satisfactory run, complete all as specified and directed. |
| 66 | Supply and replacing of Ball bearing of the ceiling fan (any sweep) as per existing size incl greasing/oiling, complete all as specified and directed. Make:- SKF/ NBC or Equivalent |
| 67 | Supply and replacenment gun metal bushes of surface size for ceiling fan/ceiling fan incl necessary mechanical work, complete all as specified and directed. |
| 68 | Supply and replacing of cord cable, three core 0.5 Sqmm PVC insulated copper conductor cable for connecting ceiling fan, complete all as specified and directed. |
| 69 | Supply and Fix in repair Capacitor of of 3.15 MFD for ceiling fan, complete all as specified and directed. |
| 70 | Supply and fixing in replacement ceiling fan blade set of three heavy duty suitable for 1200/1400mm sweep of suitable approved make as direcetd by Engr-in-Charge. |
| 71 | Supply and Fix in replacement of PVC canopy for ceiling fan 1200/1400mm sweep complete for various makes/model of fan, complete all as specified and directed. |
| 72 | Supply and fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) |
| 73 | Disconnecting and taking down exhaust fan and blades any size or sweep after dismantling and removal to trade workshop for repair, complete all as specified and directed. |
| 74 | M&L for Strip opening and cutting of old burnt copper winding of exhaust fan and rewinding of exhaust fan motor of sweep 450mm with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnish, re-assembling, testing and connecting for satisfactory run, complete all as specified and directed. |
| 75 | All as per srl item No. 74 here-in-before, but of 300mm sweep. |
| 76 | Supply and Fix in repair Capacitor of 4 Mfd for exhaust fan, complete all as specified and directed. |
| 77 | Supply and fixing in replacement of Ball bearing of exhaust fan of any size/make as per the existing, complete all as specified and directed. Make: SKF/NBC or equivalent. |
| 78 | Painting the exhaust fan including louvers of size 300/450mm sweep with two coats of synthetic enamel paint after cleaning and making the surface of oil/dust free, complete all as specified and directed. |
| 79 | Servicing of Geyser by disconnecting the electric and water supply connections, dismantling the geysers of any size, type & capacity and opening the top and bottom cover, thermostat, heating element, safety valve, vent pipe, separating inner & outer tank, removing glass wool insulation complete and keeping aside for re-use after de-scaling of inner tank by liquid chemical and with pressure water jet and assembling back the geyser including re-installation on wall with studs, nuts & bolts complete and testing after reconnecting electric and water connections, complete all as specified and directed. Note- Spares will be measured and seperately under respictive items of Sch 'A'. |
| 80 | Supply and fiixing in replacement of Heating element for geyser of cap 1.5KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/ Bajaj/ Havells |
| 81 | Supply and fixing in replacement of Heating element for geyser of cap 2.0KW, AC 230 Volts, 50 Hz (as per sample), complete all as specified and directed. Make:- Micron/Bajaj/havells |
| 82 | Supply and fixing in replacement of Thermostat for Geyser of capacity 25/35/50 ltr (long size) with temperature setting adjustment range from 40 to 85°C, ISI Marked, complete all as specified and directed. Make:- Philips/ Bajaj/ Venus |
| 83 | Supply and fixing in replacement of Geyser Syphon Assembly Set suitable for 25 ltr capacity geyser, fixed in replacement, complete all as specified and directed. |
| 84 | All as per item Srl No. 83 above but for 35 Ltr capacity. |
| 85 | All as per item Srl No. 83 above but for 50 Ltr capacity. |
| 86 | Supply and fixing in replacement of Rubber gasket for water heater/Geyser storage type of any capacity fixed, in replacement and suitable as per the existing, complete all as specified and directed |
| 87 | Supply and fixing in replacement of PVC insulated sheathed three core copper conductor flexible wire of size 2.5 Sqmm for electric connection of geyser, complete all as specified and directed. |
| 88 | Supply and fixing of Sheet Metal Enclosure with socket, plug top and MCBs single pole and neutral enclosures with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 Volts, complete all as specified and directed. |
| 89 | Supply and Fixing in replacement of safety valve for geyser of 25/35/50 litre capacity, complete all as specified and directed |
| 90 | Supply and and fixing in replacement of non return valve 15mm dia for geyser of 25/50 litre capacity, complete all as specified and directed. |
| 91 | Supply and fixing in replacement of heavy duty PVC connector 600mm long 15mm dia with PTMT nut for geyser of 25/35/50 litre capacity, complete all as specified and directed. Make- Prayag or equivalent |
| 92 | Disconnecting and taking out geyser of capacity 25 litre and replacement of copper/SS inner tank and refilling of glass wool, refixing, connecting and testing, complete all as specified and directed. |
| 93 | All as per item Srl No. 92 above but for 35 Ltr capacity. |
| 94 | All as per item Srl No. 92 above but for 50 Ltr capacity. |
| 95 | Preparation of surface of Geyser of capacity 25/35/50 Ltr by scarping, removing old paint etc and applying two coats of synthetic enamel paint over one coat of red oxide primer,complete all as specified and directed. |
| 96 | Supply and fixing inreplacement of geyser Bolt 100 mm Long with nut & washers, complete all as specified and directed. |
| 97 | Taking out the burnt/ unserviceable compressor from the refrigerator of 165 to 200 ltr capacity and supply & fixing IN replacement of the same as per the existing complete all as specified and directed. |
| 98 | Servicing and overhauling of refrigerator of 165 to 200 ltr capacity of various make and model incl transporting to workshop & back complete. |
| 99 | Supply and fixing in Replacement of thermostat for refrigerator of 165 to 200 ltr capacity. |
| 100 | Supply and fixing in Replacement of thermal relay for refrigerator of 165 to 200 ltr capacity. |
| 101 | Charging refrigerant R134A and testing for proper cooling and leakage before charging of new refrigerant etire system will clean with nitrogen and check the leakage with leakage indicators complete for refrigerator of 165 to 200 ltr capacity all as specified and directed. |
| 102 | Taking out the burnt/ unserviceable compressor from the refrigerator of 210 to 335 ltr capacity and supply & fixing the same as per the existing complete all as specified and directed. |
| 103 | Servicing and overhauling of refrigerator of 210 to 335 ltr capacity of various make and model incl transporting to workshop & back complete. |
| 104 | Supply and fixing in Replacement of thermostat for refrigerator of 210 to 335 litre capacity. |
| 105 | Supply and fixing in Replacement of thermal relay for refrigerator of 210 to 335 litre capacity. |
| 106 | Supply and fixing in repair ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) |
| 107 | Taking out the burnt/ unserviceable compressor from the deep freezer of 210 to 400 ltr capacity and replacing & fixing the same as per the existing complete all as specified and directed. |
| 108 | Servicing and overhauling of deep freezer of 210 to 400 ltr capacity of various make and model incl transporting to workshop complete. |
| 109 | Supply and fixing in Replacement of thermostat for deep freezer of 210 to 400 litre capacity. |
| 110 | Supply and fixing in Replacement of thermal relay for deep freezer of 210 to 400 litre capacity. |
| 111 | Charging refrigerant R134A and testing for proper cooling and leakage before charging of new refrigerant etire system will clean with nitrogen and check the leakage with leakage indicators complete for Deep freezer of 210 to 400 ltr capacity all as specified and directed. |
| 112 | Taking down old unserviceable exhaust fan and deposited to E/M store and supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers. |
| 113 | Disconnecting the electric supply from the mains, transporting the window/split type air conditioner any capacity from original location to workshop to carry out the servicing complete and re-fixing at the original position after repairs and making the ACs fully functional and testing for satisfactory working, complete all as specified and directed. |
| 114 | Taking out old burnt/unserviceable compressor from the air conditioner any capacity and replacing new compressor the same as per the existing, re-fixing in position including testing for satisfactory working, complete all as specified and directed. |
| 115 | Charging refrigerant gas R22/R32/R410A required 60 to 120 PSI in any capacity window /Split type air conditioner complete including testing for satisfactory working after flushing out and cleaning the surface with nitrogen gas for checking the leakage, complete all as specified and directed. |
| 116 | Supply and fixing in replacing as per existing AC blower motor suitable for any capacity air conditioner, complete all as specified and directed. |
| 117 | Supply and fixing in replacing thermostat suitable for any capacity air conditioner, complete all as specified and directed. Make:- Ranutrol / Sriram / Hitech / Classic |
| 118 | Supply and fixing in replacement of sensor relay suitable for any capacity air conditioner, complete all as specified and directed. |
| 119 | Supply and fix in repair of running condenser 36 Mfd, complete all as directed. |
| 120 | Supply and fix in repair of starting condenser 100/120 Mfd, complete all as directed. |
| 121 | Repair to unserviceable/burnt stabilizer of 3 KVA to 5 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnishing, reassembling, replacement of knobs, LED's etc. and making fully functional on load as connected to Refrigerator/Deep freezer/AC, complete all specified and directed by Engr- in-charge. |
| 122 | All as per item Srl No. 121 above but for stablizer of 0.5/1 KVA capacity. |
| 123 | Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300m all as specified and directed. |
| 124 | Dismantling the complete fuel injector pump of water heating plant of various capacity upto 2000 ltrs, transporting to trade workshop for repairs and complete servicing and refixing the same after satisfactory repairs, reinstallation, testing and commissioning complete, all as specified and directed. |
| 125 | Material and labour for Calibration and complete repair of fuel injection pump of water heating plant of various capacity upto 2000 ltrs, on work bench for fine spray and machining work and refixing the same for satisfactory functioning, comlete, all as specified and directed. |
| 126 | Supply and fixing in replacement of nozzle of hot water plant as per existing size and testing after repairs, complete, all as specified and directed. |
| 127 | Supply and fixing in replacement pressure meter suitable for hot water generator as per existing size and testing after repairs, complete, all as specified and directed. |
| 128 | Supply and fixing in replacement fuel filter suitable for hot water generator as per existing size and testing after repairs, complete, all as specified and directed. |
| 129 | Supply and fixing in replacement solenoid switch for hot water generator as per existing size and testing after repairs, complete, all as specified and directed. |
| 130 | Dismentling of burner gasket suitable for hot water generator as per existing size and testing after repairs, complete, all as specified and directed. |
| 131 | Supply and fixing in replacement burner gasket suitable for hot water generator as per existing size and testing after repairs, complete, all as specified and directed. |
| 132 | Supply and fix in repair indicator assembly, complete all as specified |
| 133 | Supply and fix in repair bimetallic overload relay 4.0 - 6.5 Amps type ML complete all as specified |
| 134 | Supply and fix in repair electromagnetic rod combined with positive/ negative terminals suitable for hot water generator of any capacity as per existing size and testing after repairs complete |
| 135 | Supply and fixing in replacement photo censor suitable for hot water generator/plant as per existing size and testing after repairs, complete, all as specified and directed. |
| 136 | Supply and fixing in replacement Diesel/fuel pipe with internal and outer threads suitable for hot water generator/plant as per existing size and testing after repairs, complete, all as specified and directed. |
| 137 | Dismantling fuel tank of water heating plant, servicing, decarboning of complete water plant and reassembling the same after cleaning properly by removing all deposited particles, dust, carbon etc, complete, all as specified and directed. |
| 138 | Supply and fixing in replacement of new digital type electronic temperature gauge with thermostat control relay suitable for 2,00,000 K Cal/hr capacity hot water generator Complete all as specified. |
| 139 | Disconnecting and taking out burnt hot water plant blower motor, transporting to workshop, dismantling carefully, cutting out burnt windings, cleaning the slots and rewinding with super emamelled copper winding wire of appropriate gauge & weight incl all insulating materials, varnishing, drying, heating etc and incl replacement of ball bearings as per existing, reassembling and refixing at original site and testing, complete, all as specified and directed. |
| 140 | M&L for disconnectiong existing defective 500Ltr capacity Heating plant/ Hamam from electric mains, water mains and fuel pump isolating the necked connections, removing from foundation by unscrewing the nuts, bolts etc, discouple from pump and motor, opening of Heating plant/ Hamam and motor for inspection in presence of Engr-in-Charge and to carry out major repairs transporting to workshop and back, reassembling the Heating plant/ Hamam after repair, refixing in position reconnecting same as prior to removing from foundation including replacement of nuts, bolts washers of suitable size, testing and commissioning complete all as specified and directed.Disconnecting the Heating plant and remove the SS inner and outer tank carefully, carry to trade workshop for necessory repairs such as :-(a) Cut the rust out parts of 500 Ltr capacity Heating plant/ Hamam.(b) Moulding of inner tank of 500 Ltr capacity Heating plant/ Hamam and welding work. (c) Moulding of outer tank of 500 Ltr capacity Heating plant/ Hamam and welding work.(d) Supply and filling in replacement of Glass wool between the inner and outer tank.(e) Supply and fixing in replacement upper and lower aluminium strap for suitable size.(f) Supply and fixing in replace ment of necessory quanty and size of nut,bolt and washer.(g) Supply and fixing in replacement of Base plate of 500 Ltr capacity Heating plant/ Hamam of existing size with GI plate of minimum 5 mm thick.(h) Supply and fixing in repair of water connection arrangement of water Heating plant/Hamam i.e, Nipple,socket, reducer socket and Gate valve/ ball valve etc.(j) Repair/ replacement of Top and bottom cover.(k) Other miscellanious Repairs.(l) Supply and eplacement of inner (Dollaky) Plates 5 mm thick.(m) Supply and replacement of Vertical MS tubes size of 50 mm.Note :- (i) Replacement of defecting parts is included in the Quated rate. (ii) major repairs are not possible at site, the Heating plant/ Hamam shall be shifted to Civil workshop, and cost of shifting to workshop and back to site included in the rates. |
| 141 | Excavation in trenches n .exc 1.5 mtr wide and not exec 1.5 mtr depth and getting out in looses/soft soil complete all as specified |
| 142 | Returing filling in incl spreading leveling, watering and well ramming in layer not less than 25 cum each layer all as specified. |
| 143 | Removing excavated material to a distance not exc 50M and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified |
| 144 | M&L filling of dry sand under and around LT cable to provide sand cushioing and in sub stn ducts/trenches complete all as directed. |
| 145 | M/L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable complete all as specified and directed. |
| 146 | M&L PCC 1:4:8 type D 2 using 40 mm graded stone aggregate for foundation of pole complete all as directed |
| 147 | M&L PCC 1:3:6 type C 2 using 40 mm graded stone aggregate for filling of pole & stay complete all as directed |
| 148 | M&L PCC 1:2:4 type B2 using 20 mm graded stone aggregate for copiing of pole complete all as directed |
| 149 | Taking out old UNSV and Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete, all as specified and directed :- |
| 150 | (a) 25 Sqmm 4.0 Core. |
| 151 | (b) 16 Sqmm 4 core |
| 152 | Supply and fixing of MCCB 4P 100 Amps 16 KA capacity 415V 50Hz with adjustable thermal and fixed magnetic relay incl taking out the old unserviceable complete all as specified and directed by Engr-in-Charge. |
| 153 | Supply and installation of on load change over switch in sheet metal enclosure of capacity 100 Amps FP, 415 Vac, 50 Hz, complete all as specified and directed. |
| 154 | Taking down existng unserviceable street/security light fittings HPSV/HPMV/MH/Tube light fittinsgs of any capacity any type from pole/wall after disconnection the connecting wires and supply and fixing in replacement of integral LED street light luminaries complete comprising of epoxy powder coated housing, enclosed with glass cover in front 35 Watts made up of pressure die cast housing of IK07 with symmetrical light distribution all accessories complete suitable for 50 mm dia pipe in gress preotection IP-66 complete all as specified and directed by Engr-in-Charge. |
| 155 | Taking down existng unserviceable street/security light fittings HPSV/HPMV/MH/Tube light fittinsgs of any capacity any type from pole/wall after disconnection the connecting wires and supply and fixing in replacement of integral LED street light luminaries complete comprising of epoxy powder coated housing, enclosed with glass cover in front 60 Watts made up of pressure die cast housing of IK07 with symmetrical light distribution all accessories complete suitable for 50 mm dia pipe in gress preotection IP-66 complete all as specified and directed by Engr-in-Charge. |
| 156 | S & F in replacement of 120W LED flood light of die cast aluminium body, IP-66 including all accessories as required complete all as specified and as directed. |
| 157 | S & F in replacement of 210W LED flood light of die cast aluminium body, IP-66 including all accessories as required complete all as specified and as directed. |
| 158 | S&F in replacement of street light terminal boxes made out with SMC material, shock and dust proof of inside size 295x195x100 mm as per IS and including 100 amp TPN busbar fixed on insulators, 01 No 06 amp SP MCB, earth termination with nuts and bolts and including 02 sets of flat iron 25x6 mm clamps of suitable size with nuts,bolts and washers complete all as specified and as directed. |
| 159 | Taking out old unserviceable PCC/steel tubular pole 9 mtrs long and supply and fixing steel tubular swaged poles with cast iron base plate, finial taper plug, bolts, nuts, screws as specified type 410 SP-31 (9.0 mtr long) and erecting in position all as specified and directed with shifting of conductors and insulators including painting the exposed portion with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete, all as specified and directed. |
| 160 | Taking down and replacement of existing unserviceable street light fitting bracket with new brackets made out of 40mm bore GI pipe, light grade, tubing bend to shape, 1.2 metre long, fixed to pole/wall with and including two sets of clamps made out of flat iron of size 50 x 6 mm with bolts, nuts and washers, complete, all as specified and directed. |
| 161 | Taking down and replacement of existing unserviceable clamps with new clamps made out of 40x6 mm bending to shape, drilling holes for bolts suitable for fixing GI pipe bracket to steel pole, made in two halves, including nuts, bolts, washers and painting with two coats of aluminium paint over a coat of red oxide primer, complete, all as specified and directed. |
| 162 | M&L for painting steel tubular pole 9 mtrs long alongwith bends with two coats of aluminium paint over a coat of red oxide primer and internally through out plus embedded portion with two coats of black bituminous paint over a coat of red oxide primer with and including marking of pole number with black paint in yellow circle, complete, all as specified and directed. |
| 163 | Supply and laying pipe galvanized, “light grade” of size 50 MM to be used on road crossing/ culverts for laying of cable complete all as directed by Engr-in-Charge |
| 164 | S&F in repair of 1.5 sqmm 3 core pvc insulated flexible copper conductor wire from street light terminal box to fittings of required length drawn through and including PVC conduit of suitable size or as indicated and directed. |
| 165 | S&F in repair MCB SP 16 amp, 'C' curve, 10 KA, 240V complete inside existing postion of street light terminal boxes including taking down old unserviceable all as specified and as directed. |
| 166 | S&F in repair of 20 watt LED decorative post top light fitting of aesthetically designed with symmetrical light distrubution, IP-65, 230/240V, 50 Hz AC supply and with all accessories and incl lamp etc prewired |
| 167 | Notes :- Amount of Credit Schedule for Schedule 'A' Part-ll shall be deducted from total quoted amount of BOQ to arrive at the contract sum. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail